The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Shape of the Retinal Surface in Emmetropia and Myopia
Abstract
PURPOSE: To determine and compare the shapes of the retinas of emmetropic and myopic eyes. METHODS: Nonrotationally symmetrical ellipsoids were mathematically fitted to the retinal surfaces of 21 emmetropic and 66 myopic eyes (up to -12 D) of participants aged 18 to 36 years (mean, 25.5) using transverse axial and sagittal images derived from magnetic resonance imaging. RESULTS: The shapes of the ellipsoids varied considerably between subjects with similar refractive errors. The shapes were oblate (steepening toward the equator) in most of the emmetropic eyes (i.e., the axial dimensions of the ellipsoids were smaller than both the vertical and horizontal dimensions). As myopia increased, all ellipsoid dimensions increased with the axial dimension increasing more than the vertical dimension, which in turn increased more than the horizontal dimension (increases in approximate ratios 3:2:1). The relative difference in the increase of these dimensions meant that as the degree of myopia increased the retinal shape decreased in oblateness. However, few myopic eyes were prolate (flattening toward the equator). Independent of myopia, the ellipsoids were tilted about the vertical axis by 11 degrees +/- 13 degrees , and ellipsoid centers were decentered horizontally by 0.5 +/- 0.4 mm nasally and 0.2 +/- 0.5 mm inferiorly, relative to the fovea. CONCLUSIONS: In general both emmetropic and myopic retinas are oblate in shape, although myopic eyes less so. This finding may be relevant to theories implicating the peripheral retina in the development of myopia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Lam, C. S. Y., Tang, W. C., Tse, D. Y.-Y., Tang, Y. Y., & To, C. H. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303914 · Cited by 368
Age-related changes in optical and biometric characteristics of emmetropic eyes
Atchison, D. A., Markwell, E. L., Kasthurirangan, S., Pope, J. M., Smith, G., & Swann, P. G. (2008) · Journal of Vision · doi:10.1167/8.4.29 · Cited by 270
Self-citationMyopia and peripheral ocular aberrations
Mathur, A., Atchison, D. A., & Charman, W. N. (2009) · Journal of Vision · doi:10.1167/9.10.15 · Cited by 53
Self-citation
Metadata
- Authors
- Atchison, D. A., Pritchard, N., Schmid, K. L., Scott, D. H., Jones, C. E., & Pope, J. M.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2005-08-01
- Volume
- 46
- Issue
- 8
- Pages
- 2698
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1525224968
- Cited by
- 267
- References
- 3
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.