Effect of Panting Frequency on the Plethysmographic Determination of Thoracic Gas Volume in Chronic Obstructive Pulmonary Disease 1– 3
The DOI matches its Crossref record.
Abstract
We studied the dependence of the Plethysmographic measurement of thoracic gas volume on the frequency of panting during occlusion in 3 normal subjects and in 10 patients with chronic obstructive pulmonary disease (COPD). Total lung capacity was derived using changes in both mouth (ΔPm) and esophageal (ΔPes) pressure to reflect changes in alveolar pressure (TLCm and TLCes, respectively). In the normal subjects, both TLCm and TLCes decreased slightly with increasing frequency of panting; the difference between TLCm and TLCes (TLCm—TLCes) was small and did not vary with frequency. In the patients, TLCes also decreased slightly, but, in contrast to the normal subjects, TLCm increased with increasing frequency. At low frequencies (less than 1 Hz), TLCm—TLCes averaged 0.14 ± 0.09 1 (mean ± SE) and was not significantly different from 0. However, TLCm — TLCes increased with frequency, averaging 1.49 ± 0.40 L at frequencies between 2.5 and 3 Hz. At all frequencies tested, cheek support reduced but did not abolish the error between TLCm and TLCes. At low frequencies, both ΔPm and ΔPes were in phase with changes in volume. However, at higher frequencies, changes in volume led changes in Pm, the phase angle between them increasing to almost 20° in one patient, whereas changes in Pes remained much more closely in phase with volume. Our results suggest that in patients with COPD, the Plethysmographic determination of absolute lung volume is valid only when the frequency of panting is low (less than 1 Hz); at higher panting frequencies, transmission of alveolar pressure to the mouth may be incomplete and result in artifactual increases in TLC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Standardisation of the measurement of lung volumes
Wanger, J., Clausen, J. L., Coates, A., Pedersen, O. F., Brusasco, V., Burgos, F., Casaburi, R., Crapo, R., Enright, P., van der Grinten, C. P. M., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035005 · Cited by 2,768
Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD
O'Donnell, D. E., Flüge, T., Gerken, F., Hamilton, A., Webb, K., Aguilaniu, B., Make, B., & Magnussen, H. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00116004 · Cited by 859
O'Donnell, D. E., Voduc, N., Fitzpatrick, M., & Webb, K. A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00072703 · Cited by 365
Metadata
- Authors
- Shore, S. A., Huk, O., Mannix, S., & Martin, J. G.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1983-07
- Volume
- 128
- Issue
- 1
- Pages
- 54-59
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1753921012
- Cited by
- 111
- References
- 0
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Panting Frequency on the Plethysmographic Determination of Thoracic Gas Volume in Chronic Obstructive Pulmonary Disease 1– 3. https://app.cochat.ai/papers/10.1164/arrd.1983.128.1.54
- The paper
- Shore, S. A., Huk, O., Mannix, S., & Martin, J. G. (1983). Effect of Panting Frequency on the Plethysmographic Determination of Thoracic Gas Volume in Chronic Obstructive Pulmonary Disease 1– 3. American Review of Respiratory Disease. https://doi.org/10.1164/arrd.1983.128.1.54
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.