Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment

Bouhemad, Belaïd, Brisson, Hélène, Le-Guen, Morgan, Arbelot, Charlotte, Lu, Qin, Rouby, Jean-Jacques·2011·American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: In the critically ill patients, lung ultrasound (LUS) is increasingly being used at the bedside for assessing alveolar-interstitial syndrome, lung consolidation, pneumonia, pneumothorax, and pleural effusion. It could be an easily repeatable noninvasive tool for assessing lung recruitment. OBJECTIVES: Our goal was to compare the pressure-volume (PV) curve method with LUS for assessing positive end-expiratory pressure (PEEP)-induced lung recruitment in patients with acute respiratory distress syndrome/acute lung injury (ARDS/ALI). METHODS: Thirty patients with ARDS and 10 patients with ALI were prospectively studied. PV curves and LUS were performed in PEEP 0 and PEEP 15 cm H₂O₂. PEEP-induced lung recruitment was measured using the PV curve method. MEASUREMENTS AND MAIN RESULTS: Four LUS entities were defined: consolidation; multiple, irregularly spaced B lines; multiple coalescent B lines; and normal aeration. For each of the 12 lung regions examined, PEEP-induced ultrasound changes were measured, and an ultrasound reaeration score was calculated. A highly significant correlation was found between PEEP-induced lung recruitment measured by PV curves and ultrasound reaeration score (Rho = 0.88; P < 0.0001). An ultrasound reaeration score of +8 or higher was associated with a PEEP-induced lung recruitment greater than 600 ml. An ultrasound lung reaeration score of +4 or less was associated with a PEEP-induced lung recruitment ranging from 75 to 450 ml. A statistically significant correlation was found between LUS reaeration score and PEEP-induced increase in Pa(O₂) (Rho = 0.63; P < 0.05). CONCLUSIONS: PEEP-induced lung recruitment can be adequately estimated with bedside LUS. Because LUS cannot assess PEEP-induced lung hyperinflation, it should not be the sole method for PEEP titration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201003-0369oc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 735

Metadata

Authors
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2011-02-01
Volume
183
Issue
3
Pages
341-347
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2118871737
Cited by
735
References
1
FWCI
12.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment. https://app.cochat.ai/papers/10.1164/rccm.201003-0369oc
The paper
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011). Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201003-0369oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.