CoChat

Accuracy of Nasal Cannula Pressure Recordings for Assessment of Ventilation during Sleep

THURNHEER, ROBERT, XIE, XIAOBIN, BLOCH, KONRAD E. · 2001 · American Journal of Respiratory and Critical Care Medicine
Cited by 133

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Nasal prong pressure monitoring (PNOSE) is utilized to assess ventilation during sleep. However, it has not been rigorously validated against the gold standard of face-mask pneumotachography (VFM). Therefore, we compared PNOSE with VFM in 20 patients with suspected sleep apnea during nocturnal polysomnography, and analyzed factors affecting accuracy of PNOSE-derived variables. Patients rated their nasal obstruction on a visual analog scale. Mean +/- SE apnea/hypopnea index (AHI) by VFM was 24.0 +/- 5.1 h(-1). The bias (mean difference) and limits of agreement (+/- 2 SD) of AHI derived from PNOSE, and square root-transformed PNOSE, a measure proposed as a surrogate of airflow, were +3.9 (+/- 4.6), and -0.9 (+/- 9.0) h(-1). Subjective scores of nasal obstruction before polysomnographies did not herald inaccuracy of AHI from PNOSE. Square root-transformed PNOSE closely tracked pneumotachographic airflow over 10 breaths (r(2) among signals 0.88 to 0.96) but the relationship among these signals was highly variable if comparisons were extended over an entire night. Compared with face-mask pneumotachography, nasal pressure monitoring provides accurate AHI for clinical purposes even in patients perceiving nasal obstruction. Square-root transformation provides near linear nasal pressure/airflow relationships over a short time but is not essential for estimation of AHI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.164.10.2102104

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 133

Metadata

Authors
THURNHEER, R., XIE, X., & BLOCH, K. E.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2001-11-15
Volume
164
Issue
10
Pages
1914-1919
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2130677855
Cited by
133
References
3
FWCI
3.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Nasal Cannula Pressure Recordings for Assessment of Ventilation during Sleep. https://app.cochat.ai/papers/10.1164/ajrccm.164.10.2102104
The paper
THURNHEER, R., XIE, X., & BLOCH, K. E. (2001). Accuracy of Nasal Cannula Pressure Recordings for Assessment of Ventilation during Sleep. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.164.10.2102104

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.