Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Effect of upper-airway stimulation for obstructive sleep apnoea on airway dimensions

Safiruddin, Faiza, Vanderveken, Olivier M., de Vries, Nico, Maurer, Joachim T., Lee, Kent, Ni, Quan, Strohl, Kingman P. · 2015 · European Respiratory Journal

Abstract

Upper-airway stimulation (UAS) using a unilateral implantable neurostimulator for the hypoglossal nerve is an effective therapy for obstructive sleep apnoea patients with continuous positive airway pressure intolerance. This study evaluated stimulation effects on retropalatal and retrolingual dimensions during drug-induced sedation compared with wakefulness to assess mechanistic relationships in response to UAS. Patients with an implanted stimulator underwent nasal video endoscopy while awake and/or during drug-induced sedation in the supine position. The cross-sectional area, anterior–posterior and lateral dimensions of the retropalatal and retrolingual regions were measured during baseline and stimulation. 15 patients underwent endoscopy while awake and 12 underwent drug-induced sedation endoscopy. Increased levels of stimulation were associated with increased area of both the retropalatal and retrolingual regions. During wakefulness, a therapeutic level of stimulation increased the retropalatal area by 56.4% (p=0.002) and retrolingual area by 184.1% (p=0.006). During stimulation, the retropalatal area enlarged in the anterior–posterior dimension while retrolingual area enlarged in both anterior–posterior and lateral dimensions. During drug-induced sedation endoscopy, the same stimulation increased the retropalatal area by 180.0% (p=0.002) and retrolingual area by 130.1% (p=0.008). Therapy responders had larger retropalatal enlargement with stimulation than nonresponders. UAS increases both the retropalatal and retrolingual areas. This multilevel enlargement may explain reductions of the apnoea–hypopnoea index in selected patients receiving this therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00059414

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 170

Metadata

Authors
Safiruddin, F., Vanderveken, O. M., de Vries, N., Maurer, J. T., Lee, K., Ni, Q., & Strohl, K. P.
Venue
European Respiratory Journal
Published
2014-09-03
Volume
45
Issue
1
Pages
129-138
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2113725019
Cited by
170
References
8
FWCI
8.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of upper-airway stimulation for obstructive sleep apnoea on airway dimensions. https://app.cochat.ai/papers/10.1183/09031936.00059414
The paper
Safiruddin, F., Vanderveken, O. M., de Vries, N., Maurer, J. T., Lee, K., Ni, Q., & Strohl, K. P. (2015). Effect of upper-airway stimulation for obstructive sleep apnoea on airway dimensions. European Respiratory Journal. https://doi.org/10.1183/09031936.00059414

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.