Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer
Abstract
PURPOSE: The Ocular Response Analyzer (ORA) is a new instrument that measures the corneal biomechanical response (corneal hysteresis, CH) to rapid indentation by an air jet. CH is the difference in applanation pressures (P1, P2) between the rising and falling phases of the air jet. The investigation had two parts: a characterization study and a validation study. In the characterization study, the purposes were to investigate the intraocular pressure (IOP)-dependence of CH and to characterize the performance of the ORA. In the validation study, the purposes were to investigate the association between CH and both age and central corneal thickness (CCT) and the agreement between ORA and Goldmann applanation tonometer (GAT) IOP measurements. METHODS: For the characterization study, data were collected from 105 untreated subjects (45 ocular hypertensive patients and 60 normal subjects; mean age, 60 years, range, 26-82). GAT and ORA measurements were performed before and after IOP lowering of one randomly selected eye with apraclonidine drops. The change in P1 and P2 (arbitrary units) in relation to change in GAT IOP was analyzed to calibrate the instrument. The relation between P1, P2, and CCT was explored and ORA IOP was derived from the analyses. For the validation study, ORA and GAT IOP and CCT were measured in 144 eyes of 144 untreated subjects (mean age, 58 years; range, 19-83). The characterization calculations were applied to the dataset and values of CH and ORA IOP were calculated. The relationship between CH and both subject age and CCT was determined. The associations between CH and CCT and between ORA and GAT IOPs, were investigated by linear regression analysis. The agreement between measuring devices was calculated. RESULTS: In the characterization study, P1 changed by 6.41 arbitrary units for every 1-mm Hg change in GAT IOP. CH (P1 - P2) changed by -1.60 arbitrary units for every 1-mm Hg change in GAT IOP. For each unit change in P2, P1 changed by 1.27 units. From this association a new IOP-independent corneal factor was derived [P1 - (P2/1.27)] and is termed the corneal constant factor (CCF; mm Hg). ORA IOP normalized for CCF was defined as P2 - CCF (mm Hg). The CCF (mm Hg) was associated with CCT (micrometers) and with age: CCF = [(0.036 . CCT) - (0.028 . age)] + 1.06 (adjusted r2 = 0.34; P < 0.0001 for CCT, P = 0.007 for age). Normalized ORA IOP measurements were not associated with CCT. GAT IOP was associated with CCT and CCF-more strongly with the latter: GAT IOP = (0.03 . CCT)+1.52 (r2 = 0.06, P = 0.002); GAT IOP = (0.65 . CCF) + 4.5 (r2 = 0.13, P < 0.0001). The mean difference (95% limits of agreement) between GAT and normalized ORA IOP was 0.1 (-6.6 to +6.8) mm Hg. CONCLUSIONS: The CCF describes an IOP-independent biomechanical property of the cornea that increases with thicker CCT and decreases with greater age. It is moderately strongly associated with CCT and yet explains more of the interindividual variation in GAT IOP than does CCT. Normalized ORA IOP measurements are not associated with CCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heijl, A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.10.1268 · Cited by 3,320
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311
WOLFS, R. C. W., KLAVER, C. C. W., VINGERLING, J. R., GROBBEE, D. E., HOFMAN, A., & de JONG, P. T. V. M. (1997) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71125-0 · Cited by 415
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056622 · Cited by 357
Collagen fibrils in the human corneal stroma: structure and aging.
Daxer, A., Misof, K., Grabner, B., Ettl, A. R., & Fratzl, P. (1998) · PubMed · Cited by 334
Ageing of the human corneal stroma: structural and biochemical changes
MALIK, N., MOSS, S., AHMED, N., FURTH, A., WALL, R., & MEEK, K. (1992) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/0925-4439(92)90041-k · Cited by 276
Feltgen, N. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.1.85 · Cited by 238
A comparison of four methods of tonometry: method agreement and interobserver variability
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056614 · Cited by 225
Kotecha, A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.075580 · Cited by 184
Self-citation
Cited by
Intraocular Pressure Fluctuation
Caprioli, J., & Coleman, A. L. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.10.031 · Cited by 505
Wells, A. P., Garway-Heath, D. F., Poostchi, A., Wong, T., Chan, K. C. Y., & Sachdev, N. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1556 · Cited by 265
Self-citationSurveillance for ocular hypertension: an evidence synthesis and economic evaluation.
Burr, J., Botello-Pinzon, P., Takwoingi, Y., Hernández, R., Vazquez-Montes, M., Elders, A., Asaoka, R., Banister, K., van der Schoot, J., Fraser, C., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16290 · Cited by 180
Self-citationWavelength-dependent ultraviolet induction of cyclobutane pyrimidine dimers in the human cornea
Mallet, J. D., & Rochette, P. J. (2013) · Photochemical & Photobiological Sciences · doi:10.1039/c3pp25408a · Cited by 65
Ultraviolet light-induced cyclobutane pyrimidine dimers in rabbit eyes
Mallet, J. D., & Rochette, P. J. (2011) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2011.00977.x · Cited by 29
Metadata
- Authors
- Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-12-01
- Volume
- 47
- Issue
- 12
- Pages
- 5337
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1999741464
- Cited by
- 423
- References
- 13
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer. https://app.cochat.ai/papers/10.1167/iovs.06-0557
- The paper
- Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F. (2006). Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response Analyzer. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.06-0557
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.