The DOI matches its Crossref record.
A Comparison of Clinical Assessment and Home Oximetry in the Diagnosis of Obstructive Sleep Apnea
Abstract
In order to determine whether measurement of arterial oxygen saturation (SaO2) could identify patients with obstructive sleep apnea (OSA), 98 consecutive patients referred for assessment of snoring and/or daytime somnolence were assessed clinically and then underwent both unsupervised oximetry in their homes and formal polysomnography. Clinical assessment identified patients with an apnea+hypopnea index (AHI) > or = 15 events per hour with a sensitivity of 79% and a specificity of 50%. Home oximetry analyzed by counting the number of arterial oxygen desaturations recorded was inferior to clinical assessment. For desaturations of 2% or more from baseline, desaturation index (DI) > or = 15 per hour identified patients with AHI > or = 15 with sensitivity 65% and specificity 74%; for 3% desaturations, sensitivity was 51% and specificity 90%; and for 4% desaturations, sensitivity was 40% and specificity 98%. From the oximetry data, the percentage of time spent at SaO2 below 90% (CT90) was also calculated. CT90 > or = 1% identified patients with AHI > or = 15 with sensitivity 93% and specificity 51%; for patients with AHI > or = 15 ultimately given nasal continuous positive airway pressure (CPAP), the sensitivity of a CT90 > or = 1% was 100%. We concluded that home oximetry with CT90 < 1% practically excludes clinically significant OSA. Conversely, home oximetry with DI > or = 15 for 4% desaturations makes OSA likely: the positive predictive value for OSA is 83% if the pretest probability of OSA is 30% and over 90% if the pretest probability is at least 50%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects
Isono, S., Remmers, J. E., Tanaka, A., Sho, Y., Sato, J., & Nishino, T. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1319 · Cited by 534
Pulmonary Complications of Obesity
Koenig, S. M. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200104000-00006 · Cited by 530
Likelihood ratios for a sleep apnea clinical prediction rule.
Flemons, W. W., Whitelaw, W. A., Brant, R., & Remmers, J. E. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.5.7952553 · Cited by 472
Portable Recording in the Assessment of Obstructive Sleep Apnea
Ferber, R., Millman, R., Coppola, M., Fleetham, J., Murray, C. F., Iber, C., McCall, W. V., Nino-Murcia, G., Pressman, M., Sanders, M., et al. (1994) · Sleep · doi:10.1093/sleep/17.4.378 · Cited by 433
Metadata
- Authors
- Gyulay, S., Olson, L. G., Hensley, M. J., King, M. T., Allen, K. M., & Saunders, N. A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01
- Volume
- 147
- Issue
- 1
- Pages
- 50-53
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1992776121
- Cited by
- 209
- References
- 0
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison of Clinical Assessment and Home Oximetry in the Diagnosis of Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm/147.1.50
- The paper
- Gyulay, S., Olson, L. G., Hensley, M. J., King, M. T., Allen, K. M., & Saunders, N. A. (1993). A Comparison of Clinical Assessment and Home Oximetry in the Diagnosis of Obstructive Sleep Apnea. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/147.1.50
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.