Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Hemodynamic Instability in Sepsis: Bedside Assessment by Doppler Echocardiography

Vieillard-Baron, Antoine, Prin, Sebastien, Chergui, Karim, Dubourg, Olivier, Jardin, François·2003·American Journal of Respiratory and Critical Care Medicine

Abstract

Septic shock is associated with important hemodynamic alterations, including absolute or relative decrease in central blood volume (1), systolic alterations of left ventricular (LV) (2, 3) and right ventricular (RV) (4) function, and severe peripheral vasodilatation responsible in part for alterations in regional blood flow distribution and probably linked to outcome (5). Hemodynamic treatment of septic shock requires blood volume expansion, which has proved to enhance survival if not delayed (6), and vasoactive support with catecholamines, according to the hemodynamic status (7). For a long time, assessment of hemodynamic instability in sepsis was based on right heart catheterization at the bedside. Recently, the Task Force of the American College of Critical Care Medicine reiterated the usefulness of right heart catheterization in guiding hemodynamic support in patients requiring more than an initial blood volume expansion (7). Concerns about the data obtained by this technique, and their interpretation in a mechanically ventilated patient, are not new (8). Moreover, this technique has been criticized for its invasiveness and associated specific complications (9). However, large cooperative clinical trials have not demonstrated an increase in mortality carried by right heart catheterization (10, 11). We abandoned right heart catheterization in our unit in 1990 and have replaced it by routine echocardiography. Since then, all patients hospitalized with septic shock have been monitored using echocardiography as a noninvasive bedside procedure. In our daily practice, echocardiography is performed after physical examination in all hemodynamically unstable patients and repeated immediately after each major hemodynamic intervention. For this purpose, the frozen multiplane probe can be kept in the esophagus for the time needed to assess the results of a major hemodynamic intervention (10–20 minutes). This strategy is original, few French teams use it, and no trial has demonstrated the usefulness of echocardiography in severe sepsis. But the quality of the data obtained and the growing demand for training from intensivists have convinced us that this procedure will be widely used in the future. Data from echocardiographic evaluation of a series of 183 patients have been published, emphasizing that a large spectrum of changes in ventricular systolic function can be observed in

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200306-816cc

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 265

Metadata

Authors
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2003-12-01
Volume
168
Issue
11
Pages
1270-1276
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2107415155
Cited by
265
References
2
FWCI
7.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamic Instability in Sepsis: Bedside Assessment by Doppler Echocardiography. https://app.cochat.ai/papers/10.1164/rccm.200306-816cc
The paper
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F. (2003). Hemodynamic Instability in Sepsis: Bedside Assessment by Doppler Echocardiography. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200306-816cc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.