The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Respiration rate monitoring methods: A review
Abstract
Respiration rate is an important indicator of a person's health, and thus it is monitored when performing clinical evaluations. There are different approaches for respiration monitoring, but generally they can be classed as contact or noncontact. For contact methods, the sensing device (or part of the instrument containing it) is attached to the subject's body. For noncontact approaches the monitoring is performed by an instrument that does not make any contact with the subject. In this article a review of respiration monitoring approaches (both contact and noncontact) is provided. Concerns related to the patient's recording comfort, recording hygiene, and the accuracy of respiration rate monitoring have resulted in the development of a number of noncontact respiration monitoring approaches. A description of thermal imaging based and vision based noncontact respiration monitoring approaches we are currently developing is provided. Pediatr. Pulmonol. 2011; 46:523–529. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subbe, C. P., Davies, R. G., Williams, E., Rutherford, P., & Gemmell, L. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03258.x · Cited by 446
Critical review of non-invasive respiratory monitoring in medical care
Folke, M., Cernerud, L., Ekström, M., & Hök, B. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348078 · Cited by 430
Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.
Fieselmann, J. F., Hendryx, M. S., Helms, C. M., & Wakefield, D. S. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600071 · Cited by 399
Goldhill, D. R., McNarry, A. F., Mandersloot, G., & McGinley, A. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04186.x · Cited by 304
The objective medical emergency team activation criteria: A case–control study
Cretikos, M., Chen, J., Hillman, K., Bellomo, R., Finfer, S., & Flabouris, A. (2007) · Resuscitation · doi:10.1016/j.resuscitation.2006.08.020 · Cited by 255
Breathing Detection: Towards a Miniaturized, Wearable, Battery-Operated Monitoring System
Corbishley, P., & Rodriguez-Villegas, E. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.910679 · Cited by 221
Respiratory Monitoring in the Intensive Care Unit
Tobin, M. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1625 · Cited by 200
Radar sensing of heartbeat and respiration at a distance with applications of the technology
Greneker, E. F. (1997) · doi:10.1049/cp:19971650 · Cited by 149
Real-time vision based respiration monitoring system
Tan, K. S., Saatchi, R., Elphick, H., & Burke, D. (2010) · International Symposium on Communication Systems, Networks and Digital Signal Processing (CSNDSP) · doi:10.1109/csndsp16145.2010.5580316 · Cited by 123
Self-citationA comparison of algorithms for estimation of a respiratory signal from the surface electrocardiogram
O’Brien, C., & Heneghan, C. (2006) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2006.02.002 · Cited by 118
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
A Survey of Healthcare Internet of Things (HIoT): A Clinical Perspective
Habibzadeh, H., Dinesh, K., Rajabi Shishvan, O., Boggio-Dandry, A., Sharma, G., & Soyata, T. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2946359 · Cited by 417
Metadata
- Authors
- AL‐Khalidi, F. Q., Saatchi, R., Burke, D., Elphick, H., & Tan, S.
- Venue
- Pediatric Pulmonology
- Publisher
- Wiley
- Published
- 2011-01-31
- Volume
- 46
- Issue
- 6
- Pages
- 523-529
- ISSN
- 1099-0496 (ISSN-L)
- 8755-6863
- OpenAlex
- W2078934723
- Cited by
- 536
- References
- 24
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Respiration rate monitoring methods: A review. https://app.cochat.ai/papers/10.1002/ppul.21416
- The paper
- AL‐Khalidi, F. Q., Saatchi, R., Burke, D., Elphick, H., & Tan, S. (2011). Respiration rate monitoring methods: A review. Pediatric Pulmonology. https://doi.org/10.1002/ppul.21416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.