The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Effect of Anterior Mandibular Positioning on Obstructive Sleep Apnea
Abstract
This prospective case report series utilized an anterior mandibular positioning (AMP) device on obstructive sleep apnea (OSA) patients and evaluated the changes in the respiratory disturbance index (RDI) and subjective overall satisfaction with the treatment. The RDI was based on all-night polysomnographic studies performed before and after approximately 4 months of appliance use. Overall satisfaction with the treatment was rated using a Likert scale (0 to 10) after 6, 18, and 36 months of AMP device use. Although only 15 of the 24 subjects agreed to undergo post-appliance polysomnograms, 14 of the 15 subjects showed a clear decrease in the RDI. The effect on the other subjects is unknown, but even if the 9 subjects without polysomnograms had no change in the RDI from the AMP device, a minimum rate of 58% of the subjects (14 of 24) would have substantially improved the RDI at the 3-month time point. Of the 24 subjects, 2 subjects claimed no immediate benefit and stopped using the device, 4 subjects were lost to followup, 1 subject lost weight and stopped using the device, 1 subject had mandibular advancement surgery after using the appliance for a period of time, and 3 stopped using the appliance because of persistent temporomandibular pain problems. The remaining 12 of the 23 (52%) original subjects were still using the appliance successfully at 36 months. One subject died of non-apnea-related causes before the 18-month follow-up time point. The 16 subjects who responded at 36 months reported a mean overall satisfaction with treatment of 6.9 +/- 3.3 on a scale of 10.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Sleep position training as treatment for sleep apnea syndrome: a preliminary study
Cartwright, R. D., Lloyd, S., Lilie, J., & Kravitz, H. (1985) · Sleep · doi:10.1093/sleep/8.2.87 · Cited by 171
Cited by
Strollo, P. J., & Rogers, R. M. (1996) · New England Journal of Medicine · doi:10.1056/nejm199601113340207 · Cited by 1,313
Oral Appliances for the Treatment of Snoring and Obstructive Sleep Apnea: A Review
Schmidt-Nowara, W., Lowe, A., Wiegand, L., Cartwright, R., Perez-Guerra, F., & Menn, S. (1995) · Sleep · doi:10.1093/sleep/18.6.501 · Cited by 543
A Randomized, Controlled Study of a Mandibular Advancement Splint for Obstructive Sleep Apnea
MEHTA, A., QIAN, J., PETOCZ, P., DARENDELILER, M. A., & CISTULLI, P. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004213 · Cited by 514
Ferguson, K. A., Ono, T., Lowe, A. A., Keenan, S. P., & Fleetham, J. A. (1996) · Chest · doi:10.1378/chest.109.5.1269 · Cited by 495
Positional vs Nonpositional Obstructive Sleep Apnea Patients
Oksenberg, A., Arons, E., Radwan, H., & Silverberg, D. S. (1997) · Chest · doi:10.1378/chest.112.3.629 · Cited by 441
Metadata
- Authors
- Clark, G. T., Arand, D., Chung, E., & Tong, D.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-03
- Volume
- 147
- Issue
- 3
- Pages
- 624-629
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2080403422
- Cited by
- 212
- References
- 2
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Anterior Mandibular Positioning on Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm/147.3.624
- The paper
- Clark, G. T., Arand, D., Chung, E., & Tong, D. (1993). Effect of Anterior Mandibular Positioning on Obstructive Sleep Apnea. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/147.3.624
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.