CoChat

ABCA4-Associated Retinal Degenerations Spare Structure and Function of the Human Parapapillary Retina

Open access
Cideciyan, Artur V., Swider, Malgorzata, Aleman, Tomas S., Sumaroka, Alexander, Schwartz, Sharon B., Roman, Marisa I., Milam, Ann H., Bennett, Jean, Stone, Edwin M., Jacobson, Samuel G. · 2005 · Investigative Opthalmology & Visual Science
Cited by 130

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

PURPOSE: To study the parapapillary retinal region in patients with ABCA4-associated retinal degenerations. METHODS: Patients with Stargardt disease or cone-rod dystrophy and disease-causing variants in the ABCA4 gene were included. Fixation location was determined under fundus visualization, and central cone-mediated vision was measured. Intensity and texture abnormalities of autofluorescence (AF) images were quantified. Parapapillary retina of an eye donor with ungenotyped Stargardt disease was examined microscopically. RESULTS: AF images ranged from normal, to spatially homogenous abnormal increase of intensity, to a spatially heterogenous speckled pattern, to variably sized patches of low intensity. A parapapillary ring of normal-appearing AF was visible at all disease stages. Quantitative analysis of the intensity and texture properties of AF images showed the preserved region to be an annulus, at least 0.6 mm wide, surrounding the optic nerve head. A similar region of relatively preserved photoreceptor nuclei was apparent in the donor retina. In patients with foveal fixation, there was better cone sensitivity at a parapapillary locus in the nasal retina than at the same eccentricity in the temporal retina. In patients with eccentric fixation, approximately 30% had a preferred retinal locus in the parapapillary retina. CONCLUSIONS: Human retinal degenerations caused by ABCA4 mutations spare the structure of retina and RPE in a circular parapapillary region that commonly serves as the preferred fixation locus when central vision is lost. The retina between fovea and optic nerve head could serve as a convenient, accessible, and informative region for structural and functional studies to determine natural history or outcome of therapy in ABCA4-associated disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.05-0805

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Cideciyan, A. V., Swider, M., Aleman, T. S., Sumaroka, A., Schwartz, S. B., Roman, M. I., Milam, A. H., Bennett, J., Stone, E. M., & Jacobson, S. G.
Venue
Investigative Opthalmology & Visual Science
Published
2005-12-01
Volume
46
Issue
12
Pages
4739
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2077069863
Cited by
130
References
10
FWCI
2.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.