Cited by 876Indoor Air Quality and Microbial ExposureInfection Control and VentilationBuilding Energy and Comfort Optimization

Association of ventilation rates and CO2 concentrations with health andother responses in commercial and institutional buildings

Open access
Seppanen, O. A., Fisk, W. J., Mendell, M. J.·1999·Indoor Air

Abstract

This paper reviews current literature on the associations of ventilation rates and carbon dioxide concentrations in non-residential and non-industrial buildings (primarily offices) with health and other human outcomes. Twenty studies, with close to 30,000 subjects, investigated the association of ventilation rates with human responses, and 21 studies, with over 30,000 subjects, investigated the association of carbon dioxide concentration with these responses. Almost all studies found that ventilation rates below 10 Ls-1 per person in all building types were associated with statistically significant worsening in one or more health or perceived air quality outcomes. Some studies determined that increases in ventilation rates above 10 Ls-1 per person, up to approximately 20 Ls-1 per person, were associated with further significant decreases in the prevalence of sick building syndrome (SBS) symptoms or with further significant improvements in perceived air quality. The carbon dioxide studies support these findings. About half of the carbon dioxide studies suggest that the risk of sick building syndrome symptoms continued to decrease significantly with decreasing carbon dioxide concentrations below 800 ppm. The ventilation studies reported relative risks of 1.5-2 for respiratory illnesses and 1.1-6 for sick building syndrome symptoms for low compared to high low ventilation rates.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.1999.00003.x

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 64 references couldn’t be matched to a known paper.

Research works printed but not linked: 29

  1. [1]1. ACGIH (1991) Documentation of the Threshold Limit Values and Biological Exposure Indices, Sixth Edition, Cincinnati, OH, American Conference of Governmental Industrial Hygien- ists.
  2. [3]3. Yoshizawa, S., Kimura, K., Ikeda, K., Tanabe, S. and Iwata, T. (eds) Proceedings of Indoor Air '96, Nagoya, 7th International Conference on Indoor Air Quality and Climate, Vol. 2, pp. 895-900.
  3. [14]14. Brightman, H.S., Wallace, L.A., Sieber, W.K., McCarthy, J.F. and Spengler, J.D. (1999) ''Comparing symptoms in United States office buildings''. In: Proceedings of Indoor Air '99, Lon- don, Construction Research Communications, Vol. 1, pp. 847-852.
  4. [19]19. Cochet, C., Ribe ´ron, J. and Kirchner, S. (1995) ''Reported symp- toms, ventilation performance and building characteristics in six French office buildings''. In: Maroni, M. (ed) Proceed- ings of Healthy Buildings '95, Milan, Vol. 3, pp. 1359-1364.
  5. [23]23. Emmerich, S. and Persily, A. (1999) ''Energy impacts of infil- tration and ventilation in U.S. office buildings using multi- zone airflow simulation''. In: Proceedings of IAQ '98, Atlanta, GA, American Society of Heating, Refrigerating and Air Conditioning Engineers, pp. 191-203.
  6. [25]25. Fanger, P.O. and Berg-Munch, B. (1983) ''Ventilation and body odor''. In: Proceedings of Management of Atmospheres in Tightly Enclosed Spaces, Atlanta, GA, American Society of Heating, Refrigerating and Air Conditioning Engineers, pp. 45-50.
  7. [30]30. Gamble, J., Morey, P., Richards, T., Petersen, M. and Castellan, R. (1986) ''Building-related respiratory symptoms: problems in identification''. In: Proceedings of IAQ '86, Atlanta, GA, American Society of Heating, Refrigerating and Air Con- ditioning Engineers, pp. 16-30.
  8. [31]31. Groes, L. (1995) ''The European IAQ-audit project, Statistical analysis of indoor environmental factors'', Ph.D. thesis, Lab- oratory of Heating and Air Conditioning, Technical Univer- sity of Denmark.
  9. [33]33. Hall, J., Mudarri, D. and Werling, E. (1998) ''Energy impacts of indoor environmental quality modifications to energy ef- ficiency projects''. In: Proceedings of IAQ '98, Atlanta, GA, American Society of Heating, Refrigerating and Air Con- ditioning Engineers, pp. 171-179.
  10. [36]36. Hodgson, M.J. and Collopy, P. (1989) ''Symptoms and the micro-environment in the sick building syndrome: A pilot study''. In: Proceedings of IAQ '89, Atlanta, GA, American Society of Heating, Refrigerating and Air Conditioning Engineers, pp. 8-16.
  11. [44]44. Janssen, J., Wolff, A. (1986) ''Subjective response to venti- lation''. In: Proceedings of IAQ '86, Atlanta, GA, American Society of Heating, Refrigerating and Air Conditioning Engineers, pp. 161-170.
  12. [47]47. Marmot, A.F., Eley J., Nguyen, M., Warwick, E. and Marmot, M.G. (1997) ''Building health in Whitehall: An epidemio- logical study of causes of SBS in 6,831 civil servants''. In: Pro- ceedings of Healthy Buildings '97, Washington, DC, Vol. 2, pp. 483-488.
  13. [48]48. Mendell, M.J. (1993a) ''Optimizing research on office worker symptoms: Recommendations from a critical review of the literature''. In: Proceedings of Indoor Air '93, Helsinki, Vol. 1, pp. 713-720.
  14. [50]50. Menzies, D. and Bourbeau, J. (1997) ''Building related ill- nesses'', The New England Journal of Medicine, 337, 1524-1531.
  15. [53]53. Menzies, D., Tamblyn, R.M., Nunes, F., Leduc, J., Pasztor, J. and Tamblyn, R.T. (1993b) ''Varying ventilation conditions to provide a more complete assessment of building HVAC op- eration and indoor air quality''. In: Proceedings of Indoor Air '93, Helsinki, Vol. 6, pp. 551-556,
  16. [54]54. Milton, D., Glencross, P. and Walters, M. (1998) ''Illness related work absence associated with workplace ventilation and hu- midification'', American Journal of Respiratory Critical Care Medicine, 157, A647.
  17. [55]55. Milton, D., Glencross, P. and Walters, M. (1999) ''Risk of sick leave associated with outdoor ventilation level, humidifi- cation, and building related complaints'', Cambridge, MA, Harvard School of Public Health.
  18. [57]57. Myhrvold, A., Olesen, E. and Lauridsen, O. (1996) ''Indoor en- vironment in schools -pupils health and performance in re- gard to CO 2 concentrations''. In: Yoshizawa, S., Kimura, K., Ikeda, K., Tanabe, S. and Iwata, T. (eds) Proceedings of Indoor Air '96, Nagoya, 7th International Conference on Indoor Air Quality and Climate, Vol. 4, pp. 369-374.
  19. [58]58. Nagda, N.L., Koontz, M.D. and Albrecht, R.J. (1991) ''Effect of ventilation rate in a healthy building''. Proceedings of IAQ '91, Atlanta, GA, American Society of Heating, Refrigerating and Air Conditioning Engineers, pp. 101-107.
  20. [59]59. Nagda, N., Koontz, M., Lumby, D., Albrecht, R. and Rizzuto, J. (1990), ''Impact of increased ventilation rates on office build- ing air quality''. In: Proceedings of Indoor Air '90, Ottawa, In- ternational Conference on Indoor Air Quality and Climate, Vol. 1, pp. 281-286.
  21. [61]61. Nardell, E.A. (1997) ''Environmental control of drug resistant tuberculosis in industrial and developing countries''. In: Pro- ceedings of Healthy Buildings '97, Washington, DC, Vol. 1, pp. 301-313.
  22. [63]63. Nelson, C.J., Calyton, C.A., Wallace, L.A., Highsmith, V.R., Kol- lander, M., Bascom, R. and Leaderer, B.P. (1991) ''EPA's in- door air quality and work environment survey: relation- ships of employee's self-reported health symptoms with di- rect indoor air quality measurements''. In: Proceedings of IAQ '91, Atlanta, GA, American Society of Heating, Refrigerating and Air Conditioning Engineers, pp. 14-21.
  23. [69]69. Palonen, J. and Seppa ¨nen, O. (1990) ''Design criteria for central ventilation and air-conditioning system of offices in cold cli- mate''. In: Proceedings of Indoor Air '90, Ottawa, International Conference on Indoor Air Quality and Climate, Vol. 1, pp. 299-304.
  24. [70]70. Persily, A. (1997) ''Evaluating building IAQ and ventilation with indoor carbon dioxide'', ASHRAE Transactions, 103, 1- 12.
  25. [72]72. Persily, A. and Dols, W.S. (1990) ''The relation of CO 2 concen- tration to office building ventilation'', ASTM Special Techni- cal Publication 1067-1990, West Conshohocken, PA, Ameri- can Society for Testing and Materials, pp. 77-91.
  26. [74]74. Roulet, C., Bluyssen, P., Ducarme, D., de Oliveira Fernandes, E., Ribedon, J. and Wouters, P. (1995) ''Ventilation perform- ance and energy consumption in European office build- ings''. In: Proceedings of 4th International conference on Healthy Buildings, pp. 1299-1304.
  27. [78]78. Sieber, W., Wallingford, K. and Allen, J. (1998) ''Carbon dioxide levels in the indoor office environment'', Proceedings of the Section of Statistics and the Environment, Dallas, TX, American Statistical Association, pp. 115-117.
  28. [81]81. Sohn, J-Y., Park, J-S., Park, B-Y., Yoon, D-W. and Minamino, O. (1994) ''Experimental research on the indoor air quality and sick building syndrome in office buildings''. In: Banhidi, L., Farkas, I., Magyar, Z. and Rudnai, P. (eds) Proceedings of Healthy Buildings '94, Budapest, pp. 397-406.
  29. [91]91. WHO (1983) Indoor pollutants: exposure and health effects, re- port of a WHO meeting, Copenhagen, World Health Organ- ization Regional Office for Europe. EURO Reports and Studies No. 78. Wu, X. and Wang, G-H. (1996) Fresh air make up, air distri- bution principle, and sick building syndrome. In: Yoshiza- wa, S., Kimura, K., Ikeda, K., Tanabe, S. and Iwata, T. (eds) Proceedings of Indoor Air '96, Nagoya, 7th International Con- ference on Indoor Air Quality and Climate, Vol. 2, pp. 919- 922.

Cited by

Sorted by citations

Authors
Seppanen, O. A., Fisk, W. J., & Mendell, M. J.
Affiliations
  • Lawrence Berkeley National Laboratory (US)
  • National Institute for Occupational Safety and Health (US)
Corresponding author
Fisk, W. J.
Venue
Indoor Air
Published
1999-12
Volume
9
Issue
4
Pages
226-252
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2161463298
Cited by
876
References
64
Citations by year
2026: 41 · 2025: 45 · 2024: 36 · 2023: 46 · 2022: 48 · 2021: 53 · 2020: 74 · 2019: 56 · 2018: 45 · 2017: 32 · 2016: 31 · 2015: 52 · 2014: 51 · 2013: 29 · 2012: 38
FWCI
2.63
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion)
  • PubMed (publishedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, public-domain)
Funders
U.S. Department of Energy (DE-AC03-?, AC03-76SF00098, DEAC03-76SF00098)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
ventilation rate, CO2 concentration, sick building syndrome, office buildings, institutional building, perceived air quality, respiratory diseases, indoor air quality, occupant health
MeSH terms
Adult, Carbon Dioxide, Humans, Public Health, Incidence, Occupational Health, Air Pollution, Indoor, Risk Assessment, Sick Building Syndrome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review