Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record.

Clearing the Air: The Theory and Application of Ultraviolet Air Disinfection

Riley, Richard L., Nardell, Edward A.·1989·American Review of Respiratory Disease

Abstract

Abstract In the 1940s and 1950s, both the potential and the problems of interrupting transmission of airborne infection with ultraviolet (UV) light were demonstrated. William F. Wells first introduced the concept of droplet nuclei as the vehicles of airborne transmission and later showed that these nearly naked, suspended organisms were highly susceptible to inactivation by UV light of 254 nm wavelength (1, 2). Of the many infectious organisms that are susceptible to UV, most attention has been focused on measles and tuberculosis (TB) because of their importance as airborne infections and because each has characteristics favorable for epidemiologic study. In his classic experiment of 1942, Wells used UV light in schools to prevent the epidemic spread of measles (3). However, the inability of others to repeat Wells' success led to disillusionment (4, 5). Antiultraviolet sentiment was further fueled by concern about ozone production (negligible with current 254 nm wavelength bulbs) and by concerns about skin and eye irritation. The hope that chemotherapy would eradicate TB and that immunization would control most contagious viral illnesses may have also contributed to the near abandonment of UV. However, more than 40 years after the introduction of streptomycin, TB remains a worldwide problem and is increasing among certain populations in the United States and elsewhere, primarily in association with the acquired immunodeficiency syndrome (AIDS) (6). Reports of TB transmission among the elderly in nursing homes and among the homeless in shelters have reminded us of the potential for spread of this disease in these and other indoor environments. Less well documented, but of potential importance, is the transmission of TB and other airborne infections in jails, prisons, hospital intensive care units, and rooms used for bronchoscopy, sputum induction, and aerosol therapy with pentamidine and other agents (7–10). Close living situations like shelters and jails defy adequate control by conventional measures, but they may be benefited by UV air disinfection (11). Years after the introduction of an effective vaccine, measles still occurs, and in this country, transmission is increasingly associated with health care facilities (12). The ongoing need for improved control of person-to-person airborne transmission of some respiratory infections, our increasing reliance on recirculated air, and our growing understanding of where UV air disinfection is likely to work have prompted this review. Because UV must be properly planned and installed to be effective and safe, we will deal first with the theoretic and technical aspects, then we will deal with the selection of settings where we believe air disinfection should find application.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/139.5.1286

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Riley, R. L., & Nardell, E. A.
Venue
American Review of Respiratory Disease
Published
1989-05
Volume
139
Issue
5
Pages
1286-1294
ISSN
0003-0805 (ISSN-L)
OpenAlex
W2054325571
Cited by
204
References
0
FWCI
8.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clearing the Air: The Theory and Application of Ultraviolet Air Disinfection. https://app.cochat.ai/papers/10.1164/ajrccm/139.5.1286
The paper
Riley, R. L., & Nardell, E. A. (1989). Clearing the Air: The Theory and Application of Ultraviolet Air Disinfection. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/139.5.1286

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.