Ultrafine Particle Deposition and Clearance in the Healthy and Obstructed Lung
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Numerous epidemiologic studies have shown associations between exposure to particulate air pollution and acute increases in morbidity and mortality, particularly in persons with chronic obstructive pulmonary disease. The dosimetry of ultrafine particles in the human lung is poorly characterized. We studied the deposition and clearance of an ultrafine technetium-99m-labeled aerosol in 10 patients with chronic obstructive pulmonary disease and in 9 healthy subjects. Particle retention was followed for 2 hours after inhalation and again at 24 hours by gamma scintigraphy. Central-to-peripheral ratios indexed airway deposition. Particle accumulation in the liver was examined by quantifying activity below the right lung. The dose rate for an aerosol exposure of 10 micro g/m(3) was calculated. Patients had a significantly greater dose rate than healthy subjects (2.9 +/- 1.0 versus 1.9 +/- 0.4 micro g/h, p = 0.02). Central-to-peripheral ratios were slightly greater in patients than in healthy subjects (1.11 +/- 0.10 versus 1.01 +/- 0.11, p = 0.05). Clearance did not statistically differ between health and disease. On average, 24-hour retention was 85 +/- 8% (corrected for isotope dissolution). No accumulation in the liver's vicinity was observed. Data suggest that relative to healthy subjects, patients with moderate-to-severe airways obstruction receive an increased dose from ultrafine particle exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mixed-Effects Models in S and S-PLUS
(2001) · Technometrics · doi:10.1198/tech.2001.s574 · Cited by 9,278 · cited 1×
“Total inspired volume was computed as the product retention curves through 2 hours after inhalation were tested by a linear of average inspiratory flow, aerosol inhalation time, and fraction of mixed-effects model (30, 31 ).”
MethodAn association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018 · cited 1×
“with obstructive and cardiovascular lung diseases ( 1 ,2).”
BackgroundChronic Obstructive Pulmonary Disease
(2018) · Questions for the Final FFICM Structured Oral Examination · doi:10.1017/9781108233712.025 · Cited by 2,689
Particulate air pollution and acute health effects
Seaton, A., Godden, D., MacNee, W., & Donaldson, K. (1995) · The Lancet · doi:10.1016/s0140-6736(95)90173-6 · Cited by 2,138
Changes in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907
Passage of inhaled particles into the blood circulation in humans
Nemmar, A., Hoet, P. H. M., Vanquickenborne, B., Dinsdale, D., Thomeer, M., Hoylaerts, M. F., Vanbilloen, H., Mortelmans, L., & Nemery, B. (2002) · Circulation · doi:10.1161/hc0402.104118 · Cited by 1,719 · cited 8×
“for Technegas, the aerosol used by Nemmar et al. ( 20 ).”
BackgroundMethodResultInfluentialRespiratory effects are associated with the number of ultrafine particles.
Peters, A., Wichmann, H. E., Tuch, T., Heinrich, J., & Heyder, J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.4.9105082 · Cited by 1,260
Review of Epidemiological Evidence of Health Effects of Particulate Air Pollution
Pope, C. A., Dockery, D. W., & Schwartz, J. (1995) · Inhalation Toxicology · doi:10.3109/08958379509014267 · Cited by 833
Pulmonary Retention of Ultrafine and Fine Particles in Rats
Ferin, J., Oberdörster, G., & Penney, D. P. (1992) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb/6.5.535 · Cited by 722
Increased plasma viscosity during an air pollution episode: a link to mortality?
Peters, A., Döring, A., Wichmann, H.-E., & Koenig, W. (1997) · The Lancet · doi:10.1016/s0140-6736(97)01211-7 · Cited by 706 · cited 1×
“coagulability (6). Increased plasma viscosity has been found in association with elevated sulfur dioxide and particulate levels ( 7 ).”
BackgroundIntercomparison of experimental regional aerosol deposition data
STAHLHOFEN, W., RUDOLF, G., & JAMES, A. C. (1989) · Journal of Aerosol Medicine · doi:10.1089/jam.1989.2.285 · Cited by 423
MEASUREMENT OF TOTAL LUNG DEPOSITION OF INHALED ULTRAFINE PARTICLES IN HEALTHY MEN AND WOMEN
Peter A. Jaques, C. S. K. (2000) · Inhalation Toxicology · doi:10.1080/08958370050085156 · Cited by 287
Clinical usefulness of the single-breath pulmonary diffusing capacity test.
Burrows, B., Kasik, J. E., Niden, A. H., & Barclay, W. R. (1961) · PubMed · doi:10.1164/arrd.1961.84.6.789 · Cited by 276
ANDERSON, P. J., Wilson, J. D., & Hiller, F. C. (1990) · CHEST Journal · doi:10.1378/chest.97.5.1115 · Cited by 144
The uptake of mineral particles by pulmonary epithelial cells.
Churg, A. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.4.8887617 · Cited by 136
Regional Impairment of Mucociliary Clearance in Chronic Obstructive Pulmonary Disease
Smaldone, G. C., Foster, W. M., O’Riordan, T. G., Messina, M. S., Perry, R. J., & Langenback, E. G. (1993) · CHEST Journal · doi:10.1378/chest.103.5.1390 · Cited by 117
King, G. G., Eberl, S., SALOME, C. M., Young, I. H., & Woolcock, A. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9608027 · Cited by 114
Respiratory dose of inhaled ultrafine particles in healthy adults
Kim, C. S., & Jaques, P. A. (2000) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2000.0678 · Cited by 110
Interpretation of "24 Hour Lung Retention" in Studies of Mucociliary Clearance
SMALDONE, G. C., PERRY, R. J., BENNETT, W. D., MESSINA, M. S., ZWANG, J., & ILOWITE, J. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.11 · Cited by 105
Self-citationSmooth-Muscle Myosin Light-Chain Kinase Content Is Increased in Human Sensitized Airways
Ammit, A. J., Armour, C. L., & BLACK, J. L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.1.9901005 · Cited by 97
Pulmonary retention and clearance of particles
Ferin, J. (1994) · Toxicology Letters · doi:10.1016/0378-4274(94)90018-3 · Cited by 72
Brown, J. S., Zeman, K. L., & Bennett, W. D. (2001) · Journal of Aerosol Medicine · doi:10.1089/08942680152744659 · Cited by 71
Self-citationIlowite, J. S., Smaldone, G. C., Perry, R. J., Bennett, W. D., & Foster, W. M. (1989) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1989.9935893 · Cited by 62
Self-citation(1988) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/32.inhaled_particles_vi.41 · Cited by 60
ENHANCED DEPOSITION OF FINE PARTICLES IN COPD PATIENTS SPONTANEOUSLY BREATHING AT REST
William D. Bennett, K. L. Z. (1997) · Inhalation Toxicology · doi:10.1080/089583797198376 · Cited by 59
Quantitative deposition of ultrafine stable particles in the human respiratory tract
Wilson, F. J., Hiller, F. C., Wilson, J. D., & Bone, R. C. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.1.223 · Cited by 43
Production of 99mTc-labeled iron oxide aerosols for human lung deposition and clearance studies
Wales, K. A., Petrow, H. G., & Yeates, D. B. (1980) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/0020-708x(80)90005-8 · Cited by 33
Relationship between regional ventilation and aerosol deposition in tidal breathing.
Trajan, M., Logus, J. W., Enns, E. G., & Man, S. F. P. (1984) · PubMed · doi:10.1164/arrd.1984.130.1.64 · Cited by 33
Dosimetric Issues Relating to Particulate Toxicity
Miller, F. J., Anjilvel, S., Ménache, M. G., Asgharian, B., & Gerrity, T. R. (1995) · Inhalation Toxicology · doi:10.3109/08958379509014469 · Cited by 30
Effect of ventilation distribution on aerosol bolus dispersion and recovery
Brown, J. S., Gerrity, T. R., & Bennett, W. D. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.6.2112 · Cited by 23
Self-citationRespiratory Tract Deposition of Polydisperse Aerosols in Humans
Diu, C. K., & Yu, C. P. (1983) · American Industrial Hygiene Association Journal · doi:10.1080/15298668391404374 · Cited by 20
Cited by
Toxic potential of materials at the nanolevel
Nel, A., Xia, T., Mädler, L., & Li, N. (2006) · Science · doi:10.1126/science.1114397 · Cited by 9,324
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891
Nanomaterials and nanoparticles: Sources and toxicity
Buzea, C., Pacheco, I. I., & Robbie, K. (2007) · Biointerphases · doi:10.1116/1.2815690 · Cited by 3,789
Translocation of inhaled ultrafine particles to the brain
Oberdörster, G., Sharp, Z., Atudorei, V., Elder, A., Gelein, R., Kreyling, W., & Cox, C. (2004) · Inhalation Toxicology · doi:10.1080/08958370490439597 · Cited by 2,606
Geiser, M., Rothen-Rutishauser, B., Kapp, N., Schürch, S., Kreyling, W., Schulz, H., Semmler, M., Hof, V. I., Heyder, J., & Gehr, P. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8006 · Cited by 1,407
Metadata
- Authors
- Brown, J. S., Zeman, K. L., & Bennett, W. D.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-11-01
- Volume
- 166
- Issue
- 9
- Pages
- 1240-1247
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2125539459
- Cited by
- 449
- References
- 31
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.