The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Adaptive Pressure Support Servo-Ventilation: A Novel Treatment for Cheyne-Stokes Respiration in Heart Failure
Abstract
Adaptive servo-ventilation (ASV) is a novel method of ventilatory support designed for Cheyne-Stokes respiration (CSR) in heart failure. The aim of our study was to compare the effect of one night of ASV on sleep and breathing with the effect of other treatments. Fourteen subjects with stable cardiac failure and receiving optimal medical treatment were tested untreated and on four treatment nights in random order: nasal oxygen (2 L/min), continuous positive airway pressure (CPAP) (mean 9.25 cm H(2)O), bilevel (mean 13.5/5.2 cm H(2)O), or ASV largely at the default settings (mean pressure 7 to 9 cm H(2)O) during polysomnography. Thermistor apnea + hypopnea index (AHI) declined from 44.5 +/- 3.4/h (SEM) untreated to 28.2 +/- 3.4/h oxygen and 26.8 +/- 4.6/h CPAP (both p < 0.001 versus control), 14.8 +/- 2.3/h bilevel, and 6.3 +/- 0.9/h ASV (p < 0.001 versus bilevel). Effort band AHI behaved similarly. Arousal index decreased from 65.1 +/- 3.9/h untreated to 29.8 +/- 2.8/h oxygen and 29.9 +/- 3.2/h CPAP, to 16.0 +/- 1.3/h bilevel and 14.7 +/- 1.8/h ASV (p < 0.01 versus all except bilevel). There were large increases in slow-wave and rapid eye movement (REM) sleep with ASV but not with oxygen or CPAP. All subjects preferred ASV to CPAP. One night ASV suppresses central sleep apnea and/or CSR (CSA/CSR) in heart failure and improves sleep quality better than CPAP or 2 L/min oxygen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
Goldberger, J. J., Cain, M. E., Hohnloser, S. H., Kadish, A. H., Knight, B. P., Lauer, M. S., Maron, B. J., Page, R. L., Passman, R. S., Siscovick, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189375 · Cited by 1,450
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Ezekowitz, J. A., O'Meara, E., McDonald, M. A., Abrams, H., Chan, M., Ducharme, A., Giannetti, N., Grzeslo, A., Hamilton, P. G., Heckman, G. A., et al. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.08.022 · Cited by 676
Sleep Apnea and Cardiovascular Disease
LEUNG, R. S. T., & DOUGLAS BRADLEY, T. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.12.2107045 · Cited by 649
Metadata
- Authors
- TESCHLER, H., DÖHRING, J., WANG, Y.-M., & BERTHON-JONES, M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-08-15
- Volume
- 164
- Issue
- 4
- Pages
- 614-619
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1895423505
- Cited by
- 605
- References
- 1
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Pressure Support Servo-Ventilation: A Novel Treatment for Cheyne-Stokes Respiration in Heart Failure. https://app.cochat.ai/papers/10.1164/ajrccm.164.4.9908114
- The paper
- TESCHLER, H., DÖHRING, J., WANG, Y.-M., & BERTHON-JONES, M. (2001). Adaptive Pressure Support Servo-Ventilation: A Novel Treatment for Cheyne-Stokes Respiration in Heart Failure. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.164.4.9908114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.