CoChat

Acute Upper Airway Responses to Hypoglossal Nerve Stimulation during Sleep in Obstructive Sleep Apnea

Open access
Schwartz, Alan R., Barnes, Maree, Hillman, David, Malhotra, Atul, Kezirian, Eric, Smith, Philip L., Hoegh, Thomas, Parrish, Daniel, Eastwood, Peter R. · 2012 · American Journal of Respiratory and Critical Care Medicine
Cited by 106

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

RATIONALE: Hypoglossal nerve stimulation (HGNS) recruits lingual muscles, reduces pharyngeal collapsibility, and treats sleep apnea. OBJECTIVES: We hypothesized that graded increases in HGNS relieve pharyngeal obstruction progressively during sleep. METHODS: Responses were examined in 30 patients with sleep apnea who were implanted with an HGNS system. Current (milliampere) was increased stepwise during non-REM sleep. Frequency and pulse width were fixed. At each current level, stimulation was applied on alternating breaths, and responses in maximal inspiratory airflow (V(I)max) and inspiratory airflow limitation (IFL) were assessed. Pharyngeal responses to HGNS were characterized by the current levels at which V(I)max first increased and peaked (flow capture and peak flow thresholds), and by the V(I)max increase from flow capture to peak (ΔV(I)max). MEASUREMENTS AND MAIN RESULTS: HGNS produced linear increases in V(I)max from unstimulated levels at flow capture to peak flow thresholds (215 ± 21 to 509 ± 37 ml/s; mean ± SE; P < 0.001) with increasing current from 1.05 ± 0.09 to 1.46 ± 0.11 mA. V(I)max increased in all patients and IFL was abolished in 57% of patients (non-IFL subgroup). In the non-IFL compared with IFL subgroup, the flow response slope was greater (1241 ± 199 vs. 674 ± 166 ml/s/mA; P < 0.05) and the stimulation amplitude at peak flow was lower (1.23 ± 0.10 vs. 1.80 ± 0.20 mA; P < 0.05) without differences in peak flow. CONCLUSIONS: HGNS produced marked dose-related increases in airflow without arousing patients from sleep. Increases in airflow were of sufficient magnitude to eliminate IFL in most patients and IFL and non-IFL subgroups achieved normal or near-normal levels of flow, suggesting potential HGNS efficacy across a broad range of sleep apnea severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201109-1614oc

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 106

Metadata

Authors
Schwartz, A. R., Barnes, M., Hillman, D., Malhotra, A., Kezirian, E., Smith, P. L., Hoegh, T., Parrish, D., & Eastwood, P. R.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2012-02-15
Volume
185
Issue
4
Pages
420-426
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2067472765
Cited by
106
References
9
FWCI
7.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute Upper Airway Responses to Hypoglossal Nerve Stimulation during Sleep in Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.201109-1614oc
The paper
Schwartz, A. R., Barnes, M., Hillman, D., Malhotra, A., Kezirian, E., Smith, P. L., Hoegh, T., Parrish, D., & Eastwood, P. R. (2012). Acute Upper Airway Responses to Hypoglossal Nerve Stimulation during Sleep in Obstructive Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201109-1614oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.