Retinal Microvascular Surgery: A Feasibility Study
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the feasibility of microvascular surgery at the level of the retinal vasculature. METHOD: Porcine eyes were used, and eyecups were prepared under an operating microscope. Several classic microvascular maneuvers were explored, such as vascular puncturing, catheterization, mobilization, intravascular injections, and various combinations of the same. Instruments used ranged from disposable 30-gauge needles to an Er:YAG laser. Commercially available 10-0 nylon sutures, fine polyimide tubes, and custom-made fine glass tubes were used for vascular catheterization. RESULTS: Puncturing, mobilization, catheterization, and intravascular injection of retinal arteries and veins were possible. The connection of two remote retinal vessels with a fine tube was also achieved with the combination of these maneuvers. CONCLUSIONS: The feasibility of performing several microvascular maneuvers on retinal arteries and veins was demonstrated in porcine eyes. Further experimentation and development of these findings in a living animal model could lead to the development of such microvascular maneuvers in humans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, a handle mounted force sensor is not practical for vitreoretinal surgery.”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [25]
Citations
Cites
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
McAllister, I. L., Douglas, J. P., Constable, I. J., & Yu, D.-Y. (1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00156-1 · Cited by 167
Shah, G. K., Sharma, S., Fineman, M. S., Federman, J. L., Brown, M. M., & Brown, G. C. (2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)00287-1 · Cited by 89
A Study of Surgical Approaches to Retinal Vascular Occlusions
Tang, W. M. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.1.138 · Cited by 84
Microvascular anastomosis with minimal suture and fibrin glue: Experimental and clinical study
Han, S., Kim, S. W., & Kim, W.-K. (1998) · Microsurgery · doi:10.1002/(sici)1098-2752(1998)18:5<306::aid-micr2>3.0.co;2-8 · Cited by 56
Characterization of vasomotion in porcine retinal arterioles
Hessellund, A., Jeppesen, P., Aalkjær, C., & Bek, T. (2003) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.2003.00063.x · Cited by 50
Surgical Chorioretinal Venous Anastomosis for Ischemic Central Retinal Vein Occlusion
Peyman, G. A., Kishore, K., & Conway, M. D. (1999) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/1542-8877-19990901-03 · Cited by 44
Microvascular Anastomosis Using 2-Octyl Cyanoacrylate in the Rat Femoral Artery
Hall, W. W., Wrye, S. W., Banducci, D. R., & Ehrlich, P. (2000) · Annals of Plastic Surgery · doi:10.1097/00000637-200044050-00008 · Cited by 42
Retinal Surgery for Treatment of Central Retinal Vein Occlusion
Weiss, J. N. (2000) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/1542-8877-20000301-18 · Cited by 36
Hartnett, M. E., & Hirose, T. (1998) · Retina · doi:10.1097/00006982-199818020-00005 · Cited by 33
Cited by
Beisenova, A., Issatayeva, A., Iordachita, I. I., Blanc, W., Molardi, C., & Tosi, D. (2019) · Optics Express · doi:10.1364/oe.27.022074 · Cited by 99
Robotic Assisted Cannulation of Occluded Retinal Veins
de Smet, M. D., Meenink, T. C. M., Janssens, T., Vanheukelom, V., Naus, G. J. L., Beelen, M. J., Meers, C., Jonckx, B., & Stassen, J.-M. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162037 · Cited by 94
“In live surgery, cannulation has been limited to vessels located close to the optic nerve where a larger lumen and relative stability provided by adventitial fixation to the optic nerve facilitate the procedure [18,20,21].”
BackgroundInfluential3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery
Gonenc, B., Chamani, A., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2694965 · Cited by 72
“Excessive peeling forces can damage retinal vasculature [10] and cause serious complications such as iatrogenic retinal breaks [11], vitreous hemorrhage [12] and subretinal hemorrhage [13], leading to potentially irreversible damage and loss of vision.”
Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54
“Similarly, retinal veins and other tissues can be damaged during manipulation [6].”
BackgroundKang, J. U., Huang, Y., Cha, J., Zhang, K., Ibrahim, Z., Lee, W. P. A., Brandacher, G., & Gehlbach, P. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.081403 · Cited by 49
Endovascular Cannulation With a Microneedle for Central Retinal Vein Occlusion
Kadonosono, K., Yamane, S., Arakawa, A., Inoue, M., Yamakawa, T., Uchio, E., Yanagi, Y., & Amano, S. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.2585 · Cited by 47
“Because CRVO is thought to be caused by thrombus within the central retinal vein in the lamina cribrosa, recanalization is a reasonable treatment strategy; however, no endovascular treatment has been established for vascular occlusions in the human retina.(4-8) Green et al(9) demonstrated that CRVO is caused by thromb…”
BackgroundGonenc, B., Chae, J. J., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · Sensors · doi:10.3390/s17102195 · Cited by 46
“In porcine eyes, it was shown that puncturing larger proximal vessels is technically easier than piercing the smaller veins more distal to the optic nerve after they have branched [14].”
BackgroundPortability and applicability of virtual fixtures across medical and manufacturing tasks
Lin, H., Mills, K., Kazanzides, P., Hager, G. D., Marayong, P., Okamura, A. M., & Karam, R. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641188 · Cited by 39
Retinal vessel cannulation with an image-guided handheld robot
Becker, B. C., Voros, S., Lobes, L. A., Handa, J. T., Hager, G. D., & Riviere, C. N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626493 · Cited by 40
“It has been noted that larger vessels are easier to puncture than smaller vessels more distal to the optic nerve [5].”
BackgroundAn Experimental Study of Retinal Endovascular Surgery with a Microfabricated Needle
Kadonosono, K., Arakawa, A., Yamane, S., Uchio, E., & Yanagi, Y. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7327 · Cited by 29
“Retinal vein cannulation is one of the surgical procedures that are performed on the retinal vasculature.(12,13) It involves puncture, injection, and cannulation, and has been performed in studies on both animal and human eyes.”
BackgroundBecker, B. C., Yang, S., MacLachlan, R. A., & Riviere, C. N. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290813 · Cited by 31
Force-based puncture detection and active position holding for assisted retinal vein cannulation
Gonenc, B., Tran, N., Riviere, C. N., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2015) · IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI) · doi:10.1109/mfi.2015.7295828 · Cited by 26
Farooq, M. U., Xu, B., & Ko, S. Y. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0666-x · Cited by 25
Gonenc, B., Gehlbach, P. L., Handa, J. T., Taylor, R. H., & Iordachita, I. I. (2014) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2014.6913784 · Cited by 28
“Unintentional motion and application of excessive forces can damage retinal veins [2] and give rise to serious complications such as iatrogenic retinal breaks [3], vitreous hemorrhage, or subretinal”
In VivoRetinal Vein Bypass Surgery in a Porcine Model
Shen, L., Chen, Y., Cheng, D., Zhang, C., Jiang, L., Hong, M., & Kang, Q. (2014) · Current Eye Research · doi:10.3109/02713683.2014.997887 · Cited by 20
“bility of simulated bypass of an arterial segment with a piece of 10-0 nylon suture in porcine eye.(15) In a previous study(15,19,20), the feasibility of retinal vein”
BackgroundMethodPournaras, C. J., Petropoulos, I. K., Pournaras, J.-A. C., Stangos, A. N., Gilodi, N., & Rungger‐Brändle, E. (2012) · Retina · doi:10.1097/iae.0b013e318241ae55 · Cited by 13
Effects of micro-vibratory modulation during robot-assisted membrane peeling
Gonenc, B., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353912 · Cited by 13
“Application of forces beyond this level can damage retinal veins [2] and give rise to serious complications such as iatrogenic retinal injury and breaks [3], vitreous hemorrhage, or subretinal hemorrhage [4] leading to potentially irreversible damage and loss of vision.”
BackgroundBypassing Occluded Retinal Main Vessel Segments in Isolated Arterially Perfused Caprine Eyes
Shen, L., Chen, Y., Wei, L., Wu, W. D., Wang, Z.-Y., Liu, Y., Lü, F., & Qu, J. (2009) · Current Eye Research · doi:10.1080/02713680902862989 · Cited by 10
Kuhli-Hattenbach, C., Puchta, J., & Hilgenberg, I. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8486 · Cited by 8
“Several experimental studies have demonstrated that probing and catheterization of the vascular lumen of retinal vessels may be achieved with sutures, glass tubes, or polyimide tubes.28–32 Since the maximally achievable reduction in size of a cannula depends on stability, previous techniques using materials such as bo…”
BackgroundResultInfluentialKim, N. J., Harris, A., Elghouche, A. N., Gama, W., & Siesky, B. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-29346-2_9 · Cited by 9
Safe tissue manipulation in retinal microsurgery via motorized instruments with force sensing
Gonenc, B., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234070 · Cited by 8
“Application of excessive forces with abrupt changes may damage retinal vasculature [2], and lead to serious complications, such as iatrogenic retinal injury and breaks [3], vitreous hemorrhage, or subretinal hemorrhage [4].”
Tourville, É., SCHACHAT, A. P., Hansen, L. L., Hoerauf, H., Burton, M. J., Gregor, Z. J., Brown, G. C., & Brown, M. M. (2007) · Springer eBooks · doi:10.1007/978-3-540-29542-6_21 · Cited by 5
Asami, T., Kaneko, H., Miyake, K., Ota, I., Miyake, G., Kato, S. X., Yasuda, S., Iwase, T., Ito, Y., & Terasaki, H. (2016) · Translational Vision Science & Technology · doi:10.1167/tvst.5.5.9 · Cited by 3
In vivo redirection of retinal blood flow into borosilicate micro-cannulas in rabbits
Christoforidis, J. B., Warden, S. M., DeMattia, M., & D’Amico, D. J. (2006) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-005-0214-1 · Cited by 3
“Using porcine eyes without blood flow, a combination of maneuvers was used to redirect a vascular route with polyimide tubing after puncturing and cannulating two separate vessels [6].”
BackgroundMethodSelf-citationVision-Based Control of a Handheld Micromanipulator for Robot-Assisted Retinal Surgery
Becker, B. C. (2012) · KiltHub Repository · doi:10.1184/r1/6724241 · Cited by 3
Application of polyimides as coatings in catheters
Zhu, J., Jin, H., Ao, S., Dai, W., Cheng, S., Yin, S., Kuang, T., Luo, L., Xiao, H., Zhou, J., et al. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-29911-7.00006-0
Su, H., Sun, Z.-Q., Qiu, Y.-C., Zhang, Y., Luo, J., Liu, F., Yang, J., Zhou, X.-Y., Zhang, Y., & Zhang, Y.-M. (2026) · Chinese Journal of Polymer Science · doi:10.1007/s10118-026-3661-2
Metadata
- Authors
- Tsilimbaris, M. K., Lit, E. S., & D’Amico, D. J.
- Affiliations
- Massachusetts Eye and Ear Infirmary (US)
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2004-06-01
- Volume
- 45
- Issue
- 6
- Pages
- 1963
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2046435127
- Cited by
- 27
- References
- 17
- Citations by year
- 2026: 1 · 2025: 1 · 2019: 2 · 2017: 3 · 2016: 3 · 2015: 2 · 2014: 2 · 2013: 1 · 2012: 5
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Keywords
- retinal arteries, retinal veins, vascular catheterization, intravascular injection, porcine eye model, surgical feasibility
- MeSH terms
- Anastomosis, Surgical, Animals, Catheterization, Peripheral, Feasibility Studies, Injections, Microsurgery, Retinal Vessels, Ophthalmologic Surgical Procedures, Swine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.