CoChat

The Acute Administration of Vasodilators in Primary Pulmonary Hypertension: Experience from the National Institutes of Health Registry on Primary Pulmonary Hypertension

Weir, E. Kenneth, Rubin, Lewis J., Ayres, Stephen M., Bergofsky, Edward H., Brundage, Bruce H., Detre, Katherine M., Elliott, C. Gregory, Fishman, Alfred P., Goldring, Roberta M., Groves, Bertron M., Kernis, Janet T., Koerner, Spencer K., Levy, Paul S., Pietra, Giuseppe G., Reid, Lynne M., Rich, Stuart, Vreim, Carol E., Williams, George W., Wu, Margaret · 1989 · American Review of Respiratory Disease
Cited by 186

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The hemodynamic responses to acute vasodilator administration were evaluated in 163 patients who were entered into the National Institutes of Health Registry on Primary Pulmonary Hypertension (PPH) between 1981 and 1985. Of a total of 491 drug administrations in these patients, 135 administrations in 104 patients were performed in a manner acceptable to the Registry. A single vasodilator was tried in 79 patients and more than one vasodilator in 25 patients. Two-thirds of the patients were in New York Heart Association Functional Classes III or IV. When the effects of all vasodilators were grouped together, there were significant decreases from baseline in mean pulmonary artery pressure (60 +/- 2 to 57 +/- 2 mm Hg, p less than 0.05) and total pulmonary resistance index (32.5 +/- 1.7 to 25.1 +/- 1.4 mm Hg/L/min/m2, p less than 0.0001), and increases in cardiac index (2.1 +/- 0.1 to 2.7 +/- 0.1 L/min/m2, p less than 0.0001). Mean systemic blood pressure fell (88 +/- 1 to 79 +/- 1 mm Hg, p less than 0.0001), whereas PaO2 was unchanged (70 +/- 3 to 71 +/- 3 mm Hg, p = NS). A fall in total pulmonary resistance greater than 20% was observed in 55% of the adequate drug trials. Adverse effects occurred in 32 of the total 491 patient-drug trials and were generally minor. Hypotension requiring treatment developed in six patients. There were two deaths attributable to vasodilator administration. Patients who died or had hypotension requiring treatment had higher right atrial pressures than did other treated patients (15 +/- 2 versus 9 +/- 1 mm Hg, p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/140.6.1623

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Weir, E. K., Rubin, L. J., Ayres, S. M., Bergofsky, E. H., Brundage, B. H., Detre, K. M., Elliott, C. G., Fishman, A. P., Goldring, R. M., Groves, B. M., Kernis, J. T., Koerner, S. K., Levy, P. S., Pietra, G. G., Reid, L. M., Rich, S., Vreim, C. E., Williams, G. W., & Wu, M.
Venue
American Review of Respiratory Disease
Published
1989-12
Volume
140
Issue
6
Pages
1623-1630
ISSN
0003-0805 (ISSN-L)
OpenAlex
W2043340154
Cited by
186
References
5
FWCI
8.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.