Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Influence of Disease Severity and Optic Disc Size on the Diagnostic Performance of Imaging Instruments in Glaucoma

Medeiros, Felipe A., Zangwill, Linda M., Bowd, Christopher, Sample, Pamela A., Weinreb, Robert N. · 2006 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To evaluate the influence of disease severity and optic disc size on the diagnostic accuracy of three imaging technologies for structural assessment in glaucoma: confocal scanning laser ophthalmoscopy, scanning laser polarimetry, and optical coherence tomography. METHODS: One hundred five patients with glaucoma and 61 normal subjects were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS). All individuals underwent imaging with the GDx Variable Corneal and Lens Compensator (VCC; Carl Zeiss Meditec, Inc., Dublin, CA), the Heidelberg Retina Tomograph II (HRT II; Heidelberg Engineering, GmbH, Dossenheim, Germany), and the Stratus OCT (Stratus OCT; Carl-Zeiss Meditec, Inc.) within a 6-month period. Severity of disease was based on the AGIS (Advanced Glaucoma Intervention Study) visual field score. To evaluate the influence of severity of glaucoma and optic disc size on the diagnostic accuracy of the imaging instruments, the sensitivities of the tests were fitted as a function of the AGIS score and disc area, by using logistic marginal regression models. RESULTS: The severity of visual field loss had a significant influence on the sensitivity of all imaging instruments. More severe disease was associated with increased sensitivity. This influence was similar among the three instruments. With regard to optic disc area, larger optic discs were associated with decreased sensitivity for the Stratus OCT parameter Average Thickness and the GDx VCC parameter Nerve Fiber Indicator, whereas small optic discs were associated with increased sensitivity. For the HRT II parameter Moorfields regression analysis classification, an inverse effect was observed. CONCLUSION: The diagnostic performances of the GDx VCC, HRT II, and Stratus OCT were significantly influenced by the severity of the disease and optic disc size. These covariates should be taken into account when comparing the performances of these tests for glaucoma diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.05-1133

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 162

Metadata

Authors
Medeiros, F. A., Zangwill, L. M., Bowd, C., Sample, P. A., & Weinreb, R. N.
Venue
Investigative Opthalmology & Visual Science
Published
2006-03-01
Volume
47
Issue
3
Pages
1008
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2066861991
Cited by
162
References
1
FWCI
17.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.