Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Post-Bronchodilator Spirometry Reference Values in Adults and Implications for Disease Management

Johannessen, Ane, Lehmann, Sverre, Omenaas, Ernst R., Eide, Geir Egil, Bakke, Per S., Gulsvik, Amund · 2006 · American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: International guidelines promote the use of post-bronchodilator spirometry values in the definition and severity classification of chronic obstructive pulmonary disease. However, post-bronchodilator reference values have not yet been developed. OBJECTIVES: To derive reference values for post-bronchodilator forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and FEV1/FVC, and to compare these reference values with locally derived and existing pre-bronchodilator reference values. METHODS: Based on a random sample of a general adult population, 2,235 subjects (70% of invited subjects) performed spirometry with reversibility testing. A reference population of healthy never-smokers constituted 23% of the study population (n=515). Reference values for median and lower-limit-of-normal pre- and post-bronchodilator lung function and bronchodilator response were modeled using quantile regression analyses. MAIN RESULTS: The reference population had equal proportions of men and women in the age range 26-82 yr. Both FEV1 and FVC decreased with age and increased with height. FEV1/FVC decreased with age, although this trend was not statistically significant for men after bronchodilatation. Linear models gave the best overall fit. Lower-limit-of-normal post-bronchodilator FEV1/FVC exceeded 0.7 for both sexes. Post-bronchodilator prediction equations gave higher predicted FEV1 and FEV1/FVC than both locally derived and existing pre-bronchodilator equations. The bronchodilator response decreased with age. CONCLUSIONS: The present study is the first to develop reference values for post-bronchodilator lung function. Post-bronchodilator prediction equations can facilitate better management of patients with chronic obstructive pulmonary disease by avoiding falsely high FEV1% predicted with a subsequent underestimation of disease severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200601-023oc

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 177

Metadata

Authors
Johannessen, A., Lehmann, S., Omenaas, E. R., Eide, G. E., Bakke, P. S., & Gulsvik, A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2006-06-15
Volume
173
Issue
12
Pages
1316-1325
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2112278267
Cited by
177
References
6
FWCI
10.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Post-Bronchodilator Spirometry Reference Values in Adults and Implications for Disease Management. https://app.cochat.ai/papers/10.1164/rccm.200601-023oc
The paper
Johannessen, A., Lehmann, S., Omenaas, E. R., Eide, G. E., Bakke, P. S., & Gulsvik, A. (2006). Post-Bronchodilator Spirometry Reference Values in Adults and Implications for Disease Management. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200601-023oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.