Accuracy of Nasal Cannula Pressure Recordings for Assessment of Ventilation during Sleep
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Nasal prong pressure monitoring (PNOSE) is utilized to assess ventilation during sleep. However, it has not been rigorously validated against the gold standard of face-mask pneumotachography (VFM). Therefore, we compared PNOSE with VFM in 20 patients with suspected sleep apnea during nocturnal polysomnography, and analyzed factors affecting accuracy of PNOSE-derived variables. Patients rated their nasal obstruction on a visual analog scale. Mean +/- SE apnea/hypopnea index (AHI) by VFM was 24.0 +/- 5.1 h(-1). The bias (mean difference) and limits of agreement (+/- 2 SD) of AHI derived from PNOSE, and square root-transformed PNOSE, a measure proposed as a surrogate of airflow, were +3.9 (+/- 4.6), and -0.9 (+/- 9.0) h(-1). Subjective scores of nasal obstruction before polysomnographies did not herald inaccuracy of AHI from PNOSE. Square root-transformed PNOSE closely tracked pneumotachographic airflow over 10 breaths (r(2) among signals 0.88 to 0.96) but the relationship among these signals was highly variable if comparisons were extended over an entire night. Compared with face-mask pneumotachography, nasal pressure monitoring provides accurate AHI for clinical purposes even in patients perceiving nasal obstruction. Square-root transformation provides near linear nasal pressure/airflow relationships over a short time but is not essential for estimation of AHI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973
Effects of Varying Approaches for Identifying Respiratory Disturbances on Sleep Apnea Assessment
REDLINE, S., KAPUR, V. K., SANDERS, M. H., QUAN, S. F., GOTTLIEB, D. J., RAPOPORT, D. M., BONEKAT, W. H., SMITH, P. L., KILEY, J. P., & IBER, C. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9904031 · Cited by 225
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study
Heinzer, R., Vat, S., Marques-Vidal, P., Marti-Soler, H., Andries, D., Tobback, N., Mooser, V, Preisig, M., Malhotra, A., Waeber, G., et al. (2015) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(15)00043-0 · Cited by 2,481
Khandoker, A. H., Palaniswami, M., & Karmakar, C. K. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2004495 · Cited by 367
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Sands, S. A., Edwards, B. A., Terrill, P. I., Taranto-Montemurro, L., Azarbarzin, A., Marques, M., Hess, L. B., White, D. P., & Wellman, A. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201707-1435oc · Cited by 291
“The nasal pressure signal was square-root transformed (9, 21, 22) to provide an uncalibrated surrogate of ventilatory flow that was then used to estimate the traits as described above.”
Method
Metadata
- Authors
- THURNHEER, R., XIE, X., & BLOCH, K. E.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-11-15
- Volume
- 164
- Issue
- 10
- Pages
- 1914-1919
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2130677855
- Cited by
- 133
- References
- 3
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Nasal Cannula Pressure Recordings for Assessment of Ventilation during Sleep. https://app.cochat.ai/papers/10.1164/ajrccm.164.10.2102104
- The paper
- THURNHEER, R., XIE, X., & BLOCH, K. E. (2001). Accuracy of Nasal Cannula Pressure Recordings for Assessment of Ventilation during Sleep. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.164.10.2102104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.