The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Respiratory Monitoring in the Intensive Care Unit
Abstract
Continuous monitoring of important respiratory indices has the potential for predicting catastrophes and providing an opportunity for the timely institution of lifesaving measures. Arterial oxygenation can be monitored noninvasively using oximetry or transcutaneous oxygen electrodes, while mixed venous oxygenation can be recorded continuously with modified pulmonary artery catheters. A satisfactory method of monitoring carbon dioxide tension does not exist. Measurements of respiratory drive can be obtained at the bedside, but their clinical usefulness remains unknown. Assessment of respiratory muscle strength is helpful in determining the need for mechanical ventilation, but a practical method of diagnosing respiratory muscle fatigue remains elusive. Measurement of thoracic compliance and detailed examination of the breathing pattern, i.e., tidal volume, respiratory frequency, and the pattern of rib cage-abdominal motion, are helpful in assessing abnormal pulmonary mechanics. The detailed information provided by respiratory monitoring can complement but not replace careful bedside examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ear oximetry during combined hypoxia and exercise
Smyth, R. J., D'Urzo, A. D., Slutsky, A. S., Galko, B. M., & Rebuck, A. S. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.2.716 · Cited by 80
Cited by
Yang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Self-citationRespiratory weakness is associated with limb weakness and delayed weaning in critical illness*
De Jonghe, B., Bastuji-Garin, S., Durand, M.-C., Malissin, I., Rodrigues, P., Cerf, C., Outin, H., & Sharshar, T. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000281450.01881.d8 · Cited by 554
Respiration rate monitoring methods: A review
AL‐Khalidi, F. Q., Saatchi, R., Burke, D., Elphick, H., & Tan, S. (2011) · Pediatric Pulmonology · doi:10.1002/ppul.21416 · Cited by 536
Critical review of non-invasive respiratory monitoring in medical care
Folke, M., Cernerud, L., Ekström, M., & Hök, B. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348078 · Cited by 430
Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV
Di mussi, R., Spadaro, S., Mirabella, L., Volta, C. A., Serio, G., Staffieri, F., Dambrosio, M., Cinnella, G., Bruno, F., & Grasso, S. (2016) · Critical Care · doi:10.1186/s13054-015-1178-0 · Cited by 404
Metadata
- Authors
- Tobin, M. J.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-12
- Volume
- 138
- Issue
- 6
- Pages
- 1625-1642
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1987361444
- Cited by
- 200
- References
- 1
- FWCI
- 18.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiratory Monitoring in the Intensive Care Unit. https://app.cochat.ai/papers/10.1164/ajrccm/138.6.1625
- The paper
- Tobin, M. J. (1988). Respiratory Monitoring in the Intensive Care Unit. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/138.6.1625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.