Cited by 209Corneal surgery and disordersCorneal Surgery and TreatmentsCollagen: Extraction and Characterization

Collagen fibrils appear more closely packed in the prepupillary cornea: optical and biomechanical implications

Open access
Boote, Craig, Dennis, Sally, Newton, Richard H., Puri, Hina, Meek, Keith M.·2003·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: The size and organization of stromal collagen fibrils influence the biomechanical and optical properties of the cornea and hence its function. How fibrillar structure varies with position across the cornea has not been fully characterized. The present study was designed to quantify the collagen fibril spacing and diameter across the normal human cornea and to relate this to the properties of the tissue. METHODS: Small-angle x-ray diffraction was used to map in detail the variation in fibril spacing and fibril diameter along orthogonal medial-lateral and inferior-superior meridians of five normal human corneoscleral discs. RESULTS: Mean fibril diameters remained constant across all corneas up to the limbus, whereupon a sharp increase was observed. However, mean fibril spacing across the central 4 x 3 mm (prepupillary) cornea measured 5% to 7% lower than in the peripheral cornea. CONCLUSIONS: Collagen fibrils in the prepupillary cornea appear to be more closely packed than in the peripheral cornea. Anisotropy in fibril packing across the cornea has potential implications for the transparency and refractive index of the tissue. Biomechanically, it is possible that the higher packing density of stress-bearing collagen fibrils in the prepupillary cornea is necessary for maintaining corneal strength, and hence curvature, in a region of reduced tissue thickness. By inference, these results could have important implications for the development of corneal models for refractive surgery.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.03-0131

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The decrease in transmittance outside the central 4 mm pre-pupillary cornea is attributed to the increase in fibril radius that occurs in the periphery of the cornea.

    “Theoretical calculations of light transmission (Doutch et al., 2008) attributed this to the increase in fibril radius that occurs in the periphery of the cornea (Boote et al., 2003).”

    From Corneal structure and transparency (2015) · cites this paper as Boote et al., 2003

    The Results (Fig. 5 and Table 2, near p. 2944) say fibril diameter remained constant from the corneal center to the limbus, with no significant difference between the prepupillary and peripheral zones. The reported increase occurs across the limbus, not within the peripheral cornea, so this paper contradicts the attributed explanation. (LLM, conf=0.93)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 30

  1. Waring GO. Making sense of keratospeak II: proposed conven- tional terminology for corneal topography. Refract Corn Surg. 1989;5:362-367.
  2. Maurice DM. The structure and transparency of the corneal stroma. J Physiol. 1957;136:263-286.
  3. Hukins DWL, Aspden RM. Composition and properties of connec- tive tissues. Trends Biochem Sci. 1985;10:260 -264.
  4. Jeronimidis G, Vincent JFV. Composite materials. In: Hukins DWL ed. Connective Tissue Matrix. Macmillan; 1984:187-210.
  5. Farrell RA. Corneal transparency. In: Albert DM, Jacobiec SA, eds. Principles and Practice of Ophthalmology. Philadelphia: Saunders; 1994.
  6. Meek KM, Quantock AJ. The use of X-ray scattering techniques to determine corneal ultrastructure. Prog Retinal Eye Res. 2001;20: 95-137.
  7. Meek KM, Leonard DW. Ultrastructure of the corneal stroma: a comparative study. Biophys J. 1993;64:273-280.
  8. Freund DE, McCally RL, Farrell RA, Cristol SM, L'Hernault NL, Edelhauser HF. Ultrastructure in anterior and posterior stroma of IOVS, July 2003, Vol. 44, No. 7 Closer Fibril Packing in the Prepupillary Cornea 2947 perfused human and rabbit corneas: relation to transparency. In- vest Ophthalmol Vis Sci. 1995;36:1508 -1523.
  9. Kanai A, Kaufman HE. Electron microscopic studies of corneal stroma: ageing changes of collagen fibres. Ann Ophthalmol. 1973; 5:285-292.
  10. Craig AS, Parry DAD. Collagen fibrils of the vertebrate corneal stroma. J Ultra Mol Struct Res. 1981;74:232-239.
  11. Borcherding MS, Blacik LJ, Sittig RA, Bizzell JW, Breen M, Wein- stein HG. Proteoglycans and collagen fibre organisation in human corneoscleral tissue. Exp Eye Res. 1975;21:59 -70.
  12. Fullwood NJ, Meek KM. A synchrotron X-ray study of the changes occurring in the corneal stroma during processing for electron- microscopy. J Microsc. 1993;169:53-60.
  13. Craig AS, Robertson JG, Parry DAD. Preservation of corneal colla- gen fibril structure using low-temperature procedures for electron microscopy. J Ultra Mol Struct Res. 1986;96:172-175.
  14. Daxer A, Misof K, Grabner B, Ettl A, Fratzl P. Collagen fibrils in the human corneal stroma: structure and ageing. Invest Ophthalmol Vis Sci. 1998;39:644 -648.
  15. Oster G, Riley DP. Scattering from cylindrically symmetric systems. Acta Crystallogr. 1952;5:272-276.
  16. Worthington CR, Inouye H. X-ray diffraction study of the cornea. Int J Biol Macromol. 1985;7:2-8.
  17. Meek KM, Fullwood NJ, Cooke PH, et al. Synchrotron X-ray dif- fraction studies of the cornea, with implications for stromal hydra- tion. Biophys J. 1991;60:467-474.
  18. Hart RW, Farrell RA. Light scattering in the cornea. J Opt Soc Am. 1969;59:766 -774.
  19. Freund DE, McCally RL, Farrell RA. Direct summation of fields for light scattering by fibrils with applications to normal corneas. Appl Opt. 1986;25:2739 -2746.
  20. Martola EL, Baum JL. Central and peripheral corneal thickness. Arch Ophthalmol. 1968;79:28 -30.
  21. Edmund C. Determination of the corneal thickness pro- file by optical pachometry. Acta Ophthalmol. 1987;65:147- 152.
  22. Leonard DW, Meek KM. Estimation of the refractive indices of collagen fibrils and ground substance of the corneal stroma using data from X-ray diffraction. Biophys J. 1997;72:1382- 1387.
  23. Maurice DM. The cornea and sclera. In: Davson H, ed. The Eye. New York: Academic Press; 1969:489 -599.
  24. Muir H, Bullough P, Maroudas A. The distribution of collagen in human articular cartilage with some of its physiological implica- tions. J Bone Surg Ser B. 1970;52:554 -563.
  25. Fratzl P, Daxer A. Structural transformation of collagen fibrils in corneal stroma during drying: an X-ray scattering study. Biophys J. 1993;64:1210 -1214.
  26. Hanna KD, Jouve FE, Waring GO, Ciarlet PG. Computer simulation of arcuate keratotomy for astigmatism. Refract Corneal Surg. 1992;8:152-163.
  27. Moreira H, Campos M, Sawush MR, McDonnell JM, Sand B, Mc- Donald PJ. Holmium laser thermokeratoplasty. Ophthalmology. 1993;100:752-761.
  28. Newton RH, Meek KM. The integration of the corneal and limbal fibrils in the human eye. Biophys J. 1998;75:2508 -2512.
  29. Newton RH, Meek KM. Circumcorneal annulus of collagen fibrils in the human limbus. Invest Ophthalmol Vis Sci. 1998;39:1125-1134.
  30. Meek KM, Newton RH. Organisation of collagen fibrils in the corneal stroma in relation to mechanical properties and surgical practice. J Refract Surg. 1999;15:695-699.

Cited by

Sorted by citations

Authors
Boote, C., Dennis, S., Newton, R. H., Puri, H., & Meek, K. M.
Affiliations
Cardiff University (GB)
Venue
Investigative Opthalmology & Visual Science
Published
2003-07-01
Volume
44
Issue
7
Pages
2941
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2095516478
Cited by
209
References
0
Citations by year
2026: 5 · 2025: 7 · 2024: 8 · 2023: 6 · 2022: 9 · 2021: 9 · 2020: 7 · 2019: 11 · 2018: 11 · 2017: 10 · 2016: 7 · 2015: 7 · 2014: 16 · 2013: 6 · 2012: 7
FWCI
4.60
Type
journal article
Language
en
Open access
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (acceptedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
Funders
  • Wellcome Trust
  • Medical Research Council (G0001033)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
Keywords
corneal collagen fibrils, fibril diameter, corneal biomechanics, corneal transparency, refractive index, limbus, corneal curvature
MeSH terms
Biomechanical Phenomena, Collagen, Corneal Stroma, Humans, X-Ray Diffraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review