CoChat

Temporal Changes in Optical Quality of Air–Tear Film Interface at Anterior Cornea after Blink

Monte´s-Mico´, Robert, Alio´, Jorge L., Mun~oz, Gonzalo, Charman, W. Neil · 2004 · Investigative Opthalmology & Visual Science
Cited by 167

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To examine temporal changes in the optical quality of the air-tear film interface at the anterior cornea after a blink. METHODS: Corneal aberrations were determined in fifteen healthy subjects at 1 second time intervals after a blink, up to a total elapsed time of 15 seconds. Corneal aberrations were obtained from corneal elevation maps measured using a Tomey TMS-2N topographer and custom software. All data were decomposed using Zernike polynomials to yield the root mean square (RMS) wavefront deviations, in micrometers, for two pupil diameters (3 and 7 mm). RESULTS: Total wavefront aberration decreased slightly with time in the first few seconds after a blink for both pupil diameters, reaching a minimum after approximately 6 seconds. Thereafter aberrations increased steadily, exceeding the immediate postblink level after approximately 10 seconds. CONCLUSIONS: In normal subjects, the contribution of the anterior cornea to the overall ocular aberration remains reasonably stable over the normal interblink interval (approximately 4 seconds) but rises to levels which could perceptibly degrade retinal image quality under circumstances where the interblink interval is increased to exceed 10 seconds, as may occur during the use of visual display screens or when performing difficult tasks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.03-0839

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 167

Metadata

Authors
Monte´s-Mico´, R., Alio´, J. L., Mun~oz, G., & Charman, W. N.
Venue
Investigative Opthalmology & Visual Science
Published
2004-06-01
Volume
45
Issue
6
Pages
1752
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1991938795
Cited by
167
References
4
FWCI
8.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temporal Changes in Optical Quality of Air–Tear Film Interface at Anterior Cornea after Blink. https://app.cochat.ai/papers/10.1167/iovs.03-0839
The paper
Monte´s-Mico´, R., Alio´, J. L., Mun~oz, G., & Charman, W. N. (2004). Temporal Changes in Optical Quality of Air–Tear Film Interface at Anterior Cornea after Blink. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.03-0839

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.