Robotic Assisted Cannulation of Occluded Retinal Veins
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: To develop a methodology for cannulating porcine retinal venules using a robotic assistive arm after inducing a retinal vein occlusion using the photosensitizer rose bengal. METHODOLOGY: Retinal vein occlusions proximal to the first vascular branch point were induced following intravenous injection of rose bengal by exposure to 532nm laser light delivered by slit-lamp or endolaser probe. Retinal veins were cannulated by positioning a glass catheter tip using a robotically controlled micromanipulator above venules with an outer diameter of 80μm or more and performing a preset piercing maneuver, controlled robotically. The ability of a balanced salt (BSS) solution to remove an occlusion by repeat distention of the retinal vein was also assessed. RESULTS: Cannulation using the preset piercing program was successful in 9 of 9 eyes. Piercing using the micromanipulator under manual control was successful in only 24 of 52 attempts, with several attempts leading to double piercing. The best location for cannulation was directly proximal to the occlusion. Infusion of BSS did not result in the resolution of the occlusion. CONCLUSION: Cannulation of venules using a robotic microassistive arm can be achieved with consistency, provided the piercing is robotically driven. The model appears robust enough to allow testing of therapeutic strategies aimed at eliminating a retinal vein thrombus and its evolution over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Predictors of anti-VEGF treatment response in neovascular age-related macular degeneration
Finger, R. P., Wickremasinghe, S. S., Baird, P. N., & Guymer, R. H. (2014) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2013.03.009 · Cited by 144
Physiological tremor amplitude during retinal microsurgery
Singh, S. P. N., & Riviere, C. N. (2002) · Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342) · doi:10.1109/nebc.2002.999520 · Cited by 131
Retinal Microvascular Surgery: A Feasibility Study
Tsilimbaris, M. K., Lit, E. S., & D’Amico, D. J. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0874 · Cited by 27 · cited 4×
“In live surgery, cannulation has been limited to vessels located close to the optic nerve where a larger lumen and relative stability provided by adventitial fixation to the optic nerve facilitate the procedure [18,20,21].”
BackgroundInfluential
Cited by
First-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
Self-citationFirst-in-Human robot-assisted subretinal drug delivery under local anesthesia
Cehajic-Kapetanovic, J., Xue, K., Edwards, T. L., Meenink, T. C., Beelen, M. J., Naus, G. J., de Smet, M. D., & MacLaren, R. E. (2022) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2021.11.011 · Cited by 78
Self-citationLadha, R., Meenink, T., Smit, J., & de Smet, M. D. (2023) · Gene Therapy · doi:10.1038/s41434-021-00262-w · Cited by 42
Self-citationde Smet, M. D., Lynch, J. L., Dejneka, N. S., Keane, M., & Khan, I. J. (2018) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22233 · Cited by 23
“Robotic-assisted surgical solutions may mitigate these challenges by providing high positional stability in all primary directions.(31,32) Positional stability also eliminates the need to proceed quickly with the injection, a requirement of manual procedures that may limit the applicability of any transvitreal injecti…”
BackgroundRobot-assisted retinal surgery: overcoming human limitations
Xue, K., Edwards, T. L., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., de Smet, M. D., & MacLaren, R. E. (2019) · Retina Atlas · doi:10.1007/978-981-13-6214-9_11 · Cited by 18
Self-citation
Metadata
- Authors
- de Smet, M. D., Meenink, T. C. M., Janssens, T., Vanheukelom, V., Naus, G. J. L., Beelen, M. J., Meers, C., Jonckx, B., & Stassen, J.-M.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-09-27
- Volume
- 11
- Issue
- 9
- Pages
- e0162037
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2523797441
- Cited by
- 94
- References
- 3
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robotic Assisted Cannulation of Occluded Retinal Veins. https://app.cochat.ai/papers/10.1371/journal.pone.0162037
- The paper
- de Smet, M. D., Meenink, T. C. M., Janssens, T., Vanheukelom, V., Naus, G. J. L., Beelen, M. J., Meers, C., Jonckx, B., & Stassen, J.-M. (2016). Robotic Assisted Cannulation of Occluded Retinal Veins. PLOS ONE. https://doi.org/10.1371/journal.pone.0162037
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.