The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Physiological Comparison of High-Flow Nasal Cannula and Helmet Noninvasive Ventilation in Acute Hypoxemic Respiratory Failure
Abstract
Abstract Rationale High-flow nasal cannula (HFNC) and helmet noninvasive ventilation (NIV) are used for the management of acute hypoxemic respiratory failure. Objectives Physiological comparison of HFNC and helmet NIV in patients with hypoxemia. Methods Fifteen patients with hypoxemia with PaO2/FiO2 < 200 mm Hg received helmet NIV (positive end-expiratory pressure ≥ 10 cm H2O, pressure support = 10–15 cm H2O) and HFNC (50 L/min) in randomized crossover order. Arterial blood gases, dyspnea, and comfort were recorded. Inspiratory effort was estimated by esophageal pressure (Pes) swings. Pes-simplified pressure–time product and transpulmonary pressure swings were measured. Measurements and Main Results As compared with HFNC, helmet NIV increased PaO2/FiO2 (median [interquartile range]: 255 mm Hg [140–299] vs. 138 [101–172]; P = 0.001) and lowered inspiratory effort (7 cm H2O [4–11] vs. 15 [8–19]; P = 0.001) in all patients. Inspiratory effort reduction by NIV was linearly related to inspiratory effort during HFNC (r = 0.84; P < 0.001). Helmet NIV reduced respiratory rate (24 breaths/min [23–31] vs. 29 [26–32]; P = 0.027), Pes-simplified pressure–time product (93 cm H2O ⋅ s ⋅ min−1 [43–138] vs. 200 [168–335]; P = 0.001), and dyspnea (visual analog scale 3 [2–5] vs. 8 [6–9]; P = 0.002), without affecting PaCO2 (P = 0.80) and comfort (P = 0.50). In the overall cohort, transpulmonary pressure swings were not different between treatments (NIV = 18 cm H2O [14–21] vs. HFNC = 15 [8–19]; P = 0.11), but patients exhibiting lower inspiratory effort on HFNC experienced increases in transpulmonary pressure swings with helmet NIV. Higher transpulmonary pressure swings during NIV were associated with subsequent need for intubation. Conclusions As compared with HFNC in hypoxemic respiratory failure, helmet NIV improves oxygenation, reduces dyspnea, inspiratory effort, and simplified pressure–time product, with similar transpulmonary pressure swings, PaCO2, and comfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
High-Flow Oxygen through Nasal Cannula in Acute Hypoxemic Respiratory Failure
Frat, J.-P., Thille, A. W., Mercat, A., Girault, C., Ragot, S., Perbet, S., Prat, G., Boulain, T., Morawiec, E., Cottereau, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1503326 · Cited by 2,342
Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure
Rochwerg, B., Brochard, L., Elliott, M. W., Hess, D., Hill, N. S., Nava, S., Navalesi, P., Antonelli, M., Brozek, J., Conti, G., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.02426-2016 · Cited by 1,668
Self-citationAntonelli, M., Conti, G., Rocco, M., Bufi, M., De Blasi, R. A., Vivino, G., Gasparetto, A., & Meduri, G. U. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390703 · Cited by 1,014
Self-citationBellani, G., Laffey, J. G., Pham, T., Madotto, F., Fan, E., Brochard, L., Esteban, A., Gattinoni, L., Bumbasirevic, V., Piquilloud, L., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201606-1306oc · Cited by 667
Self-citationPhysiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Demoule, A., Chevret, S., Carlucci, A., Kouatchet, A., Jaber, S., Meziani, F., Schmidt, M., Schnell, D., Clergue, C., Aboab, J., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4087-4 · Cited by 194
Rochwerg, B., Granton, D., Wang, D. X., Einav, S., & Burns, K. E. A. (2019) · Intensive Care Medicine · doi:10.1007/s00134-019-05658-2 · Cited by 178
Cited by
Grieco, D. L., Menga, L. S., Cesarano, M., Rosà, T., Spadaro, S., Bitondo, M. M., Montomoli, J., Falò, G., Tonetti, T., Cutuli, S. L., et al. (2021) · JAMA · doi:10.1001/jama.2021.4682 · Cited by 473
Self-citationERS clinical practice guidelines: high-flow nasal cannula in acute respiratory failure
Oczkowski, S., Ergan, B., Bos, L., Chatwin, M., Ferrer, M., Gregoretti, C., Heunks, L., Frat, J.-P., Longhini, F., Nava, S., et al. (2022) · European Respiratory Journal · doi:10.1183/13993003.01574-2021 · Cited by 388
ERS/ESICM/ESCMID/ALAT guidelines for the management of severe community-acquired pneumonia
Martin-Loeches, I., Torres, A., Nagavci, B., Aliberti, S., Antonelli, M., Bassetti, M., Bos, L. D., Chalmers, J. D., Derde, L., de Waele, J., et al. (2023) · Intensive Care Medicine · doi:10.1007/s00134-023-07033-8 · Cited by 316
Self-citationGrieco, D. L., Maggiore, S. M., Roca, O., Spinelli, E., Patel, B. K., Thille, A. W., Barbas, C. S. V., de Acilu, M. G., Cutuli, S. L., Bongiovanni, F., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06459-2 · Cited by 286
Self-citationTonelli, R., Fantini, R., Tabbì, L., Castaniere, I., Pisani, L., Pellegrino, M. R., Della Casa, G., D’Amico, R., Girardis, M., Nava, S., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201912-2512oc · Cited by 274
“These findings are in line with data reported in a recent physiological study by Grieco and colleagues (21), in which DPes was unrelated to oxygenation impairment during helmet NIV and high-flow oxygen treatment.”
Result
Metadata
- Authors
- Grieco, D. L., Menga, L. S., Raggi, V., Bongiovanni, F., Anzellotti, G. M., Tanzarella, E. S., Bocci, M. G., Mercurio, G., Dell’Anna, A. M., Eleuteri, D., Bello, G., Maviglia, R., Conti, G., Maggiore, S. M., & Antonelli, M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-02-01
- Volume
- 201
- Issue
- 3
- Pages
- 303-312
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2983778965
- Cited by
- 192
- References
- 8
- FWCI
- 15.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiological Comparison of High-Flow Nasal Cannula and Helmet Noninvasive Ventilation in Acute Hypoxemic Respiratory Failure. https://app.cochat.ai/papers/10.1164/rccm.201904-0841oc
- The paper
- Grieco, D. L., Menga, L. S., Raggi, V., Bongiovanni, F., Anzellotti, G. M., Tanzarella, E. S., Bocci, M. G., Mercurio, G., Dell’Anna, A. M., Eleuteri, D., Bello, G., Maviglia, R., Conti, G., Maggiore, S. M., & Antonelli, M. (2020). Physiological Comparison of High-Flow Nasal Cannula and Helmet Noninvasive Ventilation in Acute Hypoxemic Respiratory Failure. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201904-0841oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.