Severe Astigmatic Blur Does Not Interfere with Spectacle Lens Compensation
The DOI matches its Crossref record.
Abstract
PURPOSE: Whether either natural emmetropization or compensation for imposed spectacle lenses requires the visual system to distinguish myopic from hyperopic blur is controversial. Some have argued that the visual system need only respond to the magnitude of the blur. This study was undertaken to test whether adding large amounts of astigmatic image blur would cause myopia and interfere with compensation for positive or negative spectacle lenses. METHODS: Chicks were fitted with mixed astigmatic (toric) lenses with +5 D on one meridian and -5 D on the orthogonal meridian (Jackson crossed cylinders), thus producing massive blur while having no spherical equivalent power. Chicks wore these lenses either alone or in combination with +6 D, +3 D, -3 D, or -6 D spherical lenses. To produce a similar degree of image degradation in a different way, other chicks were fitted with weak diffusers, with or without spherical lenses. RESULTS: Eyes fitted with astigmatic lenses alone became mildly hyperopic, whereas those fitted with weak diffusers became mildly myopic. Eyes wearing both the astigmatic and spherical lenses compensated as completely for the spherical lenses as did the eyes wearing spherical lenses alone-the compensation being caused by changes in both choroidal thickness and ocular length. Eyes wearing weak diffusers and spherical lenses also compensated but did so without a change in choroidal thickness. CONCLUSIONS: Severe astigmatic blur does not interfere with spectacle lens compensation. From this it can be inferred that the average amount of blur is not an important error signal for spectacle lens compensation and therefore probably not for emmetropization either. These results strengthen the case that the sign of defocus is used to direct eye growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Homeostasis of Eye Growth and the Question of Myopia
Wallman, J., & Winawer, J. (2004) · Neuron · doi:10.1016/j.neuron.2004.08.008 · Cited by 1,060
Self-citationThe complex interactions of retinal, optical and environmental factors in myopia aetiology
Flitcroft, D. I. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.06.004 · Cited by 903
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
Cone signals for spectacle-lens compensation: Differential responses to short and long wavelengths
Rucker, F. J., & Wallman, J. (2008) · Vision Research · doi:10.1016/j.visres.2008.06.003 · Cited by 99
“Furthermore, lightly frosted diffusers largely prevent positive lens-induced changes in choroidal thickness, but enhance the inhibition of ocular elongation ( McLean & Wallman, 2003; Park et al., 2003).”
BackgroundSelf-citationOptical quality of emmetropic and myopic eyes in the periphery measured with high-angular resolution
Jaeken, B., & Artal, P. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8993 · Cited by 75
Metadata
- Authors
- McLean, R. C., & Wallman, J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2003-02-01
- Volume
- 44
- Issue
- 2
- Pages
- 449
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1983274075
- Cited by
- 74
- References
- 0
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Severe Astigmatic Blur Does Not Interfere with Spectacle Lens Compensation. https://app.cochat.ai/papers/10.1167/iovs.01-0670
- The paper
- McLean, R. C., & Wallman, J. (2003). Severe Astigmatic Blur Does Not Interfere with Spectacle Lens Compensation. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.01-0670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.