The DOI matches its Crossref record.
Relationship between Visual Field Sensitivity and Retinal Nerve Fiber Layer Thickness as Measured by Scanning Laser Polarimetry
Abstract
PURPOSE: To evaluate the strength and pattern of the relationship between visual field (VF) sensitivity and retinal nerve fiber layer (RNFL) thickness measurements by scanning laser polarimetry (SLP). METHODS: Fifty-four eyes of 54 normal subjects (age, 42 +/- 15 years; VF mean deviation [MD], -0.69 +/- 1.01 dB) and 51 eyes of 51 glaucoma patients (age, 66 +/- 14 years; VF MD, -6.92 +/- 5.43 dB) were imaged with an SLP using fixed corneal compensation (FCC) and variable corneal compensation (VCC). VF sensitivity was recorded in the dB and the 1/L scales. Linear and logarithmic relationships were sought globally and in six VF sectors. Relationships of VF and RNFL thickness with age were sought in normal subjects. RESULTS: Both VF sensitivity and RNFL thickness declined with age (as determined by the regression slope): -0.13% (P = 0.0005) and -0.64% (P = 0.0001) per year for dB and 1/L VF sensitivity, respectively, and -0.25% (P = 0.003) per year for VCC RNFL thickness. FCC RNFL thickness was not statistically significantly related to age. The relationship of VF sensitivity to VCC global (R(2) = 0.49) and sectoral (R(2) = 0.00-0.47) RNFL thickness was greater than for FCC global (R(2) = 0.12) and sectoral (R(2) = 0.00-0.21) RNFL thickness. Relationships were curvilinear with the dB scale, with logarithmic regression of dB VF sensitivity against RNFL thickness being significantly better than linear regression. Logarithmic regression of 1/L VF sensitivity against RNFL thickness was no better than linear regression for all sectors. There was no relationship between VF sensitivity and RNFL thickness in the temporal peripapillary RNFL sector. CONCLUSIONS: The strength of the structure/function relationships compare well with previous reports in the literature. The relationships were curvilinear with the dB scale and linear with the 1/L scale, and were much stronger with VCC than with FCC RNFL thickness measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retinal nerve fiber layer axonal loss and visual dysfunction in optic neuritis
Trip, S. A., Schlottmann, P. G., Jones, S. J., Altmann, D. R., Garway-Heath, D. F., Thompson, A. J., Plant, G. T., & Miller, D. H. (2005) · Annals of Neurology · doi:10.1002/ana.20575 · Cited by 509
Self-citationRetinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography
Leung, C. K.-S., Cheung, C. Y.-L., Weinreb, R. N., Qiu, Q., Liu, S., Li, H., Xu, G., Fan, N., Huang, L., Pang, C.-P., et al. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.013 · Cited by 486
Kim, N. R., Lee, E. S., Seong, G. J., Kim, J. H., An, H. G., & Kim, C. Y. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-5053 · Cited by 264
Does Retinal Ganglion Cell Loss Precede Visual Field Loss in Glaucoma?
Hood, D. C. (2019) · Journal of Glaucoma · doi:10.1097/ijg.0000000000001380 · Cited by 29
Metadata
- Authors
- Schlottmann, P. G., De Cilla, S., Greenfield, D. S., Caprioli, J., & Garway-Heath, D. F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2004-06-01
- Volume
- 45
- Issue
- 6
- Pages
- 1823
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2159305204
- Cited by
- 171
- References
- 0
- FWCI
- 17.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.