Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea
The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.
Abstract
Rationale: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. Objectives: Our purpose was to compare the efficacy of both types of devices in patients with SDB. Methods: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. Measurements and Main Results: A total of 35 patients (29 males; age, 49 ± 9 yr; apnea–hypopnea index [AHI], 13 ± 11 events/h; body mass index, 28 ± 4 kg/m2) completed the protocol. AHI was only reduced with the custom-made device (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). Conclusions: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Comparison between device designs indicated that there are only minor differences in treatment effects between custom-made devices 78, 80, 83, 84, while a prefabricated device was less effective 85.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [85]
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364 · cited 1×
“To assess daytime sleepiness, the subjects completed an ESS at each evaluation (33).”
MethodRechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183 · cited 1×
“OSAHS, characterized by repetitive pharyngeal collapse during sleep, can be diagnosed in 4% of middle-aged men and 2% of women (1).”
BackgroundMcNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 7×
“Treatment with MADs may also be considered in subjects with OSAHS who do not tolerate or comply with CPAP or as a temporary alternative (7, 18, 19).”
BackgroundInfluentialEEG Arousals: Scoring Rules and Examples
(1992) · Sleep · doi:10.1093/sleep/15.2.173 · Cited by 1,637
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Cross-Over Trials in Clinical Research
(1994) · Technometrics · doi:10.1080/00401706.1994.10485798 · Cited by 763
Kushida, C. A., Morgenthaler, T. I., Littner, M. R., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2006) · Sleep · doi:10.1093/sleep/29.2.240 · Cited by 749
Research works printed but not linked: 8
- 1981, Lancet, 1, 862
- 2005, Cochrane Database Syst Rev, CD001004
- 2007, Sleep Breath, 11, 1
- 2006, Cochrane Database Syst Rev, CD004435
- 2004, Lancet, 360, 237
- 2005, Proc Am Thorac Soc, 2, A612
- 2002, Acta Otorhinolaryngol Belg, 56, 195
- 2002, Acta Otorhinolaryngol Belg, 56, 127
Cited by
Upper-Airway Stimulation for Obstructive Sleep Apnea
Strollo, P. J., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Froymovich, O., Hanson, R. D., Padhya, T. A., Steward, D. L., Gillespie, M. B., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1308659 · Cited by 1,299
Self-citationRamar, K., Dort, L. C., Katz, S. G., Lettieri, C. J., Harrod, C. G., Thomas, S. M., & Chervin, R. D. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4858 · Cited by 915
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“11,101 Although subjective adherence reports suggest short-term adherence is relatively good, 23,60,63,101 exceeding that of CPAP, the discrepancy between subjective and objective CPAP usage 4 suggests that better adherence to OA m cannot be confirmed in the absence of objective moni - toring.”
Self-citationNon-CPAP therapies in obstructive sleep apnoea
Randerath, W. J., Verbraecken, J., Andreas, S., Bettega, G., Boudewyns, A., Hamans, E., Jalbert, F., Paoli, J. R., Sanner, B., Smith, I., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00099710 · Cited by 388
Self-citationObstructive sleep apnoea syndrome and its management
Spicuzza, L., Caruso, D., & Di Maria, G. (2015) · Therapeutic Advances in Chronic Disease · doi:10.1177/2040622315590318 · Cited by 328
“Better outcomes and a better compliance have been obtained with custommade devices [Vanderveken et al. 2008].”
BackgroundVanderveken, O. M., Maurer, J. T., Hohenhorst, W., Hamans, E., Lin, H.-S., Vroegop, A. V., Anders, C., de Vries, N., & Van de Heyning, P. H. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2658 · Cited by 339
Self-citationObjective measurement of compliance during oral appliance therapy for sleep-disordered breathing
Vanderveken, O. M., Dieltjens, M., Wouters, K., De Backer, W. A., Van de Heyning, P. H., & Braem, M. J. (2013) · Thorax · doi:10.1136/thoraxjnl-2012-201900 · Cited by 297
Self-citationImplanted upper airway stimulation device for obstructive sleep apnea
Van de Heyning, P. H., Badr, M. S., Baskin, J. Z., Cramer Bornemann, M. A., De Backer, W. A., Dotan, Y., Hohenhorst, W., Knaack, L., Lin, H., Maurer, J. T., et al. (2012) · The Laryngoscope · doi:10.1002/lary.23301 · Cited by 261
“In summary, the present study confirms previous findings of the potentially therapeutic effect of respiratory-paced electrical stimulation of the hypoglossal nerve for moderate and severe OSA.”
BackgroundSelf-citationDrug‐induced sleep endoscopy in sleep‐disordered breathing: Report on 1,249 cases
Vroegop, A. V., Vanderveken, O. M., Boudewyns, A. N., Scholman, J., Saldien, V., Wouters, K., Braem, M. J., Van de Heyning, P. H., & Hamans, E. (2014) · The Laryngoscope · doi:10.1002/lary.24479 · Cited by 261
Self-citationNon-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy
Marklund, M., Verbraecken, J., & Randerath, W. (2012) · European Respiratory Journal · doi:10.1183/09031936.00144711 · Cited by 239
Self-citationSleep endoscopy with simulation bite for prediction of oral appliance treatment outcome
Vroegop, A. V. M. T., Vanderveken, O. M., Dieltjens, M., Wouters, K., Saldien, V., Braem, M. J., & Van de heyning, P. H. (2013) · Journal of Sleep Research · doi:10.1111/jsr.12008 · Cited by 172
“Mandibular advancement devices (MADs) are currently the most common class of oral appliances used to treat OSA and custommade MADs are to be preferred and recommended over prefabricated devices (Vanderveken et al., 2008).”
BackgroundSelf-citationEffect of upper-airway stimulation for obstructive sleep apnoea on airway dimensions
Safiruddin, F., Vanderveken, O. M., de Vries, N., Maurer, J. T., Lee, K., Ni, Q., & Strohl, K. P. (2015) · European Respiratory Journal · doi:10.1183/09031936.00059414 · Cited by 170
Self-citationDieltjens, M., Braem, M. J., Vroegop, A. V. M. T., Wouters, K., Verbraecken, J. A., De Backer, W. A., Van de Heyning, P. H., & Vanderveken, O. M. (2013) · Chest · doi:10.1378/chest.13-0613 · Cited by 171
Self-citationRamar, K., Dort, L. C., Katz, S. G., Lettieri, C. J., Harrod, C. G., Thomas, S. M., & Chervin, R. D. (2015) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.4868 · Cited by 169
Ahrens, A., McGrath, C., & Hägg, U. (2011) · European Journal of Orthodontics · doi:10.1093/ejo/cjq079 · Cited by 165
A promising concept of combination therapy for positional obstructive sleep apnea
Dieltjens, M., Vroegop, A. V., Verbruggen, A. E., Wouters, K., Willemen, M., De Backer, W. A., Verbraecken, J. A., Van de Heyning, P. H., Braem, M. J., de Vries, N., et al. (2015) · Sleep and Breathing · doi:10.1007/s11325-014-1068-8 · Cited by 146
“At the start of MAD therapy, patients were not judged suitable for MAD treatment if they suffered from any pre-existing active temporomandibular joint dysfunction, if their dental status or periodontal health precluded them from wearing an oral appliance, or if theywere fully edentulous [25, 26].”
BackgroundSelf-citationComparison of Adjustable and Fixed Oral Appliances for the Treatment of Obstructive Sleep Apnea
Lettieri, C. J., Paolino, N. D., Eliasson, A. H., Shah, A. A., & Holley, A. B. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1300 · Cited by 172
Dieltjens, M., Vanderveken, O. M., de Heyning, P. V., & Braem, M. J. A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.06.002 · Cited by 138
Self-citationSerra‐Torres, S., Bellot‐Arcís, C., Marco‐Algarra, J., & Almerich‐Silla, J. M. (2015) · The Laryngoscope · doi:10.1002/lary.25505 · Cited by 134
Effects of vertical opening on pharyngeal dimensions in patients with obstructive sleep apnoea
Vroegop, A. V. M. T., Vanderveken, O. M., de Heyning, P. V., & Braem, M. J. A. (2012) · Sleep Medicine · doi:10.1016/j.sleep.2011.08.005 · Cited by 135
“Mandibular advancement devices (MADs) are the most common type of oral appliances used for the treatment of OSA, and custom-made MADs are preferred [1,2].”
BackgroundSelf-citationOral appliance treatment of obstructive sleep apnea: an update
Chan, A. S., & Cistulli, P. A. (2009) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e3283319b12 · Cited by 103
Venema, J. A. M. U., Rosenmöller, B. R. A. M., de Vries, N., de Lange, J., Aarab, G., Lobbezoo, F., & Hoekema, A. (2021) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2021.101557 · Cited by 121
Quinnell, T. G., Bennett, M., Jordan, J., Clutterbuck-James, A. L., Davies, M. G., Smith, I. E., Oscroft, N., Pittman, M. A., Cameron, M., Chadwick, R., et al. (2014) · Thorax · doi:10.1136/thoraxjnl-2014-205464 · Cited by 97
de Beeck, S. O., Dieltjens, M., Verbruggen, A. E., Vroegop, A. V. M. T., Wouters, K., Hamans, E., Willemen, M., Verbraecken, J. A., Backer, W. A. D., de Heyning, P. V., et al. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7796 · Cited by 103
Self-citationOptimal positive airway pressure predicts oral appliance response to sleep apnoea
Tsuiki, S., Kobayashi, M., Namba, K., Oka, Y., Komada, Y., Kagimura, T., & Inoue, Y. (2009) · European Respiratory Journal · doi:10.1183/09031936.00121608 · Cited by 105
“Although the median (interquartile range) duration of nCPAP use was 9 (6-13) months in the present study, long-term effects of nCPAP use on the severity of OSA and PnCPAP are unknown.”
BackgroundInfluentialScherr, S. C., Dort, L. C., Almeida, F. R., Bennett, K. M., Blumenstock, N. T., Demko, B. G., Essick, G., Katz, S. G., McLornan, P. M., Phillips, K. S., et al. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3738 · Cited by 98
Heiser, C., Maurer, J. T., & Steffen, A. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1237-4 · Cited by 84
Cardiovascular Implications in the Treatment of Obstructive Sleep Apnea
Vanderveken, O. M., Boudewyns, A. N., Ni, Q., Kashyap, B., Verbraecken, J. A., Backer, W. D., & de Heyning, P. V. (2010) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-010-9238-y · Cited by 87
“Mandibular repositioning appliances (MRAs), which are worn intraorally at night to advance the mandible, are currently the most common class of oral appliances used to treat OSA [11, 66].”
BackgroundSelf-citationNon-CPAP therapy for obstructive sleep apnoea
Verbraecken, J. A., Dieltjens, M., de Beeck, S. O., Vroegop, A. V. M. T., Braem, M. J. A., Vanderveken, O. M., & Randerath, W. J. (2022) · Breathe · doi:10.1183/20734735.0164-2022 · Cited by 83
Self-citationNgiam, J., Balasubramaniam, R., Darendeliler, M., Cheng, A., Waters, K., & Sullivan, C. (2013) · Australian Dental Journal · doi:10.1111/adj.12111 · Cited by 77
Mandibular advancement splints for the treatment of sleep apnoea syndrome
Sutherland, K., & Cistulli, P. A. (2011) · Swiss Medical Weekly · doi:10.4414/smw.2011.13276 · Cited by 93
Vanderveken, O. M., Vroegop, A. V. M. T., de Heyning, P. V., & Braem, M. J. A. (2011) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2011.05.001 · Cited by 78
Self-citationUpdate on oral appliance therapy
Marklund, M., Braem, M. J. A., & Verbraecken, J. A. (2019) · European Respiratory Review · doi:10.1183/16000617.0083-2019 · Cited by 82
Self-citationOral Appliances in Obstructive Sleep Apnea
Dieltjens, M., & Vanderveken, O. M. (2019) · Healthcare · doi:10.3390/healthcare7040141 · Cited by 87
“A randomized controlled trial comparing the efficacy of a custom-made appliance with a thermoplastic device provided primary evidence that a custom-made MAD is more efficacious in reducing the OSA severity than a prefabricated MAD [19].”
BackgroundSelf-citationTsuiki, S., Ito, E., Isono, S., Ryan, C. F., Komada, Y., Matsuura, M., & Inoue, Y. (2013) · CHEST Journal · doi:10.1378/chest.12-2609 · Cited by 77
Vecchierini, M., Attali, V., Collet, J.-M., d’Ortho, M., Chater, P. E., Kerbrat, J.-B., Léger, D., Monaca, C. C., Monteyrol, P.-J., Morin, L., et al. (2015) · Sleep Medicine · doi:10.1016/j.sleep.2015.05.020 · Cited by 78
“Available data suggest that custom-made and adjustable devices are more effective than prefabricated, fixed, thermoplastic appliances [24,25].”
BackgroundAhrens, A., McGrath, C. P. J., & Hägg, U. (2010) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2010.01.030 · Cited by 76
Continuous Transcutaneous Submental Electrical Stimulation in Obstructive Sleep Apnea
Steier, J. S., Seymour, J. M., Rafferty, G. F., Jolley, C. J., Solomon, E., Luo, Y., Man, W. D., Polkey, M. I., & Moxham, J. (2011) · CHEST Journal · doi:10.1378/chest.10-2614 · Cited by 74
Vanderveken, O. M. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0671-9 · Cited by 71
“A custom-made, titratable MAD has been recommended [13–15].”
MethodSelf-citationMandibular Advancement Device Treatment Efficacy Is Associated with Polysomnographic Endotypes
de Beeck, S. O., Dieltjens, M., Azarbarzin, A., Willemen, M., Verbraecken, J. A., Braem, M. J. A., Wellman, A., Sands, S. A., & Vanderveken, O. M. (2021) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202003-220oc · Cited by 69
Self-citationDieltjens, M., Vanderveken, O. M., Hamans, E., Verbraecken, J. A., Wouters, K., Willemen, M., Backer, W. A. D., de Heyning, P. V., & Braem, M. J. A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0721-3 · Cited by 67
“The goal of MAD therapy is not only to lower the AHI, but also to relieve concomitant subjective symptoms in order to provide a long-term acceptable therapy [21, 31].”
BackgroundSelf-citationDieltjens, M., Verbruggen, A. E., Braem, M. J. A., Wouters, K., Verbraecken, J. A., Backer, W. A. D., Hamans, E., de Heyning, P. V., & Vanderveken, O. M. (2015) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2015.1756 · Cited by 75
Self-citationBasyuni, S., Barabas, M., & Quinnell, T. G. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.12.18 · Cited by 76
“This has previously been explored with a thermoplastic MAD (17).”
BackgroundKent, D. T., Rogers, R. R., & Soose, R. J. (2015) · Otolaryngology · doi:10.1177/0194599815586978 · Cited by 67
Principles of Oral Appliance Therapy for the Management of Snoring and Sleep Disordered Breathing
Almeida, F. R., & Lowe, A. A. (2009) · Oral and Maxillofacial Surgery Clinics of North America · doi:10.1016/j.coms.2009.07.002 · Cited by 67
Update on Oral Appliance Therapy for OSA
Marklund, M. (2017) · Current Sleep Medicine Reports · doi:10.1007/s40675-017-0080-5 · Cited by 65
Self-citationDenolf, P. L., Vanderveken, O. M., Marklund, M., & Braem, M. J. A. (2015) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.05.009 · Cited by 65
Self-citationOral Appliance Therapy for Obstructive Sleep Apnoea: State of the Art
Sutherland, K., & Cistulli, P. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8122121 · Cited by 65
“In one study, 63% of patients who did not receive any benefit using the non-customised device were treatment responders when using the customised device [53]; in another study, 44% of patients who did not respond to a non-customised device were treatment responders to customised ones [54].”
BackgroundMethodHolsbeke, C. S. V., Backer, J. D., Vos, W. G., Verdonck, P., Ransbeeck, P. V., Claessens, T. E., Braem, M. J. A., Vanderveken, O. M., & Backer, W. D. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.09.026 · Cited by 53
Self-citationBalasubramaniam, R., Klasser, G. D., Cistulli, P. A., & Lavigne, G. J. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3736 · Cited by 68
Backer, J. W. D., Vos, W. G., Verhulst, S. L., & Backer, W. D. (2008) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2008.07.009 · Cited by 54
Non–Positive Airway Pressure Modalities: Mandibular Advancement Devices/Positional Therapy
Chan, A. S. L., Lee, R. W. W., & Cistulli, P. A. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200707-104mg · Cited by 49
Johal, A., Haria, P., Manek, S., Joury, E., & Riha, R. L. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6440 · Cited by 56
“8,9 Excessive daytime sleepiness persisted in 33% and 66% of OSA patients, following MRD c and MRD r therapy, respectively.”
BackgroundResultInfluentialInteracting effects of genioglossus stimulation and mandibular advancement in sleep apnea
Oliven, R., Tov, N., Odeh, M., Gaitini, L., Steinfeld, U., Schwartz, A. R., & Oliven, A. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91501.2008 · Cited by 51
“However, MA produces only a partial clinical effect in OSA, even when custom-made devices are used (28).”
BackgroundMethodCompliance and Efficacy of Titratable Thermoplastic versus Custom Mandibular Advancement Devices
Friedman, M., Hamilton, C., Samuelson, C. G., Kelley, K. S., Pearson‐Chauhan, K., Taylor, D. R., Taylor, R., Maley, A. M., & Hirsch, M. A. (2012) · Otolaryngology · doi:10.1177/0194599812439683 · Cited by 54
“Oro-, velo-, and/or hypopharyngeal upper airway obstruction can all be potentially improved through mandibular repositioning.(3) CPAP is considered the gold standard for nonsurgical treatment but is often unpopular with patients, many of whom prefer MADs for their portability and less-invasive feel.”
BackgroundResultSide effects of boil and bite type oral appliance therapy in sleep apnea patients
Tsuda, H., Almeida, F. R., Masumi, S., & Lowe, A. A. (2009) · Sleep And Breathing · doi:10.1007/s11325-009-0304-0 · Cited by 49
“Although Vanderveken's study [11] showed significant differences in treatment effects between custom-made and boil and bite appliance, our results did not show a clear disadvantage in the boil and bite type, which is probably related to an overestimate of the boil and bite OA when using a subjective efficacy approach.”
BackgroundResultInfluentialFukuda, T., Tsuiki, S., Kobayashi, M., Nakayama, H., & Inoue, Y. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2013.12.007 · Cited by 48
“A >50% reduction in baseline AHI alone, posttreatment AHI <15 events per hour, and a reduction in AHI to <20 events per hour also have been used [2–28].”
BackgroundMethodCorso, E. D., Bastanza, G., Marca, G. D., Grippaudo, C., Rizzotto, G., Marchese, M. R., Fiorita, A., Sergi, B., Meucci, D., Nardo, W. D., et al. (2015) · Acta Otorhinolaryngologica Italica · doi:10.14639/0392-100x-959 · Cited by 50
Mayoral, P., Lagravère, M. O., Miguez-Contreras, M., & Garcia, M. (2019) · BMC Oral Health · doi:10.1186/s12903-019-0783-8 · Cited by 55
Mandibular advancement devices in obstructive sleep apnea: an updated review
Manetta, I. P., Ettlin, D. A., Mayoral, P., Rocha, I., & Cruz, M. G. M. E. (2022) · Sleep Science · doi:10.5935/1984-0063.20210032 · Cited by 57
“…are made in a fixed protrusive position remaining unchanged during treatment, while the protrusive position of the adjustable MAD allows progressive advances (e.g, titration process) aiming to increase the treatment efficacy and the patient’s comfort and quality of life (Figures 2 to 5) 26,41,43 .”
BackgroundUpdates in oral appliance therapy for snoring and obstructive sleep apnea
Chen, H., & Lowe, A. A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0712-4 · Cited by 65
“An evidence-based review [20] summarized side effects and complications from 38 published studies (over 1,700 patients evaluated) concluded that minor adverse effects were frequent whereas major adverse effects were uncommon while using OAs.”
BackgroundInfluentialDort, L. C., & Remmers, J. E. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1910 · Cited by 46
Impact of type D personality on adherence to oral appliance therapy for sleep-disordered breathing
Dieltjens, M., Vanderveken, O. M., den Bosch, D. V., Wouters, K., Denollet, J., Verbraecken, J. A., de Heyning, P. V., & Braem, M. J. A. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0788-x · Cited by 50
“Mandibular advancement devices (MADs), worn intraorally at night while protruding the mandible and reducing the collapsibility of the upper airway, are the most common oral appliances used to treat OSA [11, 12].”
BackgroundSelf-citationOral Appliances in the Management of Obstructive Sleep Apnea
Ng, J. H., & Yow, M. (2019) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2018.10.012 · Cited by 52
Oral Appliances for Snoring and Obstructive Sleep Apnea
Mickelson, S. A. (2020) · Otolaryngologic Clinics of North America · doi:10.1016/j.otc.2020.02.004 · Cited by 43
History of Dental Sleep Medicine
Rogers, R. R., Remmers, J. E., Lowe, A. A., Cistulli, P. A., Prinsell, J. R., & Pantino, D. A. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3744 · Cited by 41
Gagnadoux, F., Nguyên, X.-L., Vaillant, M. L., Priou, P., Meslier, N., Eberlein, A., Kün‐Darbois, J., Chaufton, C., Villiers, B., Levy, M., et al. (2017) · Respiratory Medicine · doi:10.1016/j.rmed.2017.08.004 · Cited by 48
Näpänkangas, R., Raunio, A., Sipilä, K., & Raustia, A. M. (2012) · Journal of Oral and Maxillofacial Research · doi:10.5037/jomr.2012.3405 · Cited by 41
“In addition, soft devices have been reported to be tolerated better than hard devices that were used in our study [19], although custom-made devices in general have been shown to be more effective (AHI, snoring) than prefabricated, thermoplastic devices [27].”
BackgroundEffectiveness and Outcome of Oral Appliance Therapy
Pliska, B. T., & Almeida, F. R. (2012) · Dental Clinics of North America · doi:10.1016/j.cden.2012.02.003 · Cited by 40
The role of oral appliance therapy in obstructive sleep apnoea
Johal, A., Hamoda, M. M., Almeida, F. R., Marklund, M., & Tallamraju, H. (2023) · European Respiratory Review · doi:10.1183/16000617.0257-2022 · Cited by 38
Self-citationComparison between mono-bloc and bi-bloc mandibular advancement devices for obstructive sleep apnea
Lee, W. H., Wee, J. H., Lee, C. H., Kim, M. S., Rhee, C., Yun, P., Yoon, I.-Y., & Kim, J. W. (2013) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-013-2417-0 · Cited by 42
Bartolucci, M. L., Bortolotti, F., Corazza, G., Parenti, S. I., Paganelli, C., & Bonetti, G. A. (2020) · Journal of Oral Rehabilitation · doi:10.1111/joor.13077 · Cited by 40
Sleep Medicine Education at Dental Schools in Australia and New Zealand
Balasubramaniam, R., Pullinger, A. G., & Simmons, M. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3728 · Cited by 37
Predictors of success for mandibular repositioning appliance in obstructive sleep apnea syndrome
Cunha, T. C. A., Guimarães, T. M., SCHULTZ, T. C. B., de ALMEIDA, F. R., Cunha, T. M., Júnior, P. C. S., & Bittencourt, L. (2017) · Brazilian Oral Research · doi:10.1590/1807-3107bor-2017.vol31.0037 · Cited by 42
Banhiran, W., Kittiphumwong, P., Assanasen, P., Chongkolwatana, C., & Metheetrairut, C. (2014) · The Laryngoscope · doi:10.1002/lary.24607 · Cited by 37
“The success rates of this study are thus comparable to those of several reports of custom-made OAs11,12,17 but higher than those of nonadjustable devices reported by Vanderveken et al.,14,15 Maurer et al.,13 and Friedman et al.10 In our opinion, these high success rates were possibly because 1) our devices could be fi…”
ResultInfluentialAlmeida, F. R., Mulgrew, A. T., Ayas, N., Tsuda, H., Lowe, A. A., Fox, N., Harrison, S., & Fleetham, J. A. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2576 · Cited by 30
“26 We are aware of one previous study which addressed the feasibility of using MAS as an adjunct treatment in patients previously established on CPAP.”
Johal, A., & Agha, B. (2018) · Journal of Sleep Research · doi:10.1111/jsr.12660 · Cited by 31
“Quinnell et al. (2014) applied a four-arm crossover RCT, whereas the other two trials used a two-arm crossover design (Johal et al., 2017; Vanderveken et al., 2008).”
BackgroundMethodResultInfluentialORal Appliance Network on Global Effectiveness (ORANGE): Start-Up and Design Description
Almeida, F. R., Vanderveken, O. M., Cistulli, P. A., Fleury, B., Gagnadoux, F., Hoekema, A., Huynh, N. T., Hwang, D., Kuna, S. T., Kushida, C. A., et al. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3730 · Cited by 28
Self-citationOral Appliances for Sleep-Disordered Breathing
Cistulli, P. A., Ferguson, K. A., & Lowe, A. A. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-6645-3.00109-2 · Cited by 28
How to treat patients that do not tolerate continuous positive airway pressure
Vanderveken, O. M., & Hoekema, A. (2010) · Breathe · doi:10.1183/20734735.020410 · Cited by 30
“Therefore, the conclusions should be limited to the devices tested and may not apply to other types of oral appliances presently available for the treatment of snoring and OSAHS [55, 56].”
BackgroundSelf-citationKastoer, C., Dieltjens, M., Oorts, E., Hamans, E., Braem, M. J. A., de Heyning, P. V., & Vanderveken, O. M. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6202 · Cited by 29
“30,31 A recent study, however, has emphasized the low predictive power of cephalometric parameters.”
Self-citationTallamraju, H., Newton, T., Fleming, P. S., & Johal, A. (2021) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9184 · Cited by 27
Management of Snoring and Obstructive Sleep Apnea with Mandibular Repositioning Appliances
Barewal, R. M., & Hagen, C. C. (2013) · Dental Clinics of North America · doi:10.1016/j.cden.2013.09.010 · Cited by 34
Geoghegan, F., Ahrens, A., McGrath, C. P. J., & Hägg, U. (2015) · The Angle Orthodontist · doi:10.2319/040314-245.1 · Cited by 26
Submental Ultrasonographic Parameters among Patients with Obstructive Sleep Apnea
Bilici, S., Acıoğlu, E., Yiğit, O., Çelebi, Ö. Ö., Yasak, A. G., & Yardımcı, A. H. (2017) · Otolaryngology · doi:10.1177/0194599816684109 · Cited by 30
Sheats, R. D., & Essick, G. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3742 · Cited by 24
Haviv, Y., Benoliel, R., Bachar, G. Y., & Michaeli, E. (2014) · PubMed · doi:10.3290/j.qi.a31337 · Cited by 26
Non-Pressure Therapies for Obstructive Sleep Apnea: Surgery and Oral Appliances
Woodson, B. T. (2010) · Respiratory Care · doi:10.4187/respcare.10551314 · Cited by 30
“Am J Respir Crit Care Med 2008;178(2):197-202.”
Levrini, L., Sacchi, F., Milano, F., Polimeni, A., Cozza, P., Bernkopf, E., Segù, M., Zucconi, M., Vicini, C., & Brunello, E. (2015) · Annali di stomatologia · doi:10.11138/ads/2015.6.3.081 · Cited by 27
“There are not sufficient data available to establish their ability to predict the efficacy o customized devices (23, 24).”
BackgroundVonk, P. E., Venema, J. A. M. U., Hoekema, A., Ravesloot, M. J. L., van de Velde–Muusers, J. A., & de Vries, N. (2020) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8378 · Cited by 24
Hedberg, P., Nohlert, E., & Tegelberg, Å. (2020) · Journal of Sleep Research · doi:10.1111/jsr.13253 · Cited by 23
Pilot Study of a New Mandibular Advancement Device
Segù, M., Campagnoli, G., Blasio, M. D., Santagostini, A., Pollis, M., & Levrini, L. (2022) · Dentistry Journal · doi:10.3390/dj10060099 · Cited by 22
“, comparing the efficacy of a customized versus a prefabricated device, found greater compliance and effectiveness with the custom-made appliance, while the thermoplastic MAD did not obtain a therapeutic effect due to lack of retention and lower comfort for the patients [4].”
BackgroundFactors associated with treatment adherence to mandibular advancement devices: a scoping review
van der Hoek, L. H., Rosenmöller, B. R. A. M., van de Rijt, L. J. M., de Vries, R., Aarab, G., & Lobbezoo, F. (2023) · Sleep And Breathing · doi:10.1007/s11325-023-02862-9 · Cited by 27
Mogell, K., Blumenstock, N. T., Mason, E., Rohatgi, R., Shah, S., & SCHWARTZ, D. B. (2019) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.7090 · Cited by 27
Gaver, H. V., de Beeck, S. O., Dieltjens, M., Backer, J. D., Verbraecken, J. A., Backer, W. A. D., de Heyning, P. V., Braem, M. J. A., & Vanderveken, O. M. (2021) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9694 · Cited by 25
“14,15 Improving the selection of potential successful candidates for MAD treatment is therefore desirable from both a therapeutic as well as a financial point of view.”
Self-citationBortolotti, F., Corazza, G., Bartolucci, M. L., Parenti, S. I., Paganelli, C., & Bonetti, G. A. (2021) · Journal of Oral Rehabilitation · doi:10.1111/joor.13290 · Cited by 23
Impact of an oral appliance on obstructive sleep apnea severity, quality of life, and biomarkers
Fernández‐Julián, E., Pérez‐Carbonell, T., Marco, R., Pellicer, V., Borja, E. R., & Marco, J. (2017) · The Laryngoscope · doi:10.1002/lary.26913 · Cited by 25
“The most common type of OA currently used for OSA treatment is the mandibular advancement device (MAD), and a custom-made device is preferred.(23,24) Studies on the efficacy of OAs for moderate-to-severe OSA are scarce, and in many instances did not analyze their effects on sleep structure and quality of life.”
MethodThe history and distribution of five exotic weeds in N. Carolina.
Patterson, D. T. (1976) · Castanea · Cited by 31
How to Treat Patients with Obstructive Sleep Apnea Syndrome during an Altitude Sojourn
Latshang, T. D., & Bloch, K. E. (2011) · High Altitude Medicine & Biology · doi:10.1089/ham.2011.1055 · Cited by 21
Hernández, C., Durán‐Cantolla, J., Lloberes, P., & González, M. (2009) · Archivos de Bronconeumología · doi:10.1016/s0300-2896(09)70264-9 · Cited by 27
Metadata
- Authors
- Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H.
- Affiliations
- University of Antwerp (BE)
- Antwerp University Hospital (BE)
- Umeå University (SE)
- Department of Otorhinolaryngology, Head and Neck Surgery
- Department of Dentistry, University Hospital Antwerp, Edegem, Belgium
- Department of Pulmonary Medicine, University Hospital Antwerp, Edegem, Belgium
- ORCID
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07
- Volume
- 178
- Issue
- 2
- Pages
- 197-202
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2110608739
- Cited by
- 289
- References
- 39
- Citations by year
- 2026: 2 · 2025: 10 · 2024: 9 · 2023: 13 · 2022: 22 · 2021: 14 · 2020: 13 · 2019: 22 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 25 · 2014: 37 · 2013: 17 · 2012: 20
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- mandibular advancement device, sleep-disordered breathing, mild sleep apnea, apnea-hypopnea index, snoring, medication adherence, patient preferences, mandibular advancement therapy
- MeSH terms
- Analysis of Variance, Female, Humans, Male, Middle Aged, Orthodontic Appliances, Removable, Snoring, Polysomnography, Cross-Over Studies, Mandibular Advancement, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.