Determination of the Location of the Fovea on the Fundus
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate whether the distance between optic nerve head and fovea in healthy eyes determined by scanning laser ophthalmoscope may facilitate estimation of the location of the fovea relative to the optic disc in patients with macular disease. METHODS: The angular distance was measured, in horizontal and vertical directions, between the center of the optic nerve head and the fovea in 104 eyes of 104 healthy probands. For additional evaluation of intraindividual variation in 70 of these persons the contralateral eye was measured as well. RESULTS: The distance between the optic disc and the fovea differed vertically more than horizontally (-1.5 +/- 0.9 degrees [-3.65 to +0.65 degrees ] vs. 15.5 +/- 1.1 degrees [13.0-17.9 degrees ]). There was a mean angle between the fovea and the center of the optic disc versus the horizon of -5.6 +/- 3.3 degrees. The intraindividual difference between right and left eyes was markedly lower, with average angles being 0.2 +/- 1.3 degrees vertically and 0.0 +/- 1.1 degrees horizontally. CONCLUSIONS: The distance between the optic nerve head and the fovea does not allow for a meaningful determination of the location of the fovea in eyes in which morphologic changes have occurred. The angle of rotation of the fovea relatively to the center of the optic nerve head is relatively stable. Therefore, the size of a central scotoma can be determined by movement of the blind spot according to the change of the preferred retinal locus (PRL). In addition, the knowledge of the location of the fovea enables determination of the position in the contralateral eye of the same patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glaucomatous damage of the macula
Hood, D. C., Raza, A. S., de Moraes, C. G. V., Liebmann, J. M., & Ritch, R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.08.003 · Cited by 867
Waldstein, S. M., Vogl, W.-D., Bogunovic, H., Sadeghipour, A., Riedl, S., & Schmidt-Erfurth, U. (2020) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2020.1376 · Cited by 203
Initial Arcuate Defects within the Central 10 Degrees in Glaucoma
Hood, D. C., Raza, A. S., de Moraes, C. G. V., Odel, J. G., Greenstein, V. C., Liebmann, J. M., & Ritch, R. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5803 · Cited by 186
“For example, the location of the disc in relation to the fovea shows variation among individuals.(22,23) It is important to distinguish between the location of the receptors onto which the retinal image of a 10-2 test spot falls and the location of the RGCs activated by those receptors.”
BackgroundLi, Q., Joo, S. J., Yeatman, J. D., & Reinecke, K. (2020) · Scientific Reports · doi:10.1038/s41598-019-57204-1 · Cited by 183
“Since the mean blind spot diameter is around 4.5° ,25 , the center of the blind spots from our results is then 15.84° ± 0.96°, comparable to prior work, in which the blind spot locations are ranged between 14.33 ◦ and 15.52° 22,23,25 .”
ResultInfluentialTowards standardizing retinal optical coherence tomography angiography: a review
Sampson, D. M., Dubis, A. M., Chen, F. K., Zawadzki, R. J., & Sampson, D. D. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00740-9 · Cited by 179
Metadata
- Authors
- Rohrschneider, K.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2004-09-01
- Volume
- 45
- Issue
- 9
- Pages
- 3257
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1996693450
- Cited by
- 143
- References
- 0
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of the Location of the Fovea on the Fundus. https://app.cochat.ai/papers/10.1167/iovs.03-1157
- The paper
- Rohrschneider, K. (2004). Determination of the Location of the Fovea on the Fundus. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.03-1157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.