The DOI matches its OpenAlex record.
Physiologic growth and development of the lung during the first year of life.
Abstract
Pulmonary function tests were performed on a total of 125 healthy infants younger than 25 postconception (pc) months of age. Maximal expiratory flow at functional residual capacity (VmaxFRC) was measured from partial expiratory flow-volume curves, and functional residual capacity (FRC) was measured by the helium dilution technique. There was a highly significant (p less than 0.01) linear regression for both VmaxFRC and FRC with increasing body length. The highest size-corrected flows (VmaxFRC/FRC) were obtained in the healthy premature (2.7 FRC/s, n = 6) and full-term (2.5 FRC/s, n = 5) infants, and there was a relatively constant value between 13 and 25 pc months of age (1.2 FRC/s), which was similar to those reported in older children and adults. In an age-matched group of infants 10 to 16 pc months of age, females had both higher absolute flows (126 versus 102 ml/s, p less than 0.03) and size-corrected flows (1.4 versus 1.0 FRC/s, p less than 0.001) than did males. These physiologic data support the concepts that neonates have proportionately larger airways relative to their lung volume at FRC, infants have size-corrected flows similar to those in older children and adults, and female infants have proportionately larger airways relative to their lung size than do male infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gender differences in airway behaviour over the human life span
Becklake, M. R., & Kauffmann, F. (1999) · Thorax · doi:10.1136/thx.54.12.1119 · Cited by 698
Stocks, J., & Quanjer, P. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08030492 · Cited by 688
Tucson children's respiratory study: 1980 to present
Taussig, L. M., Wright, A. L., Holberg, C. J., Halonen, M., Morgan, W. J., & Martinez, F. D. (2003) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2003.162 · Cited by 656
Self-citationStern, D. A., Morgan, W. J., Wright, A. L., Guerra, S., & Martinez, F. D. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61379-8 · Cited by 615
Self-citationde MARCO, R., LOCATELLI, F., SUNYER, J., BURNEY, P., & the European Community Respiratory Health Survey Study Group (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9907008 · Cited by 373
Metadata
- Authors
- Tepper, R. S., Morgan, W. J., Cota, K. A., Wright, A., & Taussig, L. M.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 1986-09-01
- Volume
- 134
- Issue
- 3
- Pages
- 513-9
- OpenAlex
- W2171362682
- Cited by
- 196
- References
- 0
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiologic growth and development of the lung during the first year of life. https://app.cochat.ai/papers/10.1164/arrd.1986.134.3.513
- The paper
- Tepper, R. S., Morgan, W. J., Cota, K. A., Wright, A., & Taussig, L. M. (1986). Physiologic growth and development of the lung during the first year of life. PubMed. https://doi.org/10.1164/arrd.1986.134.3.513
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.