Feasibility of Drug Delivery to the Posterior Pole of the Rabbit Eye with an Episcleral Implant

Kato, Aki, Kimura, Hideya, Okabe, Komei, Okabe, Junko, Kunou, Noriyuki, Ogura, Yuichiro · 2004 · Investigative Opthalmology & Visual Science
Cited by 66

The DOI matches its Crossref record.

Abstract

PURPOSE: To evaluate the feasibility of a nonbiodegradable polymeric episcleral implant as a new controlled intraocular delivery system of betamethasone (BM) to the posterior pole of the eye. METHODS: The episcleral implant, which is composed of a drug-releasing component and a suture tag, released BM through an ethylene vinyl acetate membrane. The implants were placed on the sclera in 12 eyes of 12 Japanese white rabbits so that the drug-releasing surface could attach to the sclera at the posterior pole. BM concentrations in the aqueous humor, vitreous, and retina-choroid (posterior half and anterior half) were determined by high-performance liquid chromatography (HPLC) at weeks 1, 2, and 4 after implantation. In addition, the intraocular tissue distribution of the drug was evaluated by fluorescein microscopy after implantation of the implant loaded with 6-carboxy fluorescein diacetate (6-CFDA) as a drug marker. Retinal toxicity was evaluated by electroretinography and histologic examination. RESULTS: The implant showed zero-order release profiles both in vitro and in vivo for 4 weeks. BM concentrations in the retina-choroid after implantation were maintained above the concentrations effective for suppressing inflammatory reactions for at least 4 weeks. The BM concentration was greater in the posterior half of the retina-choroid than in the vitreous. It was confirmed that 6-CFDA penetrated through the sclera and dispersed into the retina-choroid. Fluorescence from 6-CFDA gradually decreased in intensity with increased distance from the implantation site. Electroretinography and histologic study showed no substantial toxic reactions. CONCLUSIONS: These findings suggest that the episcleral implant may be a useful drug carrier for intraocular delivery of BM, especially for the posterior part of the eye.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.02-1258

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 66

Metadata

Authors
Kato, A., Kimura, H., Okabe, K., Okabe, J., Kunou, N., & Ogura, Y.
Venue
Investigative Opthalmology & Visual Science
Published
2004-01-01
Volume
45
Issue
1
Pages
238
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2023936996
Cited by
66
References
0
FWCI
2.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of Drug Delivery to the Posterior Pole of the Rabbit Eye with an Episcleral Implant. https://app.cochat.ai/papers/10.1167/iovs.02-1258
The paper
Kato, A., Kimura, H., Okabe, K., Okabe, J., Kunou, N., & Ogura, Y. (2004). Feasibility of Drug Delivery to the Posterior Pole of the Rabbit Eye with an Episcleral Implant. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.02-1258

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.