Cited by 859Chronic Obstructive Pulmonary Disease (COPD) ResearchAsthma and respiratory diseasesInhalation and Respiratory Drug Delivery

Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD

O'Donnell, D.E., Flüge, T., Gerken, F., Hamilton, A., Webb, K., Aguilaniu, B., Make, B., Magnussen, H.·2004·European Respiratory Journal

Abstract

The aim of this study was to test the hypothesis that use of tiotropium, a new long-acting anticholinergic bronchodilator, would be associated with sustained reduction in lung hyperinflation and, thereby, would improve exertional dyspnoea and exercise performance in patients with chronic obstructive pulmonary disease. A randomised, double-blind, placebo-controlled, parallel-group study was conducted in 187 patients (forced expiratory volume in one second 44 +/- 13% pred): 96 patients received 18 microg tiotropium and 91 patients received placebo once daily for 42 days. Spirometry, plethysmographic lung volumes, cycle exercise endurance and exertional dyspnoea intensity at 75% of each patient's maximal work capacity were compared. On day 42, the use of tiotropium was associated with the following effects at pre-dose and post-dose measurements as compared to placebo: vital capacity and inspiratory capacity (IC) increased, with inverse decreases in residual volume and functional residual capacity. Tiotropium increased post-dose exercise endurance time by 105 +/- 40 s (21%) as compared to placebo on day 42. At a standardised time near end-exercise (isotime), IC, tidal volume and minute ventilation all increased, whilst dyspnoea decreased by 0.9 +/- 0.3 Borg scale units. In conclusion, the use of tiotropium was associated with sustained reductions of lung hyperinflation at rest and during exercise. Resultant increases in inspiratory capacity permitted greater expansion of tidal volume and contributed to improvements in both exertional dyspnoea and exercise endurance.

Integrity signals

Registry

Crossref · 10.1183/09031936.04.00116004

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • At peak exercise, notwithstanding the severity of the disease, patients with COPD show a consistent fall of approximately 20% of their resting IC at peak exercise.

    “At peak exercise, notwithstanding the severity of the disease, patients seem to show a consistent fall of approximately 20% of their resting IC at peak exercise.22–24,45–48”
  • Interventions that deflate the lungs and delay the onset of critical VT constraints consistently reduce dyspnea intensity in patients with COPD during exercise.

    “Moreover, interventions that deflate the lungs (ie, reduce EILV and EELV) and delay the onset of critical VT constraints consistently reduce dyspnea intensity in patients with COPD during exercise.45,46,55,56”
  • Pharmacological interventions that reduce operating lung volumes and delay the onset of ventilatory limitation consistently reduce the intensity of dyspnea during exercise in patients with COPD.

    “Pharmacological interventions that reduce operating lung volumes and delay the onset of ventilatory limitation consistently reduce the intensity of dyspnea during exercise in patients with COPD.46,55,56”
  • More than 80% of patients with moderate-to-severe COPD showed significant increases in EELV during exercise.

    “More than 80% of patients with moderate-to-severe COPD showed significant increases in EELV during exercise.11,13,46,150”
  • The improvement in airflow associated with effective bronchodilators will improve dyspnea and exercise tolerance.

    “The improvement in airflow associated with effective bronchodilators will improve dyspnea and exercise tolerance.94”

    From Anxiety and Depression in COPD (2008) · cites this paper as [94]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
O'Donnell, D. E., Flüge, T., Gerken, F., Hamilton, A., Webb, K., Aguilaniu, B., Make, B., & Magnussen, H.
Affiliations
  • Boehringer Ingelheim (Germany) (DE)
  • Queen's University (CA)
  • National Jewish Health (US)
Venue
European Respiratory Journal
Published
2004-06
Volume
23
Issue
6
Pages
832-840
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2121914298
Cited by
859
References
38
Citations by year
2026: 8 · 2025: 5 · 2024: 14 · 2023: 15 · 2022: 10 · 2021: 17 · 2020: 29 · 2019: 17 · 2018: 30 · 2017: 35 · 2016: 36 · 2015: 34 · 2014: 43 · 2013: 50 · 2012: 55
FWCI
63.27
Type
journal article
Language
en
Open access
closed
Locations
  • European Respiratory Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
  • Health Sciences › Medicine › Physiology › Asthma and respiratory diseases
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
Keywords
tiotropium, chronic obstructive pulmonary disease, lung hyperinflation, exertional dyspnea, exercise endurance, inspiratory capacity, residual volume, tidal volume, vital capacity
MeSH terms
Tiotropium Bromide, Aged, Analysis of Variance, Double-Blind Method, Dyspnea, Exercise Test, Female, Humans, Lung Volume Measurements, Male, Middle Aged, Physical Endurance, Plethysmography, Scopolamine Derivatives, Spirometry, Exercise Tolerance, Cholinergic Antagonists, Pulmonary Disease, Chronic Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review