Subretinal electronic chips allow blind patients to read letters and combine them to words
Open accessAbstract
A light-sensitive, externally powered microchip was surgically implanted subretinally near the macular region of volunteers blind from hereditary retinal dystrophy. The implant contains an array of 1500 active microphotodiodes ('chip'), each with its own amplifier and local stimulation electrode. At the implant's tip, another array of 16 wire-connected electrodes allows light-independent direct stimulation and testing of the neuron-electrode interface. Visual scenes are projected naturally through the eye's lens onto the chip under the transparent retina. The chip generates a corresponding pattern of 38 × 40 pixels, each releasing light-intensity-dependent electric stimulation pulses. Subsequently, three previously blind persons could locate bright objects on a dark table, two of whom could discern grating patterns. One of these patients was able to correctly describe and name objects like a fork or knife on a table, geometric patterns, different kinds of fruit and discern shades of grey with only 15 per cent contrast. Without a training period, the regained visual functions enabled him to localize and approach persons in a room freely and to read large letters as complete words after several years of blindness. These results demonstrate for the first time that subretinal micro-electrode arrays with 1500 photodiodes can create detailed meaningful visual perception in previously blind individuals.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Striem-Amit et al. (2012a) found participants performed better than in experiments with tactile SSDs and retinal prostheses.
“Participants performed better than in experiments with tactile SSDs (Chebat et al., 2007, Sampaio et al., 2001), retinal prostheses (Zrenner et al., 2010) and 55% showed acuity higher than the threshold for blindness (see also Levy-Tzedek, Riemer, & Amedi, 2014).”
From Designing sensory-substitution devices: Principles, pitfalls and potential1 (2016) · cites this paper as Zrenner et al., 2010
Only one subretinal prosthesis, the Alpha IMS implant and its successor Alpha AMS, have received marketing approval (CE mark).
“Today, only one subretinal prosthesis, the Alpha IMS implant (figure 5(b)) and its successor Alpha AMS (Retina Implant AG), have received marketing approval (CE mark) [52,53].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [52]
Most clinical neural interfaces function in a monopolar configuration with a common and distant return ground placed several millimetres away.
“Most clinical neural interfaces function in a monopolar configuration with a common and distant return ground placed several millimetres away [9-12].”
From Three-dimensional multilayer concentric bipolar electrodes restrict spatial activation in optic nerve stimulation (2022) · cites this paper as [12]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Causes and Prevalence of Visual Impairment Among Adults in the UnitedStates
(2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.477 · Cited by 2,616 · see citing works
Schulze-Bonsel, K., Feltgen, N., Burau, H., Hansen, L. L., & Bach, M. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-0981 · Cited by 1,001 · see citing works
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 726 · see citing works
Self-citationThe Artificial Silicon Retina Microchip for the Treatment of VisionLoss From Retinitis Pigmentosa
Chow, A. Y. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.460 · Cited by 512 · see citing works
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · see citing works
Retinal remodeling during retinal degeneration
Jones, B. W., & Marc, R. E. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.03.006 · Cited by 430 · see citing works
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. A. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 330 · see citing works
Electrical multisite stimulation of the isolated chicken retina
Stett, A., Barth, W., Weiss, S., Haemmerle, H., & Zrenner, E. (2000) · Vision Research · doi:10.1016/s0042-6989(00)00005-5 · Cited by 259 · see citing works
Self-citationVisual Performance Using a Retinal Prosthesis in Three Subjects With Retinitis Pigmentosa
Yanai, D., Weiland, J. D., Mahadevappa, M., Greenberg, R. J., Fine, I., & Humayun, M. S. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.01.027 · Cited by 233 · see citing works
Stabilized Images on the Retina
Pritchard, R. M. (1961) · Scientific American · doi:10.1038/scientificamerican0661-72 · Cited by 209 · see citing works
Fujikado, T., Morimoto, T., Kanda, H., Kusaka, S., Nakauchi, K., Ozawa, M., Matsushita, K., Sakaguchi, H., Ikuno, Y., Kamei, M., et al. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-007-0563-z · Cited by 147 · see citing works
Responses of ganglion cells to repetitive electrical stimulation of the retina
Jensen, R. J., & Rizzo, J. F. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s01 · Cited by 121 · see citing works
Besch, D., Sachs, H., Szurman, P., Gülicher, D., Wilke, R. G. H., Reinert, S., Zrenner, E., Bartz‐Schmidt, K. U., & Gekeler, F. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.131961 · Cited by 115 · see citing works
Self-citationTemporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113 · see citing works
Retinal prostheses: current challenges and future outlook
Winter, J. O., Cogan, S. F., & Rizzo, J. F. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207781494403 · Cited by 109 · see citing works
A CMOS Chip With Active Pixel Array and Specific Test Features for Subretinal Implantation
Rothermel, A., Liu, L., Aryan, N. P., Fischer, M. D., Wuenschmann, J., Kibbel, S., & Harscher, A. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2007436 · Cited by 109 · see citing works
Self-citationSpatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95 · see citing works
Visual resolution with retinal implants estimated from recordings in cat visual cortex
Eckhorn, R., Wilms, M., Schanze, T., Eger, M., Hesse, L., Eysel, U. T., Kisvárday, Z. F., Zrenner, E., Gekeler, F., Schwahn, H., et al. (2006) · Vision Research · doi:10.1016/j.visres.2006.01.034 · Cited by 94 · see citing works
Self-citationSpatial updating and the maintenance of visual constancy
Klier, E. M., & Angelaki, D. E. (2008) · Neuroscience · doi:10.1016/j.neuroscience.2008.07.079 · Cited by 94 · see citing works
Cortical Activation Via an Implanted Wireless Retinal Prosthesis
Walter, P., ́rday, Z. ́. F. K., Görtz, M., Alteheld, N., Rößler, G., Stieglitz, T., & Eysel, U. T. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0924 · Cited by 92 · see citing works
Understanding the origin of visual percepts elicited by electrical stimulation of the human retina
Weiland, J. D., Humayun, M. S., Dagnelie, G., de Juan, E., Greenberg, R. J., & Iliff, N. T. (1999) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170050337 · Cited by 90 · see citing works
A method and technical equipment for an acute human trial to evaluate retinal implant technology
Hornig, R., Laube, T., Walter, P., Velikay‐Parel, M., Bornfeld, N., Feucht, M., Akguel, H., Rößler, G., Alteheld, N., Notarp, D. L., et al. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/014 · Cited by 77 · see citing works
Zhou, J., Woo, S. J., Park, S. I., Kim, E., Seo, J.-M., Chung, H., & Kim, S. J. (2008) · BioMed Research International · doi:10.1155/2008/547428 · Cited by 74 · see citing works
Long-term survival of retinal cell cultures on retinal implant materials
Guenther, E., Tröger, B., Schlosshauer, B., & Zrenner, E. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00128-5 · Cited by 71 · see citing works
Self-citationBasic Quantitative Assessment of Visual Performance in Patients with Very Low Vision
Bach, M., Wilke, M., Wilhelm, B., Zrenner, E., & Wilke, R. G. H. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3512 · Cited by 70 · see citing works
Self-citationDeMarco, P. J., Yarbrough, G. L., Yee, C. W., McLean, G. Y., Sagdullaev, B. T., Ball, S. L., & McCall, M. A. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0811 · Cited by 64 · see citing works
Stett, A., Mai, A., & Herrmann, T. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s02 · Cited by 59 · see citing works
Self-citationA CMOS retinal neurostimulator capable of focussed, simultaneous stimulation
Dommel, N., Wong, Y. T., Lehmann, T., Dodds, C. W. D., Lovell, N. H., & Suaning, G. J. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/035006 · Cited by 54 · see citing works
�ber Fixationsbreite und Fixationsfrequenz beim Lesen gerichteter Konturen
Aulhorn, E. (1953) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00363531 · Cited by 52 · see citing works
Fornos, A. P., Sommerhalder, J., Pittard, A., Safran, A. B., & Pelizzone, M. (2008) · Vision Research · doi:10.1016/j.visres.2008.04.027 · Cited by 50 · see citing works
Schmid, H., Herrmann, T., Köhler, K., et al. (2009) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2008.12.013 · Cited by 45 · see citing works
Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit
Gerding, H., Benner, F. P., & Taneri, S. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s06 · Cited by 44 · see citing works
Sachs, H. G., Schanze, T., Brunner, U., Sailer, H., & Wiesenack, C. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/008 · Cited by 36 · see citing works
Self-citationFirst results of a study on a completely implanted retinal prosthesis in blind humans
Koch, C., Mokwa, W., Goertz, M., et al. (2008) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2008.4716667 · Cited by 30 · see citing works
Visual Perception After Long-Term Implantation of a Retinal Implant
Richard, G., Keserü, M., Feucht, M., Post, N. H., & Hornig, R. (2008) · Investigative Ophthalmology & Visual Science · Cited by 23 · see citing works
Testing Visual Functions in Patients with Visual Prostheses
Wilke, R. G. H., Bach, M., Wilhelm, B., Durst, W., Trauzettel‐Klosinski, S., & Zrenner, E. (2007) · Springer eBooks · doi:10.1007/978-0-387-49331-2_5 · Cited by 21 · see citing works
Self-citationPreliminary Results from Argus II Feasibility Study: A 60 Electrode Epiretinal Prosthesis
Humayun, M. S. (2009) · Investigative Ophthalmology & Visual Science · Cited by 19 · see citing works
da Cruz, L., Coley, B., Christopher, P., Merlini, F., Wuyyuru, V., Sahel, J., Stanga, P. E., Filley, E., & Dagnelie, G. (2010) · Investigative Ophthalmology & Visual Science · Cited by 19 · see citing works
Dynamics of Visual Perception Upon Electrical Stimulation of the Retina
Fornos, A. P., Sommerhalder, J., & Pelizzone, M. (2010) · Investigative Ophthalmology & Visual Science · Cited by 9 · see citing works
Walter, P., Mokwa, W., Messner, A., et al. (2008) · Investigative Ophthalmology & Visual Science · Cited by 5 · see citing works
Preoperative 3D Planning of Implantation of a Subretinal Prosthesis Using MRI Data
Kusnyerik, Á., Greppmaier, U., Klose, U., et al. (2008) · Investigative Ophthalmology & Visual Science · Cited by 3 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Non-syndromic retinitis pigmentosa
Verbakel, S. K., van Huet, R. A. C., Boon, C. J. F., den Hollander, A. I., Collin, R. W. J., Klaver, C. C. W., Hoyng, C. B., Roepman, R., & Klevering, B. J. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.03.005 · Cited by 973 · see citing works
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705 · see citing works
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473 · see citing works
Self-citationSubretinal visual implant alpha IMS - clinical trial interim report
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Chee, C. K., Cottriall, C. L., Gekeler, F., Groppe, M., Jackson, T. L., MacLaren, R. E., Koitschev, A., et al. (2015) · Vision Research · doi:10.1016/j.visres.2015.03.001 · Cited by 387 · see citing works
Self-citationda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · see citing works
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351 · see citing works
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333 · see citing works
Dynamic Stimulation of Visual Cortex Produces Form Vision in Sighted and Blind Humans
Beauchamp, M. S., Oswalt, D., Sun, P., Foster, B. L., Magnotti, J. F., Niketeghad, S., Pouratian, N., Bosking, W. H., & Yoshor, D. (2020) · Cell · doi:10.1016/j.cell.2020.04.033 · Cited by 257 · see citing works
“Our work is related to previous work on form vision with retinal (Klauke et al., 2011; Rizzo et al., 2003a, 2003b; Shivdasani et al., 2017; Zrenner et al., 2011) and cortical visual prostheses (Dobelle et al.”
ResultRetinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272 · see citing works
Photovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227 · see citing works
An update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223 · see citing works
Self-citationMaidenbaum, S., Abboud, S., & Amedi, A. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.11.007 · Cited by 230 · see citing works
Emerging therapies for inherited retinal degeneration
Scholl, H. P. N., Strauss, R. W., Singh, M. S., Dalkara, D., Roska, B., Picaud, S., & Sahel, J.-A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2838 · Cited by 219 · see citing works
Stingl, K., Schippert, R., Bartz-Schmidt, K. U., Besch, D., Cottriall, C. L., Edwards, T. L., Gekeler, F., Greppmaier, U., Kiel, K., Koitschev, A., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00445 · Cited by 198 · see citing works
Advances in retinal prosthesis systems
Bloch, E., Luo, Y., & da Cruz, L. (2019) · Therapeutic Advances in Ophthalmology · doi:10.1177/2515841418817501 · Cited by 201 · see citing works
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193 · see citing works
Self-citationThe functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189 · see citing works
LiGluR restores visual responses in rodent models of inherited blindness
Caporale, N., Kolstad, K. D., Lee, T., Tochitsky, I., Dalkara, D., Trauner, D., Kramer, R., Dan, Y., Isacoff, E. Y., & Flannery, J. G. (2011) · Molecular Therapy · doi:10.1038/mt.2011.103 · Cited by 182 · see citing works
Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis
Ferlauto, L., Airaghi Leccardi, M. J. I., Chenais, N. A. L., Gilliéron, S. C. A., Vagni, P., Bevilacqua, M., Wolfensberger, T. J., Sivula, K., & Ghezzi, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03386-7 · Cited by 183 · see citing works
Dorn, J. D., Ahuja, A. K., Caspi, A., da Cruz, L., Dagnelie, G., Sahel, J.-A., Greenberg, R. J., McMahon, M. J., & Argus II Study Group, F. T. (2013) · JAMA Ophthalmology · doi:10.1001/2013.jamaophthalmol.221 · Cited by 177 · see citing works
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163 · see citing works
Improving the spatial resolution of epiretinal implants by increasing stimulus pulse duration
Weitz, A. C., Nanduri, D., Behrend, M. R., Gonzalez-Calle, A., Greenberg, R. J., Humayun, M. S., Chow, R. H., & Weiland, J. D. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac4877 · Cited by 154 · see citing works
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2019) · Scientific Reports · doi:10.1038/s41598-019-45416-4 · Cited by 143 · see citing works
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155 · see citing works
Self-citationRetinal output changes qualitatively with every change in ambient illuminance
Tikidji-Hamburyan, A., Reinhard, K., Seitter, H., Hovhannisyan, A., Procyk, C. A., Allen, A. E., Schenk, M., Lucas, R. J., & Münch, T. A. (2015) · Nature Neuroscience · doi:10.1038/nn.3891 · Cited by 134 · see citing works
Electronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133 · see citing works
‘Visual’ Acuity of the Congenitally Blind Using Visual-to-Auditory Sensory Substitution
Striem-Amit, E., Guendelman, M., & Amedi, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033136 · Cited by 117 · see citing works
Designing sensory-substitution devices: Principles, pitfalls and potential1
Kristjánsson, Á., Moldoveanu, A., Jóhannesson, Ó. I., Balan, O., Spagnol, S., Valgeirsdóttir, V. V., & Unnthorsson, R. (2016) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-160647 · Cited by 116 · see citing works
“, 2001), retinal prostheses (Zrenner et al., 2010) and 55% showed acuity higher than the threshold for blindness (see also Levy-Tzedek, Riemer, & Amedi, 2014).”
BackgroundTemporal properties of visual perception on electrical stimulation of the retina
Pérez Fornos, A., Sommerhalder, J., da Cruz, L., Sahel, J. A., Mohand-Said, S., Hafezi, F., & Pelizzone, M. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-9344 · Cited by 113 · see citing works
Retinal gene therapy: surgical vector delivery in the translation to clinical trials
Ochakovski, G. A., Bartz-Schmidt, K. U., & Fischer, M. D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00174 · Cited by 110 · see citing works
Self-citationElectric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants
Wilke, R. G. H., Moghadam, G. K., Lovell, N. H., Suaning, G. J., & Dokos, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/4/046016 · Cited by 110 · see citing works
Self-citationChenais, N. A. L., Airaghi Leccardi, M. J. I., & Ghezzi, D. (2021) · Communications Materials · doi:10.1038/s43246-021-00133-2 · Cited by 110 · see citing works
Beyeler, M., Rokem, A., Boynton, G. M., & Fine, I. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa795e · Cited by 102 · see citing works
Artificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90 · see citing works
Erickson-Davis, C., & Korzybska, H. (2021) · PLoS ONE · doi:10.1371/journal.pone.0229189 · Cited by 83 · see citing works
Factors Affecting Perceptual Thresholds in a Suprachoroidal Retinal Prosthesis
Shivdasani, M. N., Sinclair, N. C., Dimitrov, P. N., Varsamidis, M., Ayton, L. N., Luu, C. D., Perera, T., McDermott, H. J., & Blamey, P. J. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14396 · Cited by 78 · see citing works
Bioengineering strategies for restoring vision
Cehajic-Kapetanovic, J., Singh, M. S., Zrenner, E., & MacLaren, R. E. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00836-4 · Cited by 79 · see citing works
Self-citationCharacteristics of prosthetic vision in rats with subretinal flat and pillar electrode arrays
Ho, E., Lei, X., Flores, T., Lorach, H., Huang, T., Galambos, L., Kamins, T., Harris, J., Mathieson, K., & Palanker, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab34b3 · Cited by 65 · see citing works
Stimulation strategies for improving the resolution of retinal prostheses
Tong, W., Meffin, H., Garrett, D. J., & Ibbotson, M. R. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00262 · Cited by 66 · see citing works
Photovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63 · see citing works
Bendali, A., Rousseau, L., Lissorgues, G., Scorsone, E., Djilas, M., Dégardin, J., Dubus, E., Fouquet, S., Benosman, R., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.018 · Cited by 66 · see citing works
Villalobos, J., Nayagam, D. A. X., Allen, P. J., McKelvie, P., Luu, C. D., Ayton, L. N., Freemantle, A. L., McPhedran, M., Basa, M., McGowan, C. C., et al. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-10843 · Cited by 63 · see citing works
The appearance of phosphenes elicited using a suprachoroidal retinal prosthesis
Sinclair, N. C., Shivdasani, M. N., Perera, T., Gillespie, L. N., McDermott, H. J., Ayton, L. N., Blamey, P. J., & for the Bionic Vision Australia Consortium (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.15-18991 · Cited by 60 · see citing works
New Vision for Visual Prostheses
Farnum, A., & Pelled, G. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00036 · Cited by 58 · see citing works
Li, H., Su, X., Wang, J., Kan, H., Han, T., Zeng, Y., & Chai, X. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2017.11.001 · Cited by 59 · see citing works
Contemporary approaches to visual prostheses
Mirochnik, R. M., & Pezaris, J. S. (2019) · Military Medical Research · doi:10.1186/s40779-019-0206-9 · Cited by 58 · see citing works
Naycheva, L., Schatz, A., Röck, T., Willmann, G., Messias, A., Bartz-Schmidt, K. U., Zrenner, E., & Gekeler, F. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9612 · Cited by 55 · see citing works
Self-citationEnd-to-end optimization of prosthetic vision
de Ruyter van Steveninck, J., Güçlü, U., van Wezel, R., & van Gerven, M. (2022) · Journal of Vision · doi:10.1167/jov.22.2.20 · Cited by 54 · see citing works
Mobility and low contrast trip hazard avoidance using augmented depth
McCarthy, C., Walker, J. G., Lieby, P., Scott, A., & Barnes, N. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016003 · Cited by 49 · see citing works
Vision function testing for a suprachoroidal retinal prosthesis: effects of image filtering
Barnes, N., Scott, A. F., Lieby, P., Petoe, M. A., McCarthy, C., Stacey, A., Ayton, L. N., Sinclair, N. C., Shivdasani, M. N., Lovell, N. H., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036013 · Cited by 46 · see citing works
Advances in visual prostheses: engineering and biological challenges
Borda, E., & Ghezzi, D. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac812c · Cited by 44 · see citing works
Sabbah, N., Authie, C. N., Sanda, N., Mohand-Said, S., Sahel, J.-A., & Safran, A. B. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15392 · Cited by 45 · see citing works
Guo, T., Yang, C. Y., Tsai, D., Muralidharan, M., Suaning, G. J., Morley, J. W., Dokos, S., & Lovell, N. H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00168 · Cited by 43 · see citing works
Oculomotor behavior of blind patients seeing with a subretinal visual implant
Hafed, Z. M., Stingl, K., Bartz-Schmidt, K.-U., Gekeler, F., & Zrenner, E. (2016) · Vision Research · doi:10.1016/j.visres.2015.04.006 · Cited by 43 · see citing works
Self-citationElectrode-size dependent thresholds in subretinal neuroprosthetic stimulation
Corna, A., Herrmann, T., & Zeck, G. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac1c8 · Cited by 42 · see citing works
Optimization of return electrodes in neurostimulating arrays
Flores, T., Goetz, G., Lei, X., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036010 · Cited by 43 · see citing works
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42 · see citing works
Optical stimulation of neural tissue
Richardson, R. T., Ibbotson, M. R., Thompson, A. C., Wise, A. K., & Fallon, J. B. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0114 · Cited by 40 · see citing works
“demonstrated the ability to see and recognise large format letters [75].”
BackgroundParaskevoudi, N., & Pezaris, J. S. (2019) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2018.00073 · Cited by 39 · see citing works
The response of retinal neurons to high-frequency stimulation
Cai, C., Twyford, P., & Fried, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036009 · Cited by 38 · see citing works
Retinotopic to spatiotopic mapping in blind patients implanted with the Argus II retinal prosthesis
Caspi, A., Roy, A., Dorn, J. D., & Greenberg, R. J. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20398 · Cited by 32 · see citing works
Global activity shaping strategies for a retinal implant
Spencer, M. J., Kameneva, T., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf071 · Cited by 28 · see citing works
Spencer, T. C., Fallon, J. B., Thien, P. C., & Shivdasani, M. N. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19325 · Cited by 31 · see citing works
Semantic labeling for prosthetic vision
Horne, L., Alvarez, J., McCarthy, C., Salzmann, M., & Barnes, N. (2016) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2016.02.015 · Cited by 30 · see citing works
Esler, T. B., Kerr, R. R., Tahayori, B., Grayden, D. B., Meffin, H., & Burkitt, A. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0193598 · Cited by 28 · see citing works
The argus ii retinal prosthesis system
Bloch, E., & da Cruz, L. (2020) · Prosthesis · doi:10.5772/intechopen.84947 · Cited by 31 · see citing works
The Subretinal Implant ALPHA: Implantation and Functional Results
Zrenner, E., Bartz-Schmidt, K. U., Besch, D., Gekeler, F., Koitschev, A., Sachs, H. G., & Stingl, K. (2017) · Artificial Vision · doi:10.1007/978-3-319-41876-6_6 · Cited by 27 · see citing works
Self-citationChapter 1—restoring vision to the blind: the new age of implanted visual prostheses
(2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.7.3 · Cited by 21 · see citing works
Advances in neuroscience, not devices, will determine the effectiveness of visual prostheses
Abbasi, B., & Rizzo, J. F. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1887902 · Cited by 19 · see citing works
Reading visual braille with a retinal prosthesis
Lauritzen, T. Z., Harris, J., Mohand-Said, S., Sahel, J. A., Dorn, J. D., McClure, K., & Greenberg, R. J. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00168 · Cited by 22 · see citing works
Retinal prostheses: where to from here?
Allen, P. J. (2021) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.13950 · Cited by 20 · see citing works
Spectral distribution of local field potential responses to electrical stimulation of the retina
Wong, Y. T., Halupka, K., Kameneva, T., Cloherty, S. L., Grayden, D. B., Burkitt, A. N., Meffin, H., & Shivdasani, M. N. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036003 · Cited by 16 · see citing works
Corna, A., Ramesh, P., Jetter, F., Lee, M.-J., Macke, J. H., & Zeck, G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0679 · Cited by 18 · see citing works
Khalili Moghadam, G., Wilke, R., Suaning, G. J., Lovell, N. H., & Dokos, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073130 · Cited by 18 · see citing works
Cicione, R., Fallon, J. B., Rathbone, G. D., Williams, C. E., & Shivdasani, M. N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14754 · Cited by 17 · see citing works
Axonal stimulation affects the linear summation of single-point perception in three Argus II users
Hou, Y., Nanduri, D., Granley, J., Weiland, J. D., & Beyeler, M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad31c4 · Cited by 14 · see citing works
Paraskevoudi, N., & Pezaris, J. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-86996-4 · Cited by 16 · see citing works
A model of ganglion axon pathways accounts for percepts elicited by retinal implants
Beyeler, M., Nanduri, D., Weiland, J. D., Rokem, A., Boynton, G. M., & Fine, I. (2018) · doi:10.1101/453035 · Cited by 13 · see citing works
Deep reinforcement learning for task-based feature learning in prosthetic vision
White, J., Kameneva, T., & McCarthy, C. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856541 · Cited by 14 · see citing works
Borda, E., Gaillet, V., Airaghi Leccardi, M. J. I., Zollinger, E. G., Moreira, R. C., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac6d7e · Cited by 11 · see citing works
Improvement in reading performance through training with simulated thalamic visual prostheses
Rassia, K. E. K., & Pezaris, J. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-31435-0 · Cited by 13 · see citing works
Haji Ghaffari, D., Akwaboah, A. D., Mirzakhalili, E., & Weiland, J. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3138297 · Cited by 10 · see citing works
Ghaffari, D. H., Chang, Y.-C., Mirzakhalili, E., & Weiland, J. D. (2021) · 2021 10th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner49283.2021.9441437 · Cited by 10 · see citing works
Thorn, J. T., Chenais, N. A. L., Hinrichs, S., Chatelain, M., & Ghezzi, D. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5a5c · Cited by 11 · see citing works
End-to-end optimization of prosthetic vision
de Ruyter van Steveninck, J., Güçlü, U., van Wezel, R., & van Gerven, M. (2020) · doi:10.1101/2020.12.19.423601 · Cited by 54 · see citing works
“These neural interfaces can functionally replace the eye with a camera that is connected to the retina (Weiland, Liu, & Humayun, 2005; Zrenner et al., 2011), thalamus (Pezaris & Reid, 2007), or visual cortex (Beauchamp & Yoshor, 2020; Chen et al.”
Background
- Authors
- Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., Koch, J., Kusnyerik, A., Peters, T., Stingl, K., Sachs, H., Stett, A., Szurman, P., Wilhelm, B., & Wilke, R.
- Affiliations
- University of Tübingen (DE)
- Centre for Ophthalmology, University of Tübingen, Schleichstr. 12, 72076 Tübingen, Germany
- University of Regensburg (DE)
- Retina Implant AG, Gerhard-Kindler-Str. 8, 72770 Reutlingen, Germany
- Steinbeis Transfer Centre Eyetrial at the Centre for Ophthalmology, Schleichstr. 12-16, 72076 Tübingen, Germany
- Krankenhaus Dresden-Friedrichstadt (DE)
- Natural and Medical Sciences Institute (DE)
- Corresponding author
- Zrenner, Eberhart
- ORCID
- Venue
- Proceedings of the Royal Society B: Biological Sciences
- Publisher
- The Royal Society
- Published
- 2010-11-03
- Volume
- 278
- Issue
- 1711
- Pages
- 1489-1497
- ISSN
- 0080-4649 (ISSN-L)
- 0962-8452
- 1471-2954
- PMC
- PMC3081743
- OpenAlex
- W2158326388
- Cited by
- 819
- References
- 41
- Citations by year
- 2026: 11 · 2025: 17 · 2024: 18 · 2023: 26 · 2022: 42 · 2021: 35 · 2020: 57 · 2019: 47 · 2018: 65 · 2017: 69 · 2016: 71 · 2015: 63 · 2014: 96 · 2013: 79 · 2012: 68
- FWCI
- 25.70
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the Royal Society B Biological Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- subretinal implant, retinal prosthesis, inherited retinal disease, blindness, vision restoration, direct electrical stimulation, object recognition, letter reading, macula, visual perception
- MeSH terms
- Adult, Electrodes, Implanted, Female, Humans, Light, Male, Reading, Retina, Sensory Aids, Visual Perception, Implants, Experimental, Retinal Dystrophies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review