The DOI matches its Crossref record.
Oxygen Consumption Is Independent of Increases in Oxygen Delivery by Dobutamine in Septic Patients Who Have Normal or Increased Plasma Lactate
Abstract
We asked whether the relationship between oxygen delivery and oxygen consumption is different between patients who have sepsis and normal (n = 6) or increased (n = 8) concentrations of plasma lactate. We determined oxygen consumption using analysis of respiratory gases while increasing oxygen delivery using a dobutamine infusion. The relationship between oxygen delivery and consumption was y = 124 + 0.043 * x in the normal lactate group and y = 131 - 0.003 * x in the high lactate group (95% CI for differences in slopes, -0.003 to 0.096; p < or = 0.05 for slope, normal versus high lactate). In the normal lactate group, direct oxygen consumption increased by only 8 +/- 6 ml/min/m2 after dobutamine infusion (from 144 +/- 26 to 153 +/- 22 ml/min/m2, p < or = 0.02) despite an average increase of 220 +/- 80 ml/min/m2 in oxygen delivery (from 446 +/- 91 to 666 +/- 90 ml/min/m2, p < or = 0.01). The oxygen extraction ratio fell from 0.27 +/- 0.03 to 0.21 +/- 0.02 after dobutamine (p < or = 0.017). In the high lactate group, direct oxygen consumption decreased by 1 +/- 6 ml/min/m2 after dobutamine (from 131 +/- 33 to 130 +/- 35 ml/min/m2, p > 0.60) despite an average increase of 168 +/- 138 ml/min/m2 in oxygen delivery (from 467 +/- 194 to 635 +/- 300 ml/min/m2, p < or = 0.01). The oxygen extraction ratio fell from 0.30 +/- 0.14 to 0.26 +/- 0.12 after dobutamine (p < or = 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effect of Stored-Blood Transfusion on Oxygen Delivery in Patients With Sepsis
Marik, P. E. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500230106037 · Cited by 812
Effects of perfusion pressure on tissue perfusion in septic shock.
LeDoux, D., Astiz, M. E., Carpati, C. M., & Rackow, E. C. (2000) · Critical Care Medicine · doi:10.1097/00003246-200008000-00007 · Cited by 586
Multiple Organ Failure Syndrome in the 1990s: Systemic Inflammatory Response and Organ Dysfunction
Beal, A. L. (1994) · JAMA · doi:10.1001/jama.1994.03510270072043 · Cited by 530
Sepsis-associated hyperlactatemia
Garcia-Alvarez, M., Marik, P., & Bellomo, R. (2014) · Critical Care · doi:10.1186/s13054-014-0503-3 · Cited by 506
Practice parameters for hemodynamic support of sepsis in adult patients in sepsis
(1999) · Critical Care Medicine · doi:10.1097/00003246-199903000-00049 · Cited by 438
Metadata
- Authors
- Ronco, J. J., Fenwick, J. C., Wiggs, B. R., Phang, P. T., Russell, J. A., & Tweeddale, M. G.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01
- Volume
- 147
- Issue
- 1
- Pages
- 25-31
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1972752233
- Cited by
- 176
- References
- 0
- FWCI
- 23.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen Consumption Is Independent of Increases in Oxygen Delivery by Dobutamine in Septic Patients Who Have Normal or Increased Plasma Lactate. https://app.cochat.ai/papers/10.1164/ajrccm/147.1.25
- The paper
- Ronco, J. J., Fenwick, J. C., Wiggs, B. R., Phang, P. T., Russell, J. A., & Tweeddale, M. G. (1993). Oxygen Consumption Is Independent of Increases in Oxygen Delivery by Dobutamine in Septic Patients Who Have Normal or Increased Plasma Lactate. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/147.1.25
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.