Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation

Nardell, Edward A., Keegan, Joann, Cheney, Sally A., Etkind, Sue C.·1991·American Review of Respiratory Disease

Abstract

Of 67 office workers 27 (40%) had documented tuberculin skin test conversions after an estimated 4-wk exposure to a coworker with cavitary tuberculosis. Worker complaints for more than 2 yr before the tuberculosis exposure prompted investigations of air quality in the building before and after the tuberculosis exposure. Carbon dioxide concentrations in many parts of the building were found to be above recommended levels, indicating suboptimal ventilation with outdoor air. We applied a mathematical model of airborne transmission to the data to assess the role of building ventilation and other transmission factors. We estimated that ventilation with outside air averaged about 15 feet 3/min (cfm) per occupant, the low end of acceptable ventilation, corresponding to CO2 levels of about 1,000 ppm. The model predicted that at 25 cfm per person 18 workers would have been infected (a 33% reduction) and at 35 cfm, a level considered optimal for comfort, that 13 workers would have been infected (an additional 19% reduction). Further increases in outdoor air ventilation would be impractical and would have resulted in progressively smaller increments in protection. According to the model, the index case added approximately 13 infectious doses (quanta) per hour (qph) to the office air during the exposure period, 10 times the average infectiousness reported in a large series of tuberculosis cases. Further modeling predicted that as infectiousness rises, ventilation would offer progressively less protection. We conclude that outdoor air ventilation that is inadequate for comfort may contribute to airborne infection but that the protection afforded to building occupants by ventilation above comfort levels may be inherently limited, especially when the level of exposure to infection is high.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm/144.2.302

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 261

Metadata

Authors
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C.
Venue
American Review of Respiratory Disease
Published
1991-08
Volume
144
Issue
2
Pages
302-306
ISSN
0003-0805 (ISSN-L)
OpenAlex
W1972169995
Cited by
261
References
7
FWCI
6.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation. https://app.cochat.ai/papers/10.1164/ajrccm/144.2.302
The paper
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991). Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/144.2.302

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.