Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Fever Control Using External Cooling in Septic Shock: A Randomized Controlled Trial

Schortgen, Frédérique, Clabault, Karine, Katsahian, Sandrine, Devaquet, Jerome, Mercat, Alain, Deye, Nicolas, Dellamonica, Jean, Bouadma, Lila, Cook, Fabrice, Beji, Olfa, Brun-Buisson, Christian, Lemaire, François, Brochard, Laurent·2012·American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Fever control may improve vascular tone and decrease oxygen consumption, but fever may contribute to combat infection. OBJECTIVES: To determine whether fever control by external cooling diminishes vasopressor requirements in septic shock. METHODS: In a multicenter randomized controlled trial, febrile patients with septic shock requiring vasopressors, mechanical ventilation, and sedation were allocated to external cooling (n = 101) to achieve normothermia (36.5-37°C) for 48 hours or no external cooling (n = 99). Vasopressors were tapered to maintain the same blood pressure target in the two groups. The primary endpoint was the number of patients with a 50% decrease in baseline vasopressor dose after 48 hours. MEASUREMENTS AND MAIN RESULTS: Body temperature was significantly lower in the cooling group after 2 hours of treatment (36.8 ± 0.7 vs. 38.4 ± 1.1°C; P < 0.01). A 50% vasopressor dose decrease was significantly more common with external cooling from 12 hours of treatment (54 vs. 20%; absolute difference, 34%; 95% confidence interval [95% CI], -46 to -21; P < 0.001) but not at 48 hours (72 vs. 61%; absolute difference, 11%; 95% CI, -23 to 2). Shock reversal during the intensive care unit stay was significantly more common with cooling (86 vs. 73%; absolute difference, 13%; 95% CI, 2 to 25; P = 0.021). Day-14 mortality was significantly lower in the cooling group (19 vs. 34%; absolute difference, -16%; 95% CI, -28 to -4; P = 0.013). CONCLUSIONS: In this study, fever control using external cooling was safe and decreased vasopressor requirements and early mortality in septic shock.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201110-1820oc

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 259

Metadata

Authors
Schortgen, F., Clabault, K., Katsahian, S., Devaquet, J., Mercat, A., Deye, N., Dellamonica, J., Bouadma, L., Cook, F., Beji, O., Brun-Buisson, C., Lemaire, F., & Brochard, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2012-05-15
Volume
185
Issue
10
Pages
1088-1095
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1912388125
Cited by
259
References
38
FWCI
20.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fever Control Using External Cooling in Septic Shock: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1164/rccm.201110-1820oc
The paper
Schortgen, F., Clabault, K., Katsahian, S., Devaquet, J., Mercat, A., Deye, N., Dellamonica, J., Bouadma, L., Cook, F., Beji, O., Brun-Buisson, C., Lemaire, F., & Brochard, L. (2012). Fever Control Using External Cooling in Septic Shock: A Randomized Controlled Trial. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201110-1820oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.