Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record.

Dynamic Changes in the Tear Film in Dry Eyes

Monte´s-Mico´, Robert, Alio´, Jorge L., Charman, W. Neil · 2005 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To examine the dynamics of the tear film in patients with dry eye by measuring the wavefront aberrations of the anterior surface of the film. METHODS: Anterior surface aberrations for a 7-mm pupil were determined in 13 patients with dry eye at 1-second time intervals, for 15 seconds after a blink. The aberrations were calculated from the elevations provided by corneal topography. All data were decomposed using Zernike polynomials. Total, spherical, and comalike aberrations terms were studied separately. Results were compared with those in normal eyes. Outcome measures included comparison with clinical tear breakup time measurements. RESULTS: The total root mean square (RMS) wavefront aberration in patients with dry eye passed through in a minimum of 2.9 +/- 0.4 seconds after a blink in comparison to the minimum at 6.1 +/- 0.5 seconds in normal patients. In both groups, the minimum in total aberration appeared to be associated with similar changes in comalike aberrations, rather than in spherical aberrations, which increased monotonically with time. The time at which minimum RMS aberration occurred correlated reasonably well with the measured tear breakup times. CONCLUSIONS: Measurements of the dynamic changes in the optical aberrations introduced by the anterior tear film surface give valuable insights into tear film changes and may provide a convenient objective method for the diagnosis of dry eye.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.05-0017

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
Monte´s-Mico´, R., Alio´, J. L., & Charman, W. N.
Venue
Investigative Opthalmology & Visual Science
Published
2005-05-01
Volume
46
Issue
5
Pages
1615
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2008175380
Cited by
170
References
0
FWCI
10.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic Changes in the Tear Film in Dry Eyes. https://app.cochat.ai/papers/10.1167/iovs.05-0017
The paper
Monte´s-Mico´, R., Alio´, J. L., & Charman, W. N. (2005). Dynamic Changes in the Tear Film in Dry Eyes. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.05-0017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.