The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Retinal Microvascular Surgery: A Feasibility Study
Abstract
PURPOSE: To evaluate the feasibility of microvascular surgery at the level of the retinal vasculature. METHOD: Porcine eyes were used, and eyecups were prepared under an operating microscope. Several classic microvascular maneuvers were explored, such as vascular puncturing, catheterization, mobilization, intravascular injections, and various combinations of the same. Instruments used ranged from disposable 30-gauge needles to an Er:YAG laser. Commercially available 10-0 nylon sutures, fine polyimide tubes, and custom-made fine glass tubes were used for vascular catheterization. RESULTS: Puncturing, mobilization, catheterization, and intravascular injection of retinal arteries and veins were possible. The connection of two remote retinal vessels with a fine tube was also achieved with the combination of these maneuvers. CONCLUSIONS: The feasibility of performing several microvascular maneuvers on retinal arteries and veins was demonstrated in porcine eyes. Further experimentation and development of these findings in a living animal model could lead to the development of such microvascular maneuvers in humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, a handle mounted force sensor is not practical for vitreoretinal surgery.”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [25]
Citations
Cites
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
McAllister, I. L., Douglas, J. P., Constable, I. J., & Yu, D.-Y. (1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00156-1 · Cited by 167
Shah, G. K., Sharma, S., Fineman, M. S., Federman, J. L., Brown, M. M., & Brown, G. C. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00287-1 · Cited by 89
A Study of Surgical Approaches to Retinal Vascular Occlusions
Tang, W. M. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.138 · Cited by 84
Microvascular anastomosis with minimal suture and fibrin glue: Experimental and clinical study
Han, S., Kim, S. W., & Kim, W.-K. (1998) · Microsurgery · doi:10.1002/(sici)1098-2752(1998)18:5<306::aid-micr2>3.0.co;2-8 · Cited by 56
Characterization of vasomotion in porcine retinal arterioles
Hessellund, A., Jeppesen, P., Aalkjær, C., & Bek, T. (2003) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2003.00063.x · Cited by 50
Surgical Chorioretinal Venous Anastomosis for Ischemic Central Retinal Vein Occlusion
Peyman, G. A., Kishore, K., & Conway, M. D. (1999) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/1542-8877-19990901-03 · Cited by 44
Microvascular Anastomosis Using 2-Octyl Cyanoacrylate in the Rat Femoral Artery
Hall, W. W., Wrye, S. W., Banducci, D. R., & Ehrlich, P. (2000) · Annals of Plastic Surgery · doi:10.1097/00000637-200044050-00008 · Cited by 42
Retinal Surgery for Treatment of Central Retinal Vein Occlusion
Weiss, J. N. (2000) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/1542-8877-20000301-18 · Cited by 36
Hartnett, M. E., & Hirose, T. (1998) · Retina · doi:10.1097/00006982-199818020-00005 · Cited by 33
Cited by
Beisenova, A., Issatayeva, A., Iordachita, I. I., Blanc, W., Molardi, C., & Tosi, D. (2019) · Optics Express · doi:10.1364/oe.27.022074 · Cited by 99
Robotic Assisted Cannulation of Occluded Retinal Veins
de Smet, M. D., Meenink, T. C. M., Janssens, T., Valerie, V., Naus, G. J. L., Beelen, M. J., Meers, C., Jonckx, B., & Stassen, J.-M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162037 · Cited by 95
“In live surgery, cannulation has been limited to vessels located close to the optic nerve where a larger lumen and relative stability provided by adventitial fixation to the optic nerve facilitate the procedure [18,20,21].”
BackgroundInfluential3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery
Gonenc, B., Chamani, A., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2694965 · Cited by 72
“Excessive peeling forces can damage retinal vasculature [10] and cause serious complications such as iatrogenic retinal breaks [11], vitreous hemorrhage [12] and subretinal hemorrhage [13], leading to potentially irreversible damage and loss of vision.”
Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54
“Similarly, retinal veins and other tissues can be damaged during manipulation [6].”
BackgroundKang, J. U., Huang, Y., Cha, J., Zhang, K., Ibrahim, Z., Lee, W. P. A., Brandacher, G., & Gehlbach, P. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.081403 · Cited by 49
Metadata
- Authors
- Tsilimbaris, M. K., Lit, E. S., & D’Amico, D. J.
- Affiliations
- Massachusetts Eye and Ear Infirmary (US)
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2004-06-01
- Volume
- 45
- Issue
- 6
- Pages
- 1963
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2046435127
- Cited by
- 27
- References
- 17
- Citations by year
- 2026: 1 · 2025: 1 · 2019: 2 · 2017: 3 · 2016: 3 · 2015: 2 · 2014: 2 · 2013: 1 · 2012: 5
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Keywords
- retinal arteries, retinal veins, vascular catheterization, intravascular injection, porcine eye model, surgical feasibility
- MeSH terms
- Anastomosis, Surgical, Animals, Catheterization, Peripheral, Feasibility Studies, Injections, Microsurgery, Retinal Vessels, Ophthalmologic Surgical Procedures, Swine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retinal Microvascular Surgery: A Feasibility Study. https://app.cochat.ai/papers/10.1167/iovs.03-0874
- The paper
- Tsilimbaris, M. K., Lit, E. S., & D’Amico, D. J. (2004). Retinal Microvascular Surgery: A Feasibility Study. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.03-0874
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.