CoChat

Electronic Implementation of a Novel Surveillance Paradigm for Ventilator-associated Events. Feasibility and Validation

Klein Klouwenberg, Peter M. C., van Mourik, Maaike S. M., Ong, David S. Y., Horn, Janneke, Schultz, Marcus J., Cremer, Olaf L., Bonten, Marc J. M. · 2014 · American Journal of Respiratory and Critical Care Medicine
Cited by 153

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

RATIONALE: Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced. OBJECTIVES: To determine the validity of surveillance using the new VAE algorithm. METHODS: Prospective cohort study in two Dutch academic medical centers (2011-2012). VAE surveillance was electronically implemented and included assessment of (infection-related) ventilator-associated conditions (VAC, IVAC) and VAP. Concordance with ongoing prospective VAP surveillance was assessed, along with clinical diagnoses underlying VAEs and associated mortality of all conditions. Consequences of minor differences in electronic VAE implementation were evaluated. MEASUREMENTS AND MAIN RESULTS: The study included 2,080 patients with 2,296 admissions. Incidences of VAC, IVAC, VAE-VAP, and VAP according to prospective surveillance were 10.0, 4.2, 3.2, and 8.0 per 1000 ventilation days, respectively. The VAE algorithm detected at most 32% of the patients with VAP identified by prospective surveillance. VAC signals were most often caused by volume overload and infections, but not necessarily VAP. Subdistribution hazards for mortality were 3.9 (95% confidence interval, 2.9-5.3) for VAC, 2.5 (1.5-4.1) for IVAC, 2.0 (1.1-3.6) for VAE-VAP, and 7.2 (5.1-10.3) for VAP identified by prospective surveillance. In sensitivity analyses, mortality estimates varied considerably after minor differences in electronic algorithm implementation. CONCLUSIONS: Concordance between the novel VAE algorithm and VAP was poor. Incidence and associated mortality of VAE were susceptible to small differences in electronic implementation. More studies are needed to characterize the clinical entities underlying VAE and to ensure comparability of rates from different institutions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201307-1376oc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 153

Metadata

Authors
Klein Klouwenberg, P. M. C., van Mourik, M. S. M., Ong, D. S. Y., Horn, J., Schultz, M. J., Cremer, O. L., & Bonten, M. J. M.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2014-04-15
Volume
189
Issue
8
Pages
947-955
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2136141163
Cited by
153
References
1
FWCI
21.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electronic Implementation of a Novel Surveillance Paradigm for Ventilator-associated Events. Feasibility and Validation. https://app.cochat.ai/papers/10.1164/rccm.201307-1376oc
The paper
Klein Klouwenberg, P. M. C., van Mourik, M. S. M., Ong, D. S. Y., Horn, J., Schultz, M. J., Cremer, O. L., & Bonten, M. J. M. (2014). Electronic Implementation of a Novel Surveillance Paradigm for Ventilator-associated Events. Feasibility and Validation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201307-1376oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.