CoChat
Cited by 170

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Discrimination between Glaucomatous and Nonglaucomatous Eyes Using Quantitative Imaging Devices and Subjective Optic Nerve Head Assessment

Open access
DeLeo´n-Ortega, Julio E., Arthur, Stella N., McGwin, Gerald, Xie, Aiyuan, Monheit, Blythe E., Girkin, Christopher A. · 2006 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To compare the diagnostic ability of the confocal scanning laser ophthalmoscope (HRT-II; Heidelberg Engineering, Heidelberg, Germany), scanning laser polarimeter (GDx-VCC; Carl Zeiss Meditec, Inc., Dublin, CA), and optical coherence tomographer (StratusOCT, Carl Zeiss Meditec, Inc.) with subjective assessment of optic nerve head (ONH) stereophotographs in discriminating glaucomatous from nonglaucomatous eyes. METHODS: Data from 79 glaucomatous and 149 normal eyes of 228 subjects were included in the analysis. Three independent graders evaluated ONH stereophotographs. Receiver operating characteristic curves were constructed for each technique and sensitivity was estimated at 80% of specificity. Comparisons of areas under these curves (aROC) and agreement (kappa) were determined between stereophoto grading and best parameter from each technique. RESULTS: Stereophotograph grading had the largest aROC and sensitivity (0.903, 77.22%) in comparison with the best parameter from each technique: HRT-II global cup-to-disc area ratio (0.861, 75.95%); GDx-VCC Nerve Fiber Indicator (NFI; 0.836, 68.35%); and StratusOCT retinal nerve fiber layer (RNFL) thickness (0.844, 69.62%), ONH vertical integrated rim area (VIRA; 0.854, 73.42%), and macular thickness (0.815, 67.09%). The kappa between photograph grading and imaging parameters was 0.71 for StratusOCT-VIRA, 0.57 for HRT-II cup-to-disc area ratio, 0.51 for GDX-VCC NFI, 0.33 for StratusOCT RNFL, and 0.28 for StratusOCT macular thickness. CONCLUSIONS: Similar diagnostic ability was found for all imaging techniques, but none demonstrated superiority to subjective assessment of the ONH. Agreement between disease classification with subjective assessment of ONH and imaging techniques was greater for techniques that evaluate ONH topography than with techniques that evaluate RNFL parameters. A combination of subjective ONH evaluation with RNFL parameters provides additive information, may have clinical impact, and deserves to be considered in the design of future studies comparing objective techniques with subjective evaluation by general eye care providers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.05-1239

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
DeLeo´n-Ortega, J. E., Arthur, S. N., McGwin, G., Xie, A., Monheit, B. E., & Girkin, C. A.
Venue
Investigative Opthalmology & Visual Science
Published
2006-08-01
Volume
47
Issue
8
Pages
3374
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2039303389
Cited by
170
References
2
FWCI
11.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.