Reducing Ventilatory Response to Carbon Dioxide by Breathing Cold Air 1– 3
The DOI matches its Crossref record.
Abstract
Abstract To study the effect of cooling of nasal receptors on breathing we had 10 normal male volunteers rebreathe through their noses 8% CO2 in oxygen at “warm” (23 to 30° C) and at “cold” (−4 to 10° C) temperatures. In order to further examine the effect of nasal receptors on the control of breathing, 11 subjects had their nasal response to CO2 measured at the warm temperature before and after topical nasal anesthesia. To exclude an increase in nasal resistance as the cause of the reduced response to CO2, 10 subjects had their nasal resistance measured before and after nasal rebreathing of cold 8% CO2 in oxygen. To also exclude increased bronchial resistance, forced expiratory volume in one second (FEV1) was measured in 12 subjects before and after nasal breathing of cold oxygen for 3 min. The mean ventilatory response to CO2 was reduced from 3.0 ± 1.6 L/min/mmHg to 2.5 ± 1.1 L/min/mmHg (p < 0.05) by the cold air. Topical nasal anesthesia increased the response to CO2 at the warm temperature from 2.4 ± 0.7 to 2.7 ± 0.9 L/min/mmHg. The effect of nasal breathing of 8% CO2 in oxygen at the cold temperature was to reduce nasal inspiratory resistance at 1 L/s from 4.3 ± 3.0 cm H2O L/s to 2.6 ± 1.0 cm H2O L/s (p < 0.05). Expiratory resistance at 1 L/s fell from 3.7 ± 1.5 cm H2O L/s to 2.4 ± 0.7 cm H2O L/s (p < 0.02). The FEV1 was unchanged by nasal breathing of cold oxygen. We feel that the reduction in the response to CO2 during nasal breathing of cold air was due to inhibition of respiratory output by nasal receptors and not to changes in nasal or bronchial resistance. The receptors have a minor influence on the control of breathing at warm temperatures and at resting levels of ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cold Facial Stimulation Reduces Breathlessness Induced in Normal Subjects
Schwartzstein, R. M., Lahive, K., Pope, A., Weinberger, S. E., & Weiss, J. W. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.1.58 · Cited by 284
Pathophysiology of empty nose syndrome
Sozansky, J., & Houser, S. M. (2015) · The Laryngoscope · doi:10.1002/lary.24813 · Cited by 112
“Subsequent studies showed that the ventilatory response to carbon dioxide was inhibited by breathing cool air through the nose.(19) These results support that cool thermoreceptors in the nasal mucosa are connected specifically to the respiratory centers.”
BackgroundSchwartzstein, R. M., Manning, H. L., Weiss, J. W., & Weinberger, S. E. (1990) · Lung · doi:10.1007/bf02719692 · Cited by 80
The role of the temperature of the nasal lining in the sensation of nasal patency
WILLATT, D. J., & JONES, A. S. (1996) · Clinical Otolaryngology · doi:10.1111/j.1365-2273.1996.tb01102.x · Cited by 46
Metadata
- Authors
- Burgess, K. R., & Whitelaw, W. A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1984-05
- Volume
- 129
- Issue
- 5
- Pages
- 687-690
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2239671153
- Cited by
- 53
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reducing Ventilatory Response to Carbon Dioxide by Breathing Cold Air 1– 3. https://app.cochat.ai/papers/10.1164/arrd.1984.129.5.687
- The paper
- Burgess, K. R., & Whitelaw, W. A. (1984). Reducing Ventilatory Response to Carbon Dioxide by Breathing Cold Air 1– 3. American Review of Respiratory Disease. https://doi.org/10.1164/arrd.1984.129.5.687
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.