The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Visual Acuities “Hand Motion” and “Counting Fingers” Can Be Quantified with the Freiburg Visual Acuity Test
Abstract
PURPOSE: The visual acuity (VA) of patients with very low vision is classified using the semiquantitative scale "counting fingers" (CF), "hand motion" (HM), "light perception" (LP), and "no light perception." More quantitative measures would be desirable, especially for clinical studies. The results of clinical VA measurements, Early Treatment Diabetic Retinopathy Study (ETDRS) charts, and the Freiburg Visual Acuity Test (FrACT) were compared. The FrACT is a computerized visual acuity test that can present very large Landolt C optotypes when necessary. METHODS: Examined were 100 eyes of 100 patients with various eye diseases (e.g., diabetic retinopathy, ARMD), covering a range of VAs from LP to decimal 0.32. The FrACT optotypes were presented on a 17-inch LCD monitor with random orientation. After extensive training, two ETDRS and FrACT measurements were obtained. The testing distance was 50 or 100 cm. RESULTS: ETDRS and FrACT coincided closely for VA > or = 0.02 (n = 80). ETDRS measures were successfully obtainable down to CF (at 30 cm; test-retest averaged over all patients, coefficient of variation [CV](ETDRS) = 9% +/- 8%), and FrACT provided reproducible measurements down to HM (test-retest CV(FrACT) =12% +/- 11%). For CF (n = 6), both ETDRS and FrACT resulted in a mean VA of 0.014 +/- 0.003 (range, 0.01-0.02). The VA results of FrACT for HM (n = 12) were 0.005 +/- 0.002 (range, 0.003-0.009); the individual values were highly reproducible. No results were obtainable for LP (n = 2). CONCLUSIONS: The three acuity procedures concur above a VA of 0.02. The results suggest that the category CF at 30 cm can be replaced by 0.014, using ETDRS or FrACT. Using FrACT, one can even reproducibly quantify VA in the HM-range, yielding a mean VA of 0.005.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual acuity impairment in patients with retinitis pigmentosa at age 45 years or older
Grover, S., Fishman, G. A., Anderson, R. J., Tozatti, M. S. V., Heckenlively, J. R., Weleber, R. G., Edwards, A. O., & Brown, J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90342-1 · Cited by 235
Cited by
Subretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Multi-system neurological disease is common in patients with OPA1 mutations
Yu-Wai-Man, P., Griffiths, P. G., Gorman, G. S., Lourenco, C. M., Wright, A. F., Auer-Grumbach, M., Toscano, A., Musumeci, O., Valentino, M. L., Caporali, L., et al. (2010) · Brain · doi:10.1093/brain/awq007 · Cited by 450
The Freiburg Visual Acuity Test-Variability unchanged by post-hoc re-analysis
Bach, M. (2006) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-006-0474-4 · Cited by 397
Self-citationda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359
Bonnan, M., Valentino, R., Debeugny, S., Merle, H., Fergé, J.-L., Mehdaoui, H., & Cabre, P. (2018) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2017-316286 · Cited by 337
Metadata
- Authors
- Schulze-Bonsel, K., Feltgen, N., Burau, H., Hansen, L., & Bach, M.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-03-01
- Volume
- 47
- Issue
- 3
- Pages
- 1236
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1980404110
- Cited by
- 994
- References
- 1
- FWCI
- 7.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.