Identification and Quantification of Apneas by Computer-based Analysis of Oxygen Saturation
The DOI matches its Crossref record.
Abstract
Manual detection and quantitation of apneas from an all-night polysomnogram is very time-consuming. Because SaO2 changes with virtually every apnea event, we reasoned that by identifying cyclical SaO2 changes, we could calculate (1) an apnea-hypopnea index that would correlate very well with the manually derived apnea-hypopnea index, and (2) the duration of apnea-hypopnea events. We developed a computer algorithm to scan and detect dips in SaO2 data digitally stored as a time series by computer throughout overnight studies. Desaturations detected by computer were compared with the events detected manually in 9 all-night polysomnograms from 6 patients with typical obstructive sleep apnea. Events detected by one method but not the other were subsequently verified to determine the overall number of apnea-hypopnea events present and to determine false positive and false negative rates for the 2 methods of detection. The total number of apneas was 4,008. Both methods agreed on 3,639 of them. Of 77 manually recorded apneas not detected by computer, 24 were subsequently discounted (manual false positives, 24 of 4,007 = 0.6%) and 53 confirmed (computer false negatives, 1.32%). Of 358 events not detected manually, 316 were confirmed (manual false negatives, 7.9%) and 42 discounted (computer false positives, 1.1%). Using the final manual scoring as the reference, the computer program detected apneas with a sensitivity of 97.9%, and the predictive value of a computer-detected event was 90.8%. For event duration, a regression was performed on 3,623 matched apneas-hypopnea events, giving a coefficient of r = 0.9431, p less than 10(-6).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 3
- Am Rev Respir Dis, 198, 592
- Sleep, 198, 263
- Methods Inf Med, 198, 198
Cited by
Predictors and prevalence of obstructive sleep apnoea and snoring in 1001 middle aged men.
Stradling, J. R., & Crosby, J. H. (1991) · Thorax · doi:10.1136/thx.46.2.85 · Cited by 640
Davies, R., & Stradling (1990) · European Respiratory Journal · doi:10.1183/09031936.93.03050509 · Cited by 523
Davies, R. J., Ali, N. J., & Stradling, J. R. (1992) · Thorax · doi:10.1136/thx.47.2.101 · Cited by 479
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R., Millman, R., Coppola, M., Fleetham, J., Murray, C. F., Iber, C., McCall, W. V., Nino-Murcia, G., Pressman, M., Sanders, M., et al. (1994) · Sleep · doi:10.1093/sleep/17.4.378 · Cited by 433
Neuroendocrine Dysfunction in Sleep Apnea: Reversal by Continuous Positive Airways Pressure Therapy*
GRUNSTEIN, R. R., HANDELSMAN, D. J., LAWRENCE, S. J., BLACKWELL, C., CATERSON, I. D., & SULLIVAN, C. E. (1989) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-68-2-352 · Cited by 302
Metadata
- Authors
- George, C. F., Millar, T. W., & Kryger, M. H.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-05
- Volume
- 137
- Issue
- 5
- Pages
- 1238-1240
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2014238002
- Cited by
- 59
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification and Quantification of Apneas by Computer-based Analysis of Oxygen Saturation. https://app.cochat.ai/papers/10.1164/ajrccm/137.5.1238
- The paper
- George, C. F., Millar, T. W., & Kryger, M. H. (1988). Identification and Quantification of Apneas by Computer-based Analysis of Oxygen Saturation. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/137.5.1238
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.