Determinants of Continuous Positive Airway Pressure Level for Treatment of Obstructive Sleep Apnea
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The purpose of this study was (1) to examine the factors that account for the variability in continuous positive airway pressure (CPAP) levels required to abolish obstructive sleep apnea (OSA) in patients with this disorder, and (2) to examine the feasibility of predicting the lowest effective pressure (CPAPmin) from simple anthropometric and polysomnographic variables easily available in all patients considered for home CPAP therapy. To accomplish these tasks we studied a group of 208 patients with OSA all of whom were treated with nasal CPAP at home. We first analyzed a model set of 38 patients all of whom had at least two polysomnographic studies (the diagnostic one and a subsequent one to determine CPAPmin for home use), anthropometric measurements (including body mass index, neck circumference, and waist circumference), pulmonary function measurements (lung volumes, airways resistance, and flow-volume curves), pharyngeal and glottic cross-sectional areas at functional residual capacity and residual volume, and nasal airflow resistances. We compared patients requiring CPAP > 10 cm H2O with those who required CPAP < 5 cm H2O. The high CPAP group was characterized by a greater degree of obesity, more severe sleep apnea, and more collapsible pharynx. Multiple linear regression analysis using principal components and Mallows C(P) statistics revealed that the optimal set of predictors for CPAPmin consisted of only three variables: apnea/hypopnea index, body mass index, and neck circumference. This model accounted for 76% of the variability in CPAP. Prediction equation for CPAPmin based on this model was validated in a separate confirmation set of 129 patients and was found to agree closely with CPAPmin determined in the sleep laboratory (8.1 ± 3.0 cm H2O vs. 8.0 ± 2.1 cm H2O for the predicted and measured values, respectively). We conclude that (1) variability in pressures required to abolish sleep apnea are related primarily to obesity and severity of OSA, and (2) it is possible to predict the initial CPAP with sufficient accuracy to simplify the empiric determination of best CPAP in the sleep laboratory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Upper Airway Collapsibility in Snorers and in Patients with Obstructive Hypopnea and Apnea
Gleadhill, I. C., Schwartz, A. R., Schubert, N., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.6.1300 · Cited by 453
Disturbed sleep and prolonged apnea during nasal obstruction in normal men.
(1981) · PubMed · doi:10.1164/arrd.1981.124.2.158 · Cited by 247
The effect of nasal packing on sleep-disordered breathing and nocturnal oxygen desaturation
Taasan, V., Wynne, J. W., Cassisi, N., & Block, A. J. (1981) · The Laryngoscope · doi:10.1288/00005537-198107000-00015 · Cited by 120
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Evaluation of Positive Airway Pressure Treatment for Sleep Related Breathing Disorders in Adults
Gay, P., Weaver, T., Loube, D., & Iber, C. (2006) · Sleep · doi:10.1093/sleep/29.3.381 · Cited by 614
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Masa, J. F., Jiménez, A., Durán, J., Capote, F., Monasterio, C., Mayos, M., Terán, J., Hernández, L., Barbé, F., Maimó, A., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200312-1787oc · Cited by 328
Hedner, J., Darpo, B., Ejnell, H., Carlson, J., & Caidahl, K. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08020222 · Cited by 302
Use of nasal continuous positive airway pressure as treatment of childhood obstructive sleep apnea
Marcus, C. L., Ward, S. L. D., Mallory, G. B., Rosen, C. L., Beckerman, R. C., Weese-Mayer, D. E., Brouillette, R. T., Trang, H. T., & Brooks, L. J. (1995) · The Journal of Pediatrics · doi:10.1016/s0022-3476(95)70262-8 · Cited by 293
Metadata
- Authors
- Miljeteig, H., & Hoffstein, V.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-06
- Volume
- 147
- Issue
- 6_pt_1
- Pages
- 1526-1530
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2128888236
- Cited by
- 152
- References
- 4
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determinants of Continuous Positive Airway Pressure Level for Treatment of Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/ajrccm/147.6_pt_1.1526
- The paper
- Miljeteig, H., & Hoffstein, V. (1993). Determinants of Continuous Positive Airway Pressure Level for Treatment of Obstructive Sleep Apnea. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/147.6_pt_1.1526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.