Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Comparison of Biomarkers in Exhaled Breath Condensate and Bronchoalveolar Lavage

Jackson, Abigail S., Sandrini, Alessandra, Campbell, Charlotte, Chow, Sharron, Thomas, Paul S., Yates, Deborah H. · 2007 · American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Exhaled breath condensate (EBC) is increasingly studied as a noninvasive research method of sampling the lungs, measuring several biomarkers. The exact site of origin of substances measured in EBC is unknown, as is the clinical applicability of the technique. Special techniques might be needed to measure EBC biomarkers. OBJECTIVES: To assess biomarker concentrations in clinical disease and investigate the site of origin of EBC, we compared EBC and bronchoalveolar lavage (BAL) biomarkers in 49 patients undergoing bronchoscopy for clinical indications. MEASUREMENTS: We measured exhaled nitric oxide, 8-isoprostane, hydrogen peroxide, total nitrogen oxides, pH, total protein, and phospholipid (n = 33) and keratin (n = 15) to assess alveolar and mucinous compartments, respectively. EBC was collected over 10 min using a refrigerated condenser according to European Respiratory Society/American Thoracic Society recommendations, and BAL performed immediately thereafter. RESULTS: 8-Isoprostane, nitrogen oxides, and pH were significantly higher in EBC than in BAL (3.845 vs. 0.027 ng/ml, 28.4 vs. 3.8 microM, and 7.35 vs. 6.4, respectively; p < 0.001). Hydrogen peroxide showed no difference between EBC and BAL (17.5 vs. 20.6 microM, p = not significant), whereas protein was significantly higher in BAL (33.8 vs. 183.2 microg/ml, p < 0.001). Total phospholipid was also higher in EBC, but keratin showed no difference. No significant correlation was found between EBC and BAL for any of the biomarkers evaluated either before or after correction for dilution. CONCLUSIONS: In clinical disease, markers of inflammation and oxidative stress are easily measurable in EBC using standard laboratory techniques and EBC is readily obtained. However, EBC and BAL markers do not correlate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200601-107oc

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Jackson, A. S., Sandrini, A., Campbell, C., Chow, S., Thomas, P. S., & Yates, D. H.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2007-02-01
Volume
175
Issue
3
Pages
222-227
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2135460444
Cited by
159
References
3
FWCI
11.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Biomarkers in Exhaled Breath Condensate and Bronchoalveolar Lavage. https://app.cochat.ai/papers/10.1164/rccm.200601-107oc
The paper
Jackson, A. S., Sandrini, A., Campbell, C., Chow, S., Thomas, P. S., & Yates, D. H. (2007). Comparison of Biomarkers in Exhaled Breath Condensate and Bronchoalveolar Lavage. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200601-107oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.