Measurement of Retinal Vascular Caliber: Issues and Alternatives to Using the Arteriole to Venule Ratio
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: The arteriole to venule ratio (AVR) is widely used in studies of the associations of retinal microvascular disease with systemic and ocular outcomes. This is a discussion of the limitations of AVR; a comparison of its predictive information with that of its components, arteriolar and venular caliber; and a description of a suggested alternative method of modeling arteriolar and venular calibers directly. METHODS: Data from the population-based Blue Mountains Eye Study were used to compare the predictive information in models using AVR with models using arteriolar and venular calibers directly. Determination was made of how the apparent relationship between vessel caliber and two systemic outcomes (blood pressure [BP] and white blood cell count [WBC]) was influenced by the choice of regression model. These findings were interpreted with reference to the known biological relationship among vessel calibers, BP, and WBC. RESULTS: Models using arteriolar and venular calibers directly had more predictive information than models using AVR. The apparent relationship of vessel caliber to BP and WBC differed substantially, depending on the model chosen. For example, after adjustment for age, sex, and other covariates, decreasing venular caliber was associated with higher systolic BP when modeled separately, but was associated with lower systolic BP when modeled simultaneously with arteriolar caliber. CONCLUSIONS: The findings suggest AVR provides less information with regards to predicting systemic outcomes than its two components. Modeling arteriolar and venular calibers separately could be biased by confounding, while modeling both simultaneously appears to provide unbiased, biologically plausible results. The use of this approach is recommended in future research relating retinal vascular caliber to systemic or ocular outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of age-related maculopathy in Australia
Mitchell, P., Smith, W., Attebo, K., & Wang, J. J. (1995) · Ophthalmology · doi:10.1016/s0161-6420(95)30846-9 · Cited by 1,062
Self-citation
Cited by
Quantification of biological aging in young adults
Belsky, D. W., Caspi, A., Houts, R., Cohen, H. J., Corcoran, D. L., Danese, A., Harrington, H., Israel, S., Levine, M. E., Schaefer, J. D., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1506264112 · Cited by 1,012
Ding, J., Strachan, M. W. J., Fowkes, F. G. R., Wong, T. Y., MacGillivray, T. J., Patton, N., Gardiner, T. A., Deary, I. J., & Price, J. F. (2011) · Diabetologia · doi:10.1007/s00125-011-2129-1 · Cited by 442
Self-citationCook, N. R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2008.523 · Cited by 429
Retinal Vascular Caliber: Systemic, Environmental, and Genetic Associations
Sun, C., Wang, J. J., Mackey, D. A., & Wong, T. Y. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.10.003 · Cited by 413
Self-citationMeta-analysis: Retinal Vessel Caliber and Risk for Coronary Heart Disease
McGeechan, K., Liew, G., Macaskill, P., Irwig, L., Klein, R., Klein, B. E. K., Wang, J. J., Mitchell, P., Vingerling, J. R., deJong, P. T. V. M., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-6-200909150-00005 · Cited by 337
Self-citation
Metadata
- Authors
- Liew, G., Sharrett, A. R., Kronmal, R., Klein, R., Wong, T. Y., Mitchell, P., Kifley, A., & Wang, J. J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2007-01-01
- Volume
- 48
- Issue
- 1
- Pages
- 52
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2058239891
- Cited by
- 148
- References
- 1
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.