The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The Preventability of Ventilator-associated Events. The CDC Prevention Epicenters Wake Up and Breathe Collaborative
Open accessAbstract
RATIONALE: The CDC introduced ventilator-associated event (VAE) definitions in January 2013. Little is known about VAE prevention. We hypothesized that daily, coordinated spontaneous awakening trials (SATs) and spontaneous breathing trials (SBTs) might prevent VAEs. OBJECTIVES: To assess the preventability of VAEs. METHODS: We nested a multicenter quality improvement collaborative within a prospective study of VAE surveillance among 20 intensive care units between November 2011 and May 2013. Twelve units joined the collaborative and implemented an opt-out protocol for nurses and respiratory therapists to perform paired daily SATs and SBTs. The remaining eight units conducted surveillance alone. We measured temporal trends in VAEs using generalized mixed effects regression models adjusted for patient-level unit, age, sex, reason for intubation, Sequential Organ Failure Assessment score, and comorbidity index. MEASUREMENTS AND MAIN RESULTS: We tracked 5,164 consecutive episodes of mechanical ventilation: 3,425 in collaborative units and 1,739 in surveillance-only units. Within collaborative units, significant increases in SATs, SBTs, and percentage of SBTs performed without sedation were mirrored by significant decreases in duration of mechanical ventilation and hospital length-of-stay. There was no change in VAE risk per ventilator day but significant decreases in VAE risk per episode of mechanical ventilation (odds ratio [OR], 0.63; 95% confidence interval [CI], 0.42-0.97) and infection-related ventilator-associated complications (OR, 0.35; 95% CI, 0.17-0.71) but not pneumonias (OR, 0.51; 95% CI, 0.19-1.3). Within surveillance-only units, there were no significant changes in SAT, SBT, or VAE rates. CONCLUSIONS: Enhanced performance of paired, daily SATs and SBTs is associated with lower VAE rates. Clinical trial registered with www.clinicaltrials.gov (NCT 01583413).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comorbidity measures for use with administrative data.
Elixhauser, A., Steiner, C., Harris, D. R., & Coffey, R. M. (1998) · Medical Care · doi:10.1097/00005650-199801000-00004 · Cited by 9,921
A Multicenter, Randomized, Controlled Clinical Trial of Transfusion Requirements in Critical Care
Hébert, P. C., Wells, G., Blajchman, M. A., Marshall, J., Martin, C., Pagliarello, G., Tweeddale, M., Schweitzer, I., & Yetisir, E. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902113400601 · Cited by 5,187
Schweickert, W. D., Pohlman, M. C., Pohlman, A. S., Nigos, C., Pawlik, A. J., Esbrook, C. L., Spears, L., Miller, M., Franczyk, M., Deprizio, D., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60658-9 · Cited by 3,339
van Walraven, C., Austin, P. C., Jennings, A., Quan, H., & Forster, A. J. (2009) · Medical Care · doi:10.1097/mlr.0b013e31819432e5 · Cited by 2,200
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
Cited by
Pun, B. T., Balas, M. C., Barnes-Daly, M. A., Thompson, J. L., Aldrich, J. M., Barr, J., Byrum, D., Carson, S. S., Devlin, J. W., Engel, H. J., et al. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003482 · Cited by 1,093
Self-citationThe ABCDEF Bundle: Science and Philosophy of How ICU Liberation Serves Patients and Families
Ely, E. W. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002175 · Cited by 514
Self-citationBarnes-Daly, M. A., Phillips, G., & Ely, E. W. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002149 · Cited by 425
Self-citationKlompas, M., Branson, R., Cawcutt, K., Crist, M., Eichenwald, E. C., Greene, L. R., Lee, G., Maragakis, L. L., Powell, K., Priebe, G. P., et al. (2022) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2022.88 · Cited by 402
Self-citationInterprofessional Care and Teamwork in the ICU
Donovan, A. L., Aldrich, J. M., Gross, A. K., Barchas, D. M., Thornton, K. C., Schell-Chaple, H. M., Gropper, M. A., & Lipshutz, A. K. M. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003067 · Cited by 313
Metadata
- Authors
- Klompas, M., Anderson, D., Trick, W., Babcock, H., Kerlin, M. P., Li, L., Sinkowitz-Cochran, R., Ely, E. W., Jernigan, J., Magill, S., Lyles, R., O’Neil, C., Kitch, B. T., Arrington, E., Balas, M. C., Kleinman, K., Bruce, C., Lankiewicz, J., Murphy, M. V., E. Cox, C., Lautenbach, E., Sexton, D., Fraser, V., Weinstein, R. A., & Platt, R.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-02-01
- Volume
- 191
- Issue
- 3
- Pages
- 292-301
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2126028344
- Cited by
- 192
- References
- 5
- FWCI
- 16.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Preventability of Ventilator-associated Events. The CDC Prevention Epicenters Wake Up and Breathe Collaborative. https://app.cochat.ai/papers/10.1164/rccm.201407-1394oc
- The paper
- Klompas, M., Anderson, D., Trick, W., Babcock, H., Kerlin, M. P., Li, L., Sinkowitz-Cochran, R., Ely, E. W., Jernigan, J., Magill, S., Lyles, R., O’Neil, C., Kitch, B. T., Arrington, E., Balas, M. C., Kleinman, K., Bruce, C., Lankiewicz, J., Murphy, M. V., . . . Platt, R. (2015). The Preventability of Ventilator-associated Events. The CDC Prevention Epicenters Wake Up and Breathe Collaborative. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201407-1394oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.