CoChat

Potency of Myopic Defocus in Spectacle Lens Compensation

Zhu, Xiaoying, Winawer, Jonathan A., Wallman, Josh · 2003 · Investigative Opthalmology & Visual Science
Cited by 118

The DOI matches its Crossref record.

Abstract

PURPOSE: Previous studies have shown that chick eyes compensate for positive or negative lenses worn for brief periods if the chicks are in darkness the remainder of the time. This study was undertaken to determine whether chicks can compensate for brief periods of lens wear if given unrestricted vision the remainder of the time. Previous studies have also shown that chick eyes alternately wearing positive and negative lenses for brief periods compensate for the positive lenses. The current study sought to determine whether brief periods of positive lens wear can outweigh daylong wearing of negative lenses. METHODS: Chicks wore +6 D or +10 D lenses for between 8 and 60 min/d, in two to six periods and wore either no lenses or negative lenses for the remainder of the 12-hour daylight period. Refraction and ultrasound biometry were performed before and after the 3-day-long experiments. RESULTS: Wearing positive lenses for as little as 12 min/d (six periods of 2 minutes) with unrestricted vision the remainder of the time caused eyes to become hyperopic and reduced the rate of ocular elongation. These effects also occurred when the scene viewed was beyond the far point of the lens-wearing eye and thus was myopically blurred. Even when chicks wore negative lenses for the entire day except for 8 minutes of wearing positive lenses, the eyes compensated for the positive lenses, as though the negative lenses had not been worn. When chicks wore binocular negative lenses for the entire day except for 8 minutes of wearing a positive lens on one eye and a plano lens on the other, the eye wearing the positive lens became less myopic than the eye wearing the plano lens. CONCLUSIONS: Brief periods of myopic defocus imposed by positive lenses prevent myopia caused by daylong wearing of negative lenses. This implies that periods of myopic and hyperopic defocus do not add linearly. If children are like chicks and if the hyperopic defocus of long daily periods of reading predisposes a child to myopia, regular, brief interruptions of reading might have use as a prophylaxis against progression of myopia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.02-0606

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 118

Metadata

Authors
Zhu, X., Winawer, J. A., & Wallman, J.
Venue
Investigative Opthalmology & Visual Science
Published
2003-07-01
Volume
44
Issue
7
Pages
2818
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2079232964
Cited by
118
References
0
FWCI
4.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Potency of Myopic Defocus in Spectacle Lens Compensation. https://app.cochat.ai/papers/10.1167/iovs.02-0606
The paper
Zhu, X., Winawer, J. A., & Wallman, J. (2003). Potency of Myopic Defocus in Spectacle Lens Compensation. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.02-0606

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.