CoChat

Loop Gain As a Means to Predict a Positive Airway Pressure Suppression of Cheyne-Stokes Respiration in Patients with Heart Failure

Sands, Scott A., Edwards, Bradley A., Kee, Kirk, Turton, Anthony, Skuza, Elizabeth M., Roebuck, Teanau, O'Driscoll, Denise M., Hamilton, Garun S., Naughton, Matthew T., Berger, Philip J. · 2011 · American Journal of Respiratory and Critical Care Medicine
Cited by 125

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

RATIONALE: Patients with heart failure (HF) and Cheyne-Stokes respiration or periodic breathing (PB) often demonstrate improved cardiac function when treatment with continuous positive airway pressure (CPAP) resolves PB. Unfortunately, CPAP is successful in only 50% of patients, and no known factor predicts responders to treatment. Because PB manifests from a hypersensitive ventilatory feedback loop (elevated loop gain [LG]), we hypothesized that PB persists on CPAP when LG far exceeds the critical threshold for stable ventilation (LG = 1). OBJECTIVES: To derive, validate, and test the clinical utility of a mathematically precise method that quantifies LG from the cyclic pattern of PB, where LG = 2π/(2πDR - sin2πDR) and DR (i.e., duty ratio) = (ventilatory duration)/(cycle duration) of PB. METHODS: After validation in a mathematical model of HF, we tested whether our estimate of LG changes with CPAP (n = 6) and inspired oxygen (n = 5) as predicted by theory in an animal model of PB. As a first test in patients with HF (n = 14), we examined whether LG predicts the first-night CPAP suppression of PB. MEASUREMENTS AND MAIN RESULTS: In lambs, as predicted by theory, LG fell as lung volume increased with CPAP (slope = 0.9 ± 0.1; R(2) = 0.82; P < 0.001) and as inspired-arterial PO(2) difference declined (slope = 1.05 ± 0.12; R(2) = 0.75; P < 0.001). In patients with HF, LG was markedly greater in 8 CPAP nonresponders versus 6 responders (1.29 ± 0.04 versus 1.10 ± 0.01; P < 0.001); LG predicted CPAP suppression of PB in 13/14 patients. CONCLUSIONS: Our novel LG estimate enables quantification of the severity of ventilatory instability underlying PB, making possible a priori selection of patients whose PB is immediately treatable with CPAP therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201103-0577oc

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 125

Metadata

Authors
Sands, S. A., Edwards, B. A., Kee, K., Turton, A., Skuza, E. M., Roebuck, T., O'Driscoll, D. M., Hamilton, G. S., Naughton, M. T., & Berger, P. J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2011-11-01
Volume
184
Issue
9
Pages
1067-1075
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2074985035
Cited by
125
References
3
FWCI
5.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Loop Gain As a Means to Predict a Positive Airway Pressure Suppression of Cheyne-Stokes Respiration in Patients with Heart Failure. https://app.cochat.ai/papers/10.1164/rccm.201103-0577oc
The paper
Sands, S. A., Edwards, B. A., Kee, K., Turton, A., Skuza, E. M., Roebuck, T., O'Driscoll, D. M., Hamilton, G. S., Naughton, M. T., & Berger, P. J. (2011). Loop Gain As a Means to Predict a Positive Airway Pressure Suppression of Cheyne-Stokes Respiration in Patients with Heart Failure. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201103-0577oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.