Chest wall motion in sleep apnea.
The DOI matches its OpenAlex record.
Abstract
Patterns of rib cage (RC) and abdomen (ABD) motion obtained from a respiratory inductive plethysmograph were studied during disordered breathing events - obstructive apnea, obstructive hypopnea, mixed apnea, and central apnea - in 54 patients with sleep apnea. The type of disordered breathing event was verified by esophageal pressure and bias-flow mask recordings. Obstructive apnea occurred to a variable extent in all patients and was characterized by stereotyped paradoxical motion of the RC or ABD or both in 49 patients (91%). There was no paradox in 2 patients with "feeble" inspiratory effort during obstructions and in 3 patients with normal inspiratory effort during obstructed breaths. The more obese patients displayed paradox of the ABD rather than of the RC. Paradox did not occur in central apnea or in the central component of mixed apnea. Obstructive hypopnea was characterized by paradox during part of the breath. We conclude that RC and ABD motion can adequately characterize apnea in most patients and thus avoid invasive monitoring techniques that can adversely affect sleep. However, if chest wall motion suggests that all apneas are central, a direct measurement of respiratory effort is necessary to exclude obstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Continuous Positive Airway Pressure for Central Sleep Apnea and Heart Failure
Bradley, T. D., Logan, A. G., Kimoff, R. J., Sériès, F., Morrison, D., Ferguson, K., Belenkie, I., Pfeifer, M., Fleetham, J., Hanly, P., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa051001 · Cited by 1,189
Arzt, M., Floras, J. S., Logan, A. G., Kimoff, R. J., Series, F., Morrison, D., Ferguson, K., Belenkie, I., Pfeifer, M., Fleetham, J., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.683482 · Cited by 669
Sleepiness and Sleep in Patients With Both Systolic Heart Failure and Obstructive Sleep Apnea
Arzt, M. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.16.1716 · Cited by 394
Espinoza, H., Antic, R., Thornton, A. T., & McEvoy, R. D. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.1.80 · Cited by 73
Dellweg, D., Kerl, J., Hoehn, E., Wenzel, M., & Koehler, D. (2013) · Sleep · doi:10.5665/sleep.2878 · Cited by 64
Hsu, Y.-S., Chen, T.-Y., Wu, D., Lin, C.-M., Juang, J.-N., & Liu, W.-T. (2020) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8462 · Cited by 40
“18 Staats et al 19 suggested that respiratory efforts against the occlusion cause distortion of the chest wall and result in paradoxical motion of the rib cage, which can adequately characterize apnea in most patients.”
Metadata
- Authors
- Staats, B. A., Bonekat, H. W., Harris, C., & Offord, K. P.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 1984-07-01
- Volume
- 130
- Issue
- 1
- Pages
- 59-63
- OpenAlex
- W68413633
- Cited by
- 101
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.